Home > Honeywell > Scanner > Honeywell 1202g2 Manual

Honeywell 1202g2 Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell 1202g2 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							8 - 43
    EAN/JAN-8 Addenda Separator
    When this feature is On, there is a space between the data from the bar code and the data from the addenda.  When turned 
    Off, there is no space.  Default = Off.
    EAN/JAN-8 Redundancy
    If you are encountering errors when reading EAN/JAN-8 bar codes, you may want to adjust the redundancy count.  Redun-
    dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.  
    Note that the higher the redundancy count, the longer it will take to decode the ba code.  To adjust the redundancy, scan the 
    EAN/JAN-8 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart 
    inside the back cover of this manual.  Then scan the Save bar code.  Default = 0.
    MSI
    
    MSI On/Off
    MSI Check Character
    Different types of check characters are used with MSI bar codes.  You can program the scanner to read MSI bar codes with 
    Type 10 check characters.  Default = Validate Type 10, but Don’t Transmit.
    When Check Character is set to Validate Type 10/11 and Transmit, the scanner will only read MSI bar codes printed with 
    the specified type check character(s), and will transmit the character(s) at the end of the scanned data.
    On
    *  Off
    EAN/JAN-8 Redundancy
    On
    * Off 
    						
    							8 - 44
    When Check Character is set to Validate Type 10/11, but Don’t Transmit, the unit will only read MSI bar codes printed 
    with the specified type check character(s), but will not transmit the check character(s) with the scanned data.
    MSI Redundancy
    If you are encountering errors when reading MSI bar codes, you may want to adjust the redundancy count.  Redundancy 
    adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.  Note that 
    the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redundancy, scan the MSI 
    Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back 
    cover of this manual.  Then scan the Save bar code.  Default = 0.
    *  Validate Type 10, but Don’t 
    Transmit
    Validate Type 10 and Transmit
    Validate 2 Type 10 Characters, 
    but Don’t Transmit
    Validate 2 Type 10 Characters 
    and Transmit
    Validate Type 11 then Type 10 
    Character, but Don’t Transmit
    Validate Type 11 then 
    Type 10 Character and Transmit
    Disable MSI Check Characters
    MSI Redundancy 
    						
    							8 - 45
    MSI Message Length
    Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
    information.  Minimum and Maximum lengths = 1-80.   Minimum Default = 3, Maximum Default = 80.
    Plessey Code
    < Default All Plessey Code Settings >
    Plessey Code On/Off
    Plessey Check Character
    No Check Character indicates that the scanner reads and transmits bar code data with or without a check character.
    When Check Character is set to Validate, but Don’t Transmit, the unit only reads Plessey bar codes printed with a check 
    character, but will not transmit the check character with the scanned data.  
    When Check Character is set to Validate and Transmit, the scanner only reads Plessey bar codes printed with a check 
    character, and will transmit this character at the end of the scanned data.  Default = No Check Character.
    Minimum Message Length
    Maximum Message Length
    On
    * Off
    *  No Check Character
    Validate, but Don’t Transmit
    Validate and Transmit 
    						
    							8 - 46
    Plessey Redundancy
    If you are encountering errors when reading Plessey bar codes, you may want to adjust the redundancy count.  Redun-
    dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.  
    Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redundancy, scan 
    the Plessey Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart 
    inside the back cover of this manual.  Then scan the Save bar code.  Default = 0.
    Plessey Message Length
    Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
    information.  Minimum and Maximum lengths = 1-80.   Minimum Default = 3, Maximum Default = 80.
    GS1 DataBar Omnidirectional
    < Default All GS1 DataBar Omnidirectional Settings >
    GS1 DataBar Omnidirectional On/Off
    GS1 DataBar Omnidirectional Redundancy
    If you are encountering errors when reading GS1 DataBar Omnidirectional bar codes, you may want to adjust the redun-
    dancy count.  Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the 
    number of errors.  Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the 
    Plessey Redundancy
    Minimum Message Length
    Maximum Message Length
    * On
    Off 
    						
