Honeywell 1202g2 Manual
Have a look at the manual Honeywell 1202g2 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
10 - 9 RS232 Handshaking *RTS/CTS Off 232CTS02-25 Flow Control, No Timeout 232CTS12-26 Character-Based Flow Control, No Timeout232CTS72-26 Two-Direction Flow Control 232CTS22-26 Flow Control with Timeout 232CTS32-26 Character-Based Flow Control with Timeout232CTS92-26 *RTS/CTS Off, RTS Inactive 232CTS102-25 RS232 Timeout (Range 1-65535) *1000 ms232DEL####2-26 *XON/XOFF Off 232XON02-26 XON/XOFF On 232XON12-26 *ACK/NAK Off 232ACK02-27 ACK/NAK On 232ACK12-27 Communication Timeout (Range 1-65535) *2000 ms232DLK#####2-27 Communication Timeout Beeper - Off HSTTOA02-27 *Communication Timeout Beeper - On HSTTOA12-27 BEL/CAN Mode On BELCAN12-28 *BEL/CAN Mode Off BELCAN02-28 RS232 Defaults Reset RS232 Defaults 232DFT2-28 NCR Modifiers NCR ACK/NAK *NCR ACK/NAK Off NCRACK02-28 NCR ACK/NAK On NCRACK12-28 Block Check Character *Transmit NCRBCC12-29 Don’t Transmit NCRBCC02-29 NCR Prefix/Suffix NCR Prefix NCRPR2##2-29 NCR Suffix *0D NCRSF2##2-29 Transmit Prefix/Suffix NCRBCP12-29 *Don’t Transmit Prefix/Suffix NCRBCP02-29 NCR NOF (Not-on-File) Error On NCRRAZ12-30 *Off NCRRAZ02-30 Scanner to Bioptic Communication *Packet Mode Off 232PKT02-30 Packet Mode On 232PKT22-30 *ACK/NAK Off 232ACK02-30 ACK/NAK On 232ACK12-30 Communication Timeout (Range 1-65535) *2000 ms232DLK#####2-31 Cordless System Operation (Voyager 1202g) Note: This section applies only to Voyager 1202g cordless systems. It does not apply to corded scanners. Base Power Communication Indicator *On :*:BASRED13-5 Off :*:BASRED03-5 Reset Scanner Reset Scanner RESET_3-6 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 10 Scanning While in Base Cradle Scanning in Cradle Off BT_SIC03-6 *Scanning in Cradle On BT_SIC13-6 Paging Mode *On BEPPGE13-7 Off BEPPGE03-7 Paging Pitch Low (*1000) (min 100Hz) BEPPFQ10003-7 Medium (3250) BEPPFQ32503-7 High (4200) (min 5000Hz) BEPPFQ42003-7 Scanner Address Scanner Address BT_LDA3-7 Base Address Base Address :*:BASLDA3-8 Scanner Modes Charge Only Mode :*:BASLNK03-8 *Charge and Link Mode :*:BASLNK13-8 Locked Link Mode :*:BASCON03-8 *Open Link Mode :*:BASCON13-9 Unlink Scanner BT_RMV3-9 Override Locked Scanner BT_RPL13-9 Out-of-Range Alarm Alarm Sound Type BT_ORW3-9 Scanner Alarm Duration (Range 1 - 3000 sec (*1))BT_ORD3-10 Scanner Power Time-Out Timer Timer Off BT_LPT03-10 200 Seconds BT_LPT2003-10 400 Seconds BT_LPT4003-10 900 Seconds BT_LPT9003-10 3600 Seconds BT_LPT36003-10 7200 Seconds BT_LPT72003-10 Batch Mode Automatic Batch Mode BATENA13-11 *Batch Mode Off BATENA03-11 Inventory Batch Mode BATENA23-11 Batch Mode Beep *Off BATBEP03-11 On BATBEP13-11 Batch Mode Quantity *Off BATQTY03-12 On BATQTY13-12 Quantity Codes 0 BATNUM03-12 1 BATNUM13-12 2 BATNUM23-13 3 BATNUM33-13 4 BATNUM43-13 5 BATNUM53-13 6 BATNUM63-13 7 BATNUM73-13 8 BATNUM83-13 9 BATNUM93-13 Delete Last Code Delete Last Code BATUND3-13 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 11 Record Counter *Record Counter Off BATENT03-14 Record Counter On BATENT13-14 Total Records Total Records BATNRC3-14 Batch Mode Output Order *FIFO BATLIF03-14 LIFO BATLIF13-14 Clear All Codes After Transmission *Don’t Clear All Codes After Transmission BATCLX03-14 Clear All Codes After Transmission BATCLX13-14 Clear All Codes Clear All Codes BATCLR3-15 Transmit Records Automatically *Don’t Transmit Records Automatically BATATX03-15 Transmit Records Automatically BATATX13-15 Transmit Records to Host Transmit Inventory Records BAT_TX3-15 Batch Mode Transmit Delay *Off BATDLY03-15 Short (ms) BATDLY2503-15 Medium (ms) BATDLY5003-16 Long (ms) BATDLY10003-16 Scanner Name Scanner Name