Page 71

3 - 19
When the scanner goes out of range, 15 attempts are made to link to the base unit.  Each attempt consists of approximately 
5 seconds of active time followed by 3 seconds of idle time.  After 15 cycles (8*15 =120), or about 2 minutes, the scanner 
stops trying to connect to the base, but retains any bar codes that may have been saved in batch mode.  After one hour, the 
scanner powers off and batch mode data is lost.
Auto Reconnect Mode set to 0
Maximum Link Attempts set to 15
Other values at...

Page 72

3 - 20 

Page 73

4 - 1
4
Cordless System Operation (Voyager 1202g-BF)
Note: This chapter applies only to Voyager 1202g-BF cordless scanning systems (PN: 1202G-BF).  It does not apply to corded 
or Voyager 1202g scanners.  See Cordless System Operation (Voyager 1202g) on page 3-1 for Voyager 1202g scanners.
How the Charge and Communications Base Works
A charge and communications base provides the link between the cordless scanner and the host system.  The base contains an 
interface assembly and an RF communication...

Page 74

4 - 2
When data is scanned, the data is sent to the host system via the base.  The cordless scanner recognizes data acknowledge-
ment (ACK) from the base.  If it cannot be determined that the data has been properly sent to the base, the scanner issues an 
error indication.  You must then check to see if the scanned data was received by the host system.  If data has not been properly 
sent to the host, additional scanner configurations may be needed.  Contact Technical Support (see page -iii) for...

Page 75

4 - 3
Page Button
When you press the Page button on the base, the scanner associated with that base will begin beeping (3 short and 1 long 
beep).  If you press the button on a scanner that is beeping in response, or press the Page button on the base a second 
time, the scanner will stop beeping.  See Pagingon page 4-5 for further information about Page Button settings. 
About the Instant Charge Pack
Power is supplied to the cordless scanner by a rechargeable instant charge pack that is integrated in the...

Page 76

4 - 4
Base LED Sequences and Meaning
The base contains a red LED that indicate the status of the unit and verifies its communication with the host system.  The 
base also has a green LED that indicates the scanner instant charge pack charge condition.  The red LED and the green 
LED both flash when a link is established.  
Base Power Communication Indicator
To display the power indicator on the base, scan the Base Power Communication Indicator On bar code.  To turn off the 
power indicator, scan the Off...

Page 77

4 - 5
Scanning While in Base Cradle
If you want to be able to scan bar codes while the scanner is in the base, scan the following Scanning in Cradle On bar code.  
If you want to only allow scanning when the scanner is out of the base, scan Scanning in Cradle Off.  Default = Scanning in 
Cradle On.
Note: When Scanning in Cradle Off is selected, the scanner will not scan any bar codes while it is in the base.  It will only scan 
when removed from the base.
Paging
Paging Mode
By default, the paging button...

Page 78

4 - 6
Scanner Address
Scan the following bar code to determine the address of the scanner you are using.
Base Address
Scan the following bar code to determine the address of the base you are using.
Scanner Modes
The Voyager 1202g-BF is only capable of working with the CCB00-010BT-01N-BF base.
Charge Only Mode
There may be times when you want to charge your scanner, but not link to the base.  For example, if a scanner is linked to 
a Bluetooth device and you need to charge the scanner, but want to retain...

Page 79

4 - 7
Locked Link Mode - Single Scanner
If you link a scanner to a base using the Locked Link Mode, other scanners are blocked from being linked if they are 
inadvertently placed into the base.  If you do place a different scanner into a base, it will charge the scanner, but the 
scanner will not be linked. 
To use a different scanner, you need to unlink the original scanner by scanning the Unlink Scanner bar code. (See 
Scanner Modes, page 4-6.)
Open Link Mode - Single Scanner
When newly shipped or...

Page 80

4 - 8
The sounds are as follows:
Alarm Duration
To set the length of time you want the Out-of-Range alarm to sound, scan the following bar code and then set the time-out 
duration (from 0-3000 seconds) by scanning digits on the Programming Chart inside the back cover, then scanning Save.  
Default = 1 sec.
Using the Scanner with Bluetooth Devices
The scanner can only be used with the CCB00-010BT-01N-BF base.
Minimizing Bluetooth/ISM Band Network Activity
The following settings can help you customize the...