Home > Honeywell > Scanner > Honeywell 1202g2 Manual

Honeywell 1202g2 Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell 1202g2 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							8 - 33
    UPC-E0 Addenda Separator
    When this feature is On, there is a space between the data from the bar code and the data from the addenda.  When turned 
    Off, there is no space.  Default = Off.
    UPC-E0 Redundancy
    If you are encountering errors when reading UPC-E0 bar codes, you may want to adjust the redundancy count.  Redun-
    dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.  
    Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redundancy, scan 
    the UPC-E0 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart 
    inside the back cover of this manual.  Then scan the Save bar code.  Default = 1.
    EAN/JAN-13
    
    EAN/JAN-13 On/Off
    Convert UPC-A to EAN-13
    When UPC-A Converted to EAN-13 is selected, UPC-A bar codes are converted to 13 digit EAN-13 codes by adding a 
    zero to the front.  When Do not Convert UPC-A is selected, UPC-A codes are read as UPC-A.
    On
    * Off
    UPC-E0 Redundancy
    *  On
    Off
    UPC-A Converted to EAN-13 
    						
    							8 - 34
    EAN/JAN-13 Check Digit
    This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not.  
    Default = On.
    EAN/JAN-13 Addenda
    This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data.  Default = Off for both 2 Digit and 5 Digit 
    Addenda.
    EAN/JAN-13 Addenda Required
    When Required is scanned, the scanner will only read EAN/JAN-13 bar codes that have addenda.  Default = Not Required.
    * Do not Convert  UPC-A
    *  On
    Off
    2 Digit Addenda On
    * 2 Digit Addenda Off
    5 Digit Addenda On
    * 5 Digit Addenda Off
    Required 
    						
    							8 - 35
    EAN-13 Beginning with 2 Addenda Required
    This setting programs the scanner to require a 2 digit addenda only on EAN-13 bar codes that begin with a “2.”  The follow-
    ing settings can be programmed:
    Require 2 Digit Addenda:  All EAN-13 bar codes that begin with a “2” must have a 2 digit addendum.  The EAN-13 bar 
    code with the 2 digit addendum is then transmitted as a single, concatenated bar code.  If a 2 digit addendum is not found 
    within the Addenda Timeout period, the EAN-13 bar code is discarded.
    Note: if you are using EAN-13 Beginning with 290 Addenda Required (page 8-35), that setting will take precedence over 
    this one.
    Don’t Require 2 Digit Addenda:  If you have selected Require 2 Digit Addenda, and you want to disable this feature, 
    scan Don’t Require 2 Digit Addenda.  EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/
    JAN-13 Addenda Required.
    Default = Don’t Require 2 Digit Addenda.
    EAN-13 Beginning with 290 Addenda Required
    This setting programs the scanner to require a 5 digit addenda only on EAN-13 bar codes that begin with “290.”  The follow-
    ing settings can be programmed:
    Require 5 Digit Addenda:  All EAN-13 bar codes that begin with “290” must have a 5 digit addendum.  The EAN-13 bar 
    code with the 5 digit addendum is then transmitted as a single, concatenated bar code.  If a 5 digit addendum is not found 
    within the Addenda Timeout period, the EAN-13 bar code is discarded.
    Note: if you are using EAN-13 Beginning with 2 Addenda Required (page 8-35), this setting will take precedence.
    Don’t Require 5 Digit Addenda:  If you have selected Require 5 Digit Addenda, and you want to disable this feature, 
    scan Don’t Require 5 Digit Addenda.  EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/
    JAN-13 Addenda Required.
    Default = Don’t Require 5 Digit Addenda.
    *  Not Required
    * Don’t Require  2 Digit 
    Addenda
    Require  2 Digit Addenda
    * Don’t Require  5 Digit 
    Addenda
    Require  5 Digit Addenda 
    						