BT_NAM3-17 Using the Scanner with Bluetooth DevicesBluetooth Serial Port - PCs/Laptops BT_TRM0;BT_DNG53-17 Bluetooth PIN Code Bluetooth PIN *0000BT_PIN3-17 Auto Reconnect Mode *Auto Reconnect On BT_ACM13-17 Auto Reconnect Off BT_ACM03-18 Maximum Link Attempts Maximum Link Attempts Range 0-255 (*0)BT_MLA###3-18 Reset Reset Base RESET_3-19 Reset Scanner :*:RESET_3-19 Cordless System Operation (Voyager 1202g-BF) Note: This section applies only to Voyager 1202gt-BF cordless systems. It does not apply to corded scanners. Base Power Communication Indicator *On :*:BASRED14-4 Off :*:BASRED04-4 Reset Scanner Reset Scanner RESET_4-4 Scanning While in Base Cradle Scanning in Cradle Off BT_SIC04-5 *Scanning in Cradle On BT_SIC14-5 Paging Mode *On BEPPGE14-5 Off BEPPGE04-5 Paging Pitch Low (*1000) (min 100Hz) BEPPFQ10004-5 Medium (3250) BEPPFQ32504-5 High (4200) (min 5000Hz) BEPPFQ42004-6 Scanner Address Scanner Address BT_LDA4-6 Base Address Base Address :*:BASLDA4-6 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 12 Scanner Modes Charge Only Mode :*:BASLNK04-6 *Charge and Link Mode :*:BASLNK14-6 Locked Link Mode :*:BASCON04-7 *Open Link Mode :*:BASCON14-7 Unlink Scanner BT_RMV4-7 Override Locked Scanner BT_RPL14-7 Out-of-Range Alarm Scanner Alarm Type BT_ORW4-8 Scanner Alarm Duration (Range 1 - 3000 sec (*1))BT_ORD4-8 Auto Reconnect Mode *Auto Reconnect On BT_ACM14-8 Auto Reconnect Off BT_ACM04-8 Maximum Link Attempts Maximum Link Attempts Range 0-255 (*0)BT_MLA###4-9 Reset Reset Base RESET_4-10 Reset Scanner :*:RESET_4-10 Input/Output Selections Power Up Beeper Power Up Beeper Off - Scanner BEPPWR05-1 *Power Up Beeper On - Scanner BEPPWR15-1 Beep on BEL Character Beep on BEL On BELBEP15-1 *Beep on BEL Off BELBEP05-1 Beeper - Good Read Off BEPBEP05-1 *On BEPBEP15-1 Beeper Volume - Good Read Off BEPLVL05-1 Low BEPLVL15-2 Medium BEPLVL25-2 *High BEPLVL35-2 Beeper Pitch - Good Read (Frequency)Low (1600 Hz) BEPFQ116005-2 *Medium (2350 Hz) BEPFQ123505-2 High (4200 Hz) BEPFQ142005-2 Beeper - Transmit Order Before Transmission BEPWHN15-2 After Transmission BEPWHN25-2 Beeper Pitch - Error (Frequency) *Razz (100 Hz) BEPFQ21005-3 Medium (2000 Hz) BEPFQ220005-3 High (4200 Hz) BEPFQ242005-3 Beeper Duration - Good Read *Normal Beep BEPBIP05-3 Short Beep BEPBIP15-3 Number of Beeps - Good Read Range 1 - 9 (*1) BEPRPT#5-3 Number of Beeps - Error Range 1 - 9 (*1) BEPERR#5-4 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 13 LED Settings Red LED Off LEDFN105-4 Green LED Off LEDFN205-4 Red LED On with Good Scan LEDFN115-4 Green LED On with Good Scan LEDFN215-4 *Red LED On with Laser LEDFN125-4 *Red LED On with Laser/Red LED Blinks when Battery is LowLEDFN110265-4 Green LED On with Laser LEDFN225-4 Red LED On when CodeGate Disabled LEDFN145-4 Green LED On when CodeGate Disabled LEDFN245-5 Red LED On when In-Stand LEDFN185-5 Green LED On when In-Stand LEDFN285-5 Red LED On with CTS LEDFN11285-5 Green LED On with CTS LEDFN21285-5 Red LED when Battery is Low LEDFN110245-5 Green LED when Battery is Low LEDFN210245-5 LED Brightness Red Off LEDIN105-5 Green Off LEDIN205-5 Red Low LEDIN115-5 Green Low LEDIN215-6 Red Medium LEDIN125-6 Green Medium LEDIN225-6 *Red High LEDIN135-6 *Green High LEDIN235-6 In-Stand and Out-of-Stand Settings In-Stand Defaults AISDFT5-6 Out-of-Stand Defaults AOSDFT5-6 Presentation Mode Out-of-Stand PAPPM15-7 Presentation Mode with CodeGate Out-of- StandPAPPM25-7 Manual Activation Mode Off In-Stand AISMEN05-7 *Manual Activation Mode On In-Stand AISMEN15-7 Manual Activation Mode Off Out-of-Stand AOSMEN05-7 *Manual Activation Mode On Out-of-Stand AOSMEN15-7 Do Not End Manual Activation After Good Read In-StandAISMGD05-7 *End