Honeywell 1202g2 Manual
Here you can view all the pages of manual Honeywell 1202g2 Manual. The Honeywell manuals for Scanner are available online for free. You can easily download all the documents as PDF.
Page 121
8 - 3 Codabar Concatenation Codabar supports symbol concatenation. When you enable concatenation, the scanner looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two messages are concatenated into one with the “D” characters omitted. Select Require to prevent the scanner from decoding a single “D” Codabar symbol without its companion. This selection has no effect on Codabar symbols without Stop/Start D characters. Validate...
Page 122
8 - 4 Concatenation Timeout When searching for bar codes during concatenation, you may wish to set a delay used to find the next bar code. Set the length (in milliseconds) for this delay by scanning the following bar code, then setting the timeout (from 1-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 750. Codabar Redundancy If you are encountering errors when reading Codabar bar codes, you may want to adjust the redundancy count. Redun- dancy...
Page 123
8 - 5 Code 39 < Default All Code 39 Settings > Code 39 On/Off Code 39 Start / Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/ Stop characters. Default = Don’t Transmit. Code 39 Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character. When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 bar codes...
Page 124
8 - 6 Code 39 Redundancy If you are encountering errors when reading Code 39 bar codes, you may want to adjust the redundancy count. Redun- dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the Code 39 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back...
Page 125
8 - 7 Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = Off. Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9. NUL %UDLE $PSP SPACE00@%VPP‘%Wp+P SOH $A DC1 $Q!/A11AAQQa+Aq+Q STX $B DC2 $R“/B22BBRRb+Br+R ETX $C...
Page 126
8 - 8 Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > Interleaved 2 of 5 On/Off NULL Characters Interleaved 2 of 5 requires an even number of characters. When an odd number of characters is present, it is due to NULL characters embedded in the bar code. Scan the On bar code below to decode this type of Interleaved 2 of 5 bar code. Default = Off. Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is...
Page 127
8 - 9 Interleaved 2 of 5 Redundancy If you are encountering errors when reading Interleaved 2 of 5 bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the Interleaved 2 of 5 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the...
Page 128
8 - 10 When Check Digit is set to Validate, but Don’t Transmit, the unit only reads NEC 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data. When Check Digit is set to Validate and Transmit, the scanner only reads NEC 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit. NEC 2 of 5 Redundancy If you are encountering errors when reading NEC 2 of 5 bar codes, you may want...
Page 129
8 - 11 Code 93 < Default All Code 93 Settings > Code 93 On/Off Code 93 Redundancy If you are encountering errors when reading Code 93 bar codes, you may want to adjust the redundancy count. Redun- dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the Code 93 Redundancy bar code below, then scan a redundancy count...
Page 130
8 - 12 Straight 2 of 5 Industrial (three-bar start/stop) Straight 2 of 5 Industrial On/Off Straight 2 of 5 Industrial Redundancy If you are encountering errors when reading Straight 2 of 5 Industrial bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redun- dancy, scan...