    							8 - 36
    EAN-13 Beginning with 378/379 Addenda Required 
    This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 bar 
    codes that begin with a “378” or “379.”  The following settings can be programmed:
    Require Addenda:  All EAN-13 bar codes that begin with a “378” or “379” must have a 2 digit addenda, a 5 digit addenda, 
    or a combination of these addenda.  The EAN-13 bar code with the addenda is then transmitted as a single, concatenated 
    bar code.  If the required addenda is not found within the Addenda Timeout period, the EAN-13 bar code is discarded.
    Don’t Require Addenda:  If you have selected Require Addenda, and you want to disable this feature, scan Don’t 
    Require Addenda.  EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda 
    Required.
    Default = Don’t Require Addenda.
    EAN-13 Beginning with 414/419 Addenda Required 
    This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 bar 
    codes that begin with a “414” or “419.”  The following settings can be programmed:
    Require Addenda:  All EAN-13 bar codes that begin with a “414” or “419” must have a 2 digit addenda, a 5 digit addenda, 
    or a combination of these addenda.  The EAN-13 bar code with the addenda is then transmitted as a single, concatenated 
    bar code.  If the required addenda is not found within the Addenda Timeout period, the EAN-13 bar code is discarded.
    Don’t Require Addenda:  If you have selected Require Addenda, and you want to disable this feature, scan Don’t 
    Require Addenda.  EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda 
    Required.
    Default = Don’t Require Addenda.
    * Don’t Require Addenda
    Require 2 Digit Addenda
    Require 5 Digit Addenda
    Require 2 or 5 Digit Addenda
    * Don’t Require Addenda
    Require 2 Digit Addenda 
    						
    							8 - 37
    EAN-13 Beginning with 434/439 Addenda Required 
    This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 bar 
    codes that begin with a “434” or “439.”  The following settings can be programmed:
    Require Addenda:  All EAN-13 bar codes that begin with a “434” or “439” must have a 2 digit addenda, a 5 digit addenda, 
    or a combination of these addenda.  The EAN-13 bar code with the addenda is then transmitted as a single, concatenated 
    bar code.  If the required addenda is not found within the Addenda Timeout period, the EAN-13 bar code is discarded.
    Don’t Require Addenda:  If you have selected Require Addenda, and you want to disable this feature, scan Don’t 
    Require Addenda.  EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda 
    Required.
    Default = Don’t Require Addenda.
    EAN-13 Beginning with 977 Addenda Required
    This setting programs the scanner to require a 2 digit addenda only on EAN-13 bar codes that begin with “977.”  The follow-
    ing settings can be programmed:
    Require 2 Digit Addenda:  All EAN-13 bar codes that begin with “977” must have a 2 digit addendum.  The EAN-13 bar 
    code with the 2 digit addendum is then transmitted as a single, concatenated bar code.  If a 2 digit addendum is not found 
    within the Addenda Timeout period, the EAN-13 bar code is discarded.
    Don’t Require 2 Digit Addenda:  If you have selected Require 2 Digit Addenda, and you want to disable this feature, 
    scan Don’t Require 2 Digit Addenda.  EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/
    JAN-13 Addenda Required.
    Require 5 Digit Addenda
    Require 2 or 5 Digit Addenda
    * Don’t Require Addenda
    Require 2 Digit Addenda
    Require 5 Digit Addenda
    Require 2 or 5 Digit Addenda 
    						
    							8 - 38
    Default = Don’t Require 2 Digit Addenda.
    EAN-13 Beginning with 978 Addenda Required
    These settings program the scanner to require a 5 digit addenda only on EAN-13 bar codes that begin with “978.”  The fol-
    lowing settings can be programmed:
    Require 5 Digit Addenda:  All EAN-13 bar codes that begin with “978” must have a 5 digit addendum.  The EAN-13 bar 
    code with the 5 digit addendum is then transmitted as a single, concatenated bar code.  If a 5 digit addendum is not found 
    within the Addenda Timeout period, the EAN-13 bar code is discarded.
    Don’t Require 5 Digit Addenda:  If you have selected Require 5 Digit Addenda, and you want to disable this feature, 
    scan Don’t Require 5 Digit Addenda.  EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/
    JAN-13 Addenda Required.
    Default = Don’t Require 5 Digit Addenda.
    EAN-13 Beginning with 979 Addenda Required
    These settings program the scanner to require a 5 digit addenda only on EAN-13 bar codes that begin with “979.”  The fol-
    lowing settings can be programmed:
    Require 5 Digit Addenda:  All EAN-13 bar codes that begin with “979” must have a 5 digit addendum.  The EAN-13 bar 
    code with the 5 digit addendum is then transmitted as a single, concatenated bar code.  If a 5 digit addendum is not found 
    within the Addenda Timeout period, the EAN-13 bar code is discarded.
    Don’t Require 5 Digit Addenda:  If you have selected Require 5 Digit Addenda, and you want to disable this feature, 
    scan Don’t Require 5 Digit Addenda.  EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/
    JAN-13 Addenda Required.
    Default = Don’t Require 5 Digit Addenda.
    * Don’t Require 2 Digit Addenda
    Require 2 Digit Addenda
    * Don’t Require 5 Digit Addenda
    Require 5 Digit Addenda
    * Don’t Require 5 Digit Addenda 
    						