    							8 - 47
    redundancy, scan the GS1 DataBar Omnidirectional Redundancy bar code below, then scan a redundancy count 
    between 0 and 10 on the Programming Chart inside the back cover of this manual.  Then scan the Save bar code.  Default 
    = 0.
    GS1 DataBar Limited
    < Default All GS1 DataBar Limited Settings >
    GS1 DataBar Limited On/Off
    GS1 DataBar Limited Redundancy
    If you are encountering errors when reading GS1 DataBar Limited bar codes, you may want to adjust the redundancy 
    count.  Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number 
    of errors.  Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redun-
    dancy, scan the GS1 DataBar Limited Redundancy bar code below, then scan a redundancy count between 0 and 10 on 
    the Programming Chart inside the back cover of this manual.  Then scan the Save bar code.  Default = 0.
    GS1 DataBar Omnidirectional 
    Redundancy
    * On
    Off
    GS1 DataBar Limited 
    Redundancy 
    						
    							8 - 48
    GS1 DataBar Expanded
    < Default All GS1 DataBar Expanded Settings >
    GS1 DataBar Expanded On/Off
    GS1 DataBar Expanded Redundancy
    If you are encountering errors when reading GS1 DataBar Expanded bar codes, you may want to adjust the redundancy 
    count.  Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number 
    of errors.  Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redun-
    dancy, scan the GS1 DataBar Expanded Redundancy bar code below, then scan a redundancy count between 0 and 10 
    on the Programming Chart inside the back cover of this manual.  Then scan the Save bar code.  Default = 0.
    GS1 DataBar Expanded Message Length
    Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
    information.  Minimum and Maximum lengths = 1-80.   Minimum Default = 3, Maximum Default = 80.
    Trioptic Code
    Trioptic Code is used for labeling magnetic storage media.
    * On
    Off
    GS1 DataBar Expanded 
    Redundancy
    Minimum Message Length
    Maximum Message Length
    On 
    						
    							8 - 49
    GS1 Emulation
    The scanner can automatically format the output from any GS1 data carrier to emulate what would be encoded in an equivalent 
    GS1-128 or GS1 DataBar  symbol.  GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, GS1-128, and 
    GS1-128 DataBar and GS1 Composites.  (Any application that accepts GS1 data can be simplified since it only needs to recog-
    nize one data carrier type.)
    If GS1-128 Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8, EAN13) are expanded out to 16 digits.  If the AIM ID 
    is enabled, the value will be the GS1-128 AIM ID, ]C1 (see Symbology Charts on page A-1).
    If GS1 DataBar Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8, EAN13) are expanded out to 16 digits.  If the AIM 
    ID is enabled, the value will be the GS1-DataBar AIM ID, ]em (see Symbology Charts on page A-1).
    If GS1 Code Expansion Off is scanned, retail code expansion is disabled, and UPC-E expansion is controlled by the UPC-E0 
    Expand (page 8-30) setting.  If the AIM ID is enabled, the value will be the GS1-128 AIM ID, ]C1 (see Symbology Charts on 
    page A-1).
    If EAN8 to EAN13 Conversion is scanned, all EAN8 bar codes are converted to EAN13 format.  
    Default = GS1 Emulation Off.
    Postal Codes
    The following lists linear postal codes.  Any combination of linear postal code selections can be active at a time.  
    * Off
    GS1-128 Emulation
    GS1 DataBar Emulation
    GS1 Code Expansion Off
    EAN8 to EAN13 Conversion
    * GS1 Emulation Off 
    						
    							8 - 50
    China Post (Hong Kong 2 of 5)
    
    China Post (Hong Kong 2 of 5) On/Off
    China Post (Hong Kong 2 of 5) Redundancy
    If you are encountering errors when reading China Post (Hong Kong 2 of 5) bar codes, you may want to adjust the 
    redundancy count.  Redundancy adjusts the number of times a bar code is decoded before transmission, which may 
    reduce the number of errors.  Note that the higher the redundancy count, the longer it will take to decode the bar code.  
    To adjust the redundancy, scan the China Post (Hong Kong 2 of 5) Redundancy bar code below, then scan a redun-
    dancy count between 0 and 10 on the Programming Chart inside the back cover of this manual.  Then scan the Save 
    bar code.  Default = 0.
    China Post (Hong Kong 2 of 5) Message Length
    Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for addi-
    tional information.  Minimum and Maximum lengths = 1-80.   Minimum Default = 3, Maximum Default = 80.
    On
    * Off
    China Post (Hong Kong 2 of 5) 
    Redundancy
    Minimum Message Length
    Maximum Message Length 
    						
