Honeywell 1202g2 Manual
Here you can view all the pages of manual Honeywell 1202g2 Manual. The Honeywell manuals for Scanner are available online for free. You can easily download all the documents as PDF.
Page 91
5 - 9 CodeGate When CodeGate is On, the button is used to allow decoded data to be transmitted to the host system. The scanner remains on, scanning and decoding bar codes, but the bar code data is not transmitted until the button is pressed. When CodeGate is Off, bar code data is transmitted when it is decoded. Default = CodeGate Off in-Stand, CodeGate On Out-of- Stand. Button Function Note: Button Function applies only to the Voyager 1202. It is not supported in the Voyager 1200. When Button...
Page 92
5 - 10 End Object Detection After Good Read After a bar code is successfully detected and read from the scanner, the laser can be programmed either to remain on and scanning, or to turn off. When End Object Detection After Good Readis enabled, the laser turns off and stops scanning after a good read. If you scan Do Not End Object Detection After Good Read, the laser remains on after a good read. Default = End Object Detection After Good Read. * Object Detection Mode On In-Stand * Object Detection...
Page 93
5 - 11 Object Detection Laser Timeout You can set a timeout for the length of time the laser remains on and attempting to decode bar codes after an object is detected. Set the length (in milliseconds) for a timeout by scanning the following bar code, then setting the timeout (from 1- 65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 5000 ms. Object Detection Distance When you are using Object Detection Mode, you can set the distance range for detecting...
Page 94
5 - 12 Activation Character This sets the character used to trigger scanning when using Character Activation Mode. On the ASCII Conversion Chart (Code Page 1252), page A-2, find the hex value that represents the character you want to use to trigger scanning. Scan the following bar code, then use the Programming Chart to read the alphanumeric combination that represents that ASCII character. Scan Save to finish. End Character Activation After Good Read After a bar code is successfully detected and...
Page 95
5 - 13 Deactivation Character This sets the character used to terminate scanning when using Character Deactivation Mode. On the ASCII Conversion Chart (Code Page 1252), page A-2, find the hex value that represents the character you want to use to terminate scanning. Scan the following bar code, then use the Programming Chart to read the alphanumeric combination that represents that ASCII character. Scan Save to finish. Reread Delay This sets the time period before the scanner can read the same bar...
Page 96
5 - 14 Output Sequence Overview Output Sequence Editor This programming selection allows you to program the scanner to output data (when scanning more than one symbol) in whatever order your application requires, regardless of the order in which the bar codes are scanned. Reading the Default Sequence symbol programs the scanner to the following Universal values. These are the defaults. Be certain you want to delete or clear all formats before you read the Default Sequence symbol. Note: If CodeGate...
Page 97
5 - 15 SEQBLK sequence editor start command 62 code identifier for Code 39 9999 code length that must match for Code 39, 9999 = all lengths 41 start character match for Code 39, 41h = “A” FF termination string for first code 6A code identifier for Code 128 9999 code length that must match for Code 128, 9999 = all lengths 42 start character match for Code 128, 42h = “B” FF termination string for second code 69 code identifier for Code 93 9999 code length that must match for Code 93, 9999 = all lengths 43...
Page 98
5 - 16 Output Sequence Editor Sequence Timeout You may wish to set the maximum time between bar code scans in an output sequence. If that maximum time is not met, the output sequence operation is terminated. Set the length (in milliseconds) for a timeout by scanning the following bar code, then setting the timeout (from 1-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 5000 msec. Sequence Match Beeper By default, the scanner beeps when a sequence...
Page 99
5 - 17 Require Output Sequence When an output sequence is Required, all output data must conform to an edited sequence or the scanner will not transmit the output data to the host device. When it’s On/Not Required, the scanner will attempt to get the output data to conform to an edited sequence but, if it cannot, the scanner transmits all output data to the host device as is. When the output sequence is Off, the bar code data is output to the host as the scanner decodes it. Default = Off. No Read...