Page 161

8 - 43
EAN/JAN-8 Addenda Separator
When this feature is On, there is a space between the data from the bar code and the data from the addenda.  When turned 
Off, there is no space.  Default = Off.
EAN/JAN-8 Redundancy
If you are encountering errors when reading EAN/JAN-8 bar codes, you may want to adjust the redundancy count.  Redun-
dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.  
Note that the higher the redundancy count, the longer...

Page 162

8 - 44
When Check Character is set to Validate Type 10/11, but Don’t Transmit, the unit will only read MSI bar codes printed 
with the specified type check character(s), but will not transmit the check character(s) with the scanned data.
MSI Redundancy
If you are encountering errors when reading MSI bar codes, you may want to adjust the redundancy count.  Redundancy 
adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.  Note that 
the higher the...

Page 163

8 - 45
MSI Message Length
Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
information.  Minimum and Maximum lengths = 1-80.   Minimum Default = 3, Maximum Default = 80.
Plessey Code
< Default All Plessey Code Settings >
Plessey Code On/Off
Plessey Check Character
No Check Character indicates that the scanner reads and transmits bar code data with or without a check character.
When Check Character is set to Validate, but Don’t...

Page 164

8 - 46
Plessey Redundancy
If you are encountering errors when reading Plessey bar codes, you may want to adjust the redundancy count.  Redun-
dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.  
Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redundancy, scan 
the Plessey Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart 
inside the...

Page 165

8 - 47
redundancy, scan the GS1 DataBar Omnidirectional Redundancy bar code below, then scan a redundancy count 
between 0 and 10 on the Programming Chart inside the back cover of this manual.  Then scan the Save bar code.  Default 
= 0.
GS1 DataBar Limited
< Default All GS1 DataBar Limited Settings >
GS1 DataBar Limited On/Off
GS1 DataBar Limited Redundancy
If you are encountering errors when reading GS1 DataBar Limited bar codes, you may want to adjust the redundancy 
count.  Redundancy adjusts the...

Page 166

8 - 48
GS1 DataBar Expanded
< Default All GS1 DataBar Expanded Settings >
GS1 DataBar Expanded On/Off
GS1 DataBar Expanded Redundancy
If you are encountering errors when reading GS1 DataBar Expanded bar codes, you may want to adjust the redundancy 
count.  Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number 
of errors.  Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redun-
dancy, scan the...

Page 167

8 - 49
GS1 Emulation
The scanner can automatically format the output from any GS1 data carrier to emulate what would be encoded in an equivalent 
GS1-128 or GS1 DataBar  symbol.  GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, GS1-128, and 
GS1-128 DataBar and GS1 Composites.  (Any application that accepts GS1 data can be simplified since it only needs to recog-
nize one data carrier type.)
If GS1-128 Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8, EAN13) are expanded...

Page 168

8 - 50
China Post (Hong Kong 2 of 5)

China Post (Hong Kong 2 of 5) On/Off
China Post (Hong Kong 2 of 5) Redundancy
If you are encountering errors when reading China Post (Hong Kong 2 of 5) bar codes, you may want to adjust the 
redundancy count.  Redundancy adjusts the number of times a bar code is decoded before transmission, which may 
reduce the number of errors.  Note that the higher the redundancy count, the longer it will take to decode the bar code.  
To adjust the redundancy, scan the China Post...

Page 169

9 - 1
9
Utilities
To Add a Test Code I.D. Prefix to All Symbologies
This selection allows you to turn on transmission of a Code I.D. before the decoded symbology.  (See the Symbology Charts, 
beginning on page A-1) for the single character code that identifies each symbology.)  This action first clears all current prefixes, 
then programs a Code I.D. prefix for all symbologies.  This is a temporary setting that will be removed when the unit is power 
cycled.
Show Software Revision
Scan the bar codes...

Page 170

9 - 2
EZConfig-Scanning Introduction
EZConfig-Scanning provides a wide range of PC-based programming functions that can be performed on a scanner connected 
to your PC.  EZConfig-Scanning allows you to download upgrades to the scanners firmware, change programmed parameters, 
and create and print programming bar codes.  Using EZConfig-Scanning, you can even save/open the programming parameters 
for a scanner.  This saved file can be e-mailed or, if required, you can create a single bar code that contains...