6 - 1 6 Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string. Prefix and Suffix characters are data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or...
Page 102
6 - 2 Example: Add a Tab Suffix to All Symbologies Step 1.Scan Add Suffix. Step 2.Scan 9, 9 from the Programming Chart inside the back cover of this manual to apply this suffix to all symbologies. Step 3.Scan 0, 9 from the Programming Chart inside the back cover of this manual. This corresponds with the hex value for a horizontal tab, shown in the ASCII Conversion Chart (Code Page 1252), beginning on page A-2. Step 4.Scan Save, or scan Discard to exit without saving. To Clear One or All Prefixes or...
Page 103
6 - 3 Transmit Alternate Extended ASCII Characters You may need to emulate special keyboard functions, such as up or down arrows, Alt/Make or Alt/Break commands, that are not supported in the Extended ASCII Character table. Refer to the Alternate Extended ASCII Characters table, below, for a range of keyboard function keys and corresponding decimal and hex characters. If you scan the Transmit Alternate Extended ASCII code, any hex entries in a prefix or suffix will result in the corresponding...
Page 104
6 - 4 Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Symbology Charts starting on page A-1. When the scan- ner is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted. Default = Enable. Communication Check Character To enhance security, you can specify the transmission type of a check character;...
Page 105
6 - 5 Intercharacter, Interfunction, and Intermessage Delays Some terminals drop information (characters) if data comes through too quickly. Intercharacter, interfunction, and intermessage delays slow the transmission of data, increasing data integrity. Intercharacter Delay An intercharacter delay of up to 327675 milliseconds (in 5ms increments) may be placed between the transmission of each character of scanned data. Scan the following Intercharacter Delay bar code, then scan the number of 5ms...
Page 106
6 - 6 Interfunction Delay An interfunction delay of up to 327675 milliseconds (in 5ms increments) may be placed between the transmission of each segment of the message string. Scan the following Interfunction Delay bar code, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual. To remove this delay, scan the Interfunction Delay bar code, then set the number of delays to 0. Scan the Save bar code using the Programming Chart inside...
Page 107
7 - 1 7 Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to alter the output. Default Data Format setting = None. Normally, when you scan a bar code, it gets outputted automatically; however when you create a format, you must use a “send” command (see...
Page 108
7 - 2 from the Programming Chart inside the back cover of this manual. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.) Step 6. Editor Commands Refer to (page 7-3). Scan the symbols that represent the command you want to enter. Step 7.Scan Save to save your data format, or Discard to exit without saving your changes. Other Programming Selections Clear One Data Format This deletes one data format for one symbology. If you are clearing the primary...
Page 109
7 - 3 Data Format Editor Commands Send Commands Send all characters F1 Include in the output message all of the characters from the input message, starting from current cursor position, followed by an insert character. Syntax = F1xx where xx stands for the insert character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252), page A-2 for decimal, hex and character codes. Send a number of characters F2 Include in the output message a number of characters followed by an...
Page 110
7 - 4 The data is output as: 1234567890 ABCDEFGHIJ Send all characters up to a particular character F3 Include in the output message all characters from the input message, starting with the character at the current cursor position and continuing to, but not including, the search character “ss,” followed by an insert character. The cursor is moved forward to the “ss” character. Syntax = F3ssxx where ss stands for the search character’s hex value for its ASCII code, and xx stands for the insert...