    							9 - 1
    9
    Utilities
    To Add a Test Code I.D. Prefix to All Symbologies
    This selection allows you to turn on transmission of a Code I.D. before the decoded symbology.  (See the Symbology Charts, 
    beginning on page A-1) for the single character code that identifies each symbology.)  This action first clears all current prefixes, 
    then programs a Code I.D. prefix for all symbologies.  This is a temporary setting that will be removed when the unit is power 
    cycled.
    Show Software Revision
    Scan the bar codes below to output the current software revision, unit serial number, and other product information for the scan-
    ner or base.
    Show Data Format
    Scan the bar code below to show current data format settings.
    Test Menu
    When you scan the Test Menu On code, then scan a programming code in this manual, the scanner displays the content of a 
    programming code.  The programming function will still occur, but in addition, the content of that programming code is output to 
    the terminal.  
    Note: This feature should not be used during normal scanner operation.
    Add Code I.D. Prefix to
    All Symbologies (Temporary)
    Show Revision of Scanner
    Show Revision of Base
    Data Format Settings
    DFMBK3?.
    On
    * Off 
    						
    							9 - 2
    EZConfig-Scanning Introduction
    EZConfig-Scanning provides a wide range of PC-based programming functions that can be performed on a scanner connected 
    to your PC.  EZConfig-Scanning allows you to download upgrades to the scanners firmware, change programmed parameters, 
    and create and print programming bar codes.  Using EZConfig-Scanning, you can even save/open the programming parameters 
    for a scanner.  This saved file can be e-mailed or, if required, you can create a single bar code that contains all the customized 
    programming parameters and mail or fax that bar code to any location.  Users in other locations can scan the bar code to load in 
    the customized programming. 
    EZConfig-Scanning Operations
    The EZConfig-Scanning software performs the following operations:
    Scan Data
    Scan Data allows you to scan bar codes and display the bar code data in a window.  Scan Data lets you send serial 
    commands to the scanner and receive scanner response that can be seen in the Scan Data window.  The data dis-
    played in the Scan Data window can either be saved in a file or printed. 
    Configure
    Configure displays the programming and configuration data of the scanner.  The scanners programming and configu-
    ration data is grouped into different categories.  Each category is displayed as a tree item under the “Configure” tree 
    node in the application explorer.  When one of these tree nodes is clicked, the right-hand side is loaded with the 
    parameters form belonging to that particular category.  The Configure tree option has all the programming and config-
    uration parameters specified for a scanner.  You can set or modify these parameters as required.  You can later write 
    the modified settings to the scanner, or save them to a dcf file. 
    Installing EZConfig-Scanning from the Web
    Note: EZConfig-Scanning requires .NET software.  If .NET is not installed on your PC, you will be prompted to install it 
    during the EZConfig-Scanning installation.
    1. Access the Honeywell web site at
     www.honeywellaidc.com
    2. Click on the Products tab.  Under Software, select Device Management.
    3. Click on EZConfig-Device Configuration Software.
    4. Click on the Software tab.  Select EZConfig Cloud For Scanning (online version, must register for access) or 
    EZConfig for Scanning (to install on your PC, follow the next steps).
    5. To install on your PC, when prompted, select Save File, and save the files to the c:\windows	emp directory.  
    6. Once you have finished downloading the file, exit the web site.
    7. Using Explorer, go to the c:\windows\temp file.
    8. Double click on the Setup.exe file.  Follow the screen prompts to install the EZConfig-Scanning program.
    9. If you’ve selected the defaults during installation, you can click on Start Menu-All Programs-Honeywell-EZConfig-
    Scanning and select EZConfig for your browser. 
    						
    All Honeywell manuals Comments (23)