    							8 - 39
    Addenda Timeout
    You can set a time during which the scanner looks for an addenda.  If an addenda is not found within this time period, the 
    data can be either transmitted or discarded, based on the setting you are using for EAN/JAN-13 Addenda Required.  Set 
    the length (in milliseconds) for this timeout by scanning the bar code below, then setting the timeout (from 0-65535 millisec-
    onds) by scanning digits from the Programming Chart, then scanning Save.  Default = 100.
    Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.
    EAN/JAN-13 Addenda Separator
    When this feature is On, there is a space between the data from the bar code and the data from the addenda.  When turned 
    Off, there is no space.  Default = Off.
    Note: If you want to enable or disable EAN13 with Extended Coupon Code, refer to UPC-A/EAN-13 with Extended Coupon 
    Code (page 8-28).
    EAN/JAN-13 Redundancy
    If you are encountering errors when reading EAN/JAN-13 bar codes, you may want to adjust the redundancy count.  
    Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of 
    errors.  Note that the higher the redundancy count, the longer it will take to decode the bar code.  To adjust the redundancy, 
    scan the EAN/JAN-13 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the 
    Programming Chart inside the back cover of this manual.  Then scan the Save bar code.  Default = 0.
    ISBN Translate
    When On is scanned, EAN-13 Bookland symbols are translated into their equivalent ISBN number format. Default = Off. 
    Require 5 Digit Addenda
    Addenda Timeout
    On
    * Off
    EAN/JAN-13 Redundancy
    On 
    						
    							8 - 40
    Convert ISBN to 13-Digit
    When translating EAN-13 codes to the ISBN format, you can convert the bar code to a 13 digit format by scanning the 
    Convert to 13-Digit On bar code below.  Default = Convert to 13-Digit Off.
    ISBN Reformat
    In normal use, the first two or three digits of an EAN-13 bar code identify the country of origin.  The country prefixes are 
    978 and 979.  To reformat ISBN codes so the country prefix is dropped out, scan the Reformat On bar code below.  
    Default = Refor mat Off.
    ISSN Translate
    When On is scanned, EAN-13 977 Bookland symbols are translated into their equivalent 8-digit ISSN number format.  For 
    example, 9770123456787 will be transmitted as 01234560.  Default = Off.
    *  Off
    Convert to 13-Digit On
    *Convert to 13-Digit Off
    Reformat On
    *Reformat Off
    On
    * Off 
    						
    							8 - 41
    ISSN Reformat
    When Reformat On is scanned, EAN-13 977 Bookland symbols are translated into their equivalent 8-digit ISSN num-
    ber format, with hyphens added to the output.  For example, 9770123456787 will be transmitted as 0123-456-0.  (You 
    must first scan ISSN On (page 8-40) before scanning Reformat On.)  Default = Reformat Off.
    EAN/JAN-8
    
    EAN/JAN-8 On/Off
    EAN/JAN-8 Check Digit
    This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not.  
    Default = On.
    Reformat On
    * Reformat Off
    *  On
    Off
    *  On
    Off 
    						
    							8 - 42
    EAN/JAN-8 Addenda
    This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data.  Default = Off for both 2 Digit and 5 Digit 
    Addenda.
    EAN/JAN-8 Addenda Required
    When Required is scanned, the scanner will only read EAN/JAN-8 bar codes that have addenda.  Default = Not Required.
    Addenda Timeout
    You can set a time during which the scanner looks for an addenda.  If an addenda is not found within this time period, the 
    data can be either transmitted or discarded, based on the setting you are using for EAN/JAN-8 Addenda Required.  Set the 
    length (in milliseconds) for this timeout by scanning the bar code below, then setting the timeout (from 0-65535 millisec-
    onds) by scanning digits from the Programming Chart, then scanning Save.  Default = 100.
    Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.
    2 Digit Addenda On
    * 2 Digit Addenda Off
    5 Digit Addenda On
    * 5 Digit Addenda Off
    Required
    *  Not Required
    Addenda Timeout 
    						
    All Honeywell manuals Comments (23)