Manual Activation After Good Read In-StandAISMGD15-8 Do Not End Manual Activation After Good Read Out-of-StandAOSMGD05-8 *End Manual Activation After Good Read Out-of-StandAOSMGD15-8 Laser Timeout - Button Hold In-Stand (Range 1 - 65525) *5000 msAISMPT#####5-8 Laser Timeout - Button Release In-Stand (Range 1 - 65525) *0 msAISMRT#####5-8 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 14 Laser Timeout - Button Hold Out-of-Stand (Range 1 - 65525) *5000 msAOSMPT#####5-8 Laser Timeout - Button Release Out-of- Stand (Range 1 - 65525) *0 msAOSMRT#####5-8 *CodeGate Off In-Stand AISCGD05-9 CodeGate On In-Stand AISCGD15-9 CodeGate Off Out-of-Stand AOSCGD05-9 *CodeGate On Out-of-Stand AOSCGD15-9 *Button Function Off BTNFNC05-9 Button Function On BTNFNC15-9 Object Detection Mode Off In-Stand AISOEN05-9 Object Detection Mode On Out-of-Stand AOSOEN15-10 *Object Detection Mode Off Out-of-Stand AOSOEN05-9 *Object Detection Mode On In-Stand AISOEN15-10 Do Not End Object Detection After Good Read In-StandAISOGD05-10 *End Object Detection After Good Read In-StandAISOGD15-10 Do Not End Object Detection After Good Read Out-of-StandAOSOGD05-10 *End Object Detection After Good Read Out-of-StandAOSOGD15-10 Object Detection Laser Timeout In-Stand (Range 1 - 65525) *5000 msAISODT#####5-11 Object Detection Laser Timeout Out-of- Stand (Range 1 - 65525) *5000 msAOSODT#####5-11 *Object Detection Distance - Short In- StandAISRNG25-11 Object Detection Distance - Long In-Stand AISRNG15-11 Object Detection Distance - Short Out-of- StandAOSRNG25-11 *Object Detection Distance - Long Out-of- StandAOSRNG15-11 Character Activation Mode *Off HSTCEN05-11 On HSTCEN15-12 Activation Character HSTACH##5-12 Do Not End Character Activation After Good ReadHSTCGD05-12 *End Character Activation After Good ReadHSTCGD15-12 Character Activation Laser Timeout (Range 1 - 65525) *5000 msHSTCDT#####5-12 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 15 Character Deactivation Mode *Off HSTDEN05-12 On HSTDEN15-13 Deactivation Character HSTDCH##5-13 Reread Delay Short (500 ms) DLYRRD5005-13 *Medium (750 ms) DLYRRD7505-13 Long (1000 ms) DLYRRD10005-13 Extra Long (2000 ms) DLYRRD20005-13 User-Specified Reread Delay Range 0 - 30,000 ms DLYRRD#####5-13 Output Sequence Editor Enter Sequence SEQBLK5-16 Default Sequence SEQDFT5-16 Sequence Timeout (Range 1 - 65535) *5000 ms SEQDLY#####5-16 Sequence Match Beeper *On SEQBEP15-16 Off SEQBEP05-16 Partial Sequence Transmit Partial Sequence SEQTTS15-16 *Discard Partial Sequence SEQTTS05-17 Require Output Sequence Required SEQ_EN25-17 On/Not Required SEQ_EN15-17 *Off SEQ_EN05-17 No Read On SHWNRD15-17 *Off SHWNRD05-17 Prefix/Suffix Selections Add CR Suffix to All Symbologies VSUFCR6-2 Prefix Add Prefix PREBK2##6-2 Clear One Prefix PRECL26-2 Clear All Prefixes PRECA26-2 Suffix Add Suffix SUFBK2##6-2 Clear One Suffix SUFCL26-2 Clear All Suffixes SUFCA26-2 Transmit Alternate Extended ASCII Characters*Transmit Alternate Extended ASCIi KBDEXT06-3 Transmit Normal Extended ASCIi KBDEXT16-3 Function Code Transmit *Enable RMVFNC06-4 Disable RMVFNC16-4 Communication Check Character *None HSTXRC06-4 LRC Starts on 1st Character HSTXRC16-4 LRC Starts on 2nd Character HSTXRC26-4 CRC HSTXRC36-4 Intercharacter Delay Range 0 - 65535 (5ms increments) DLYCHR##6-5 User Specified Intercharacter DelayDelay Length 0 - 65535 (5ms increments)DLYCRX##6-5 Character to Trigger Delay DLY_XX##6-5 Interfunction Delay Range 0 - 65535 (5ms increments) DLYFNC##6-6 Intermessage Delay Range 0 - 65535 (5ms increments) DLYMSG##6-6 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 16 Data Formatter Selections Data Format Editor *Default Data Format (None) DFMDF37-1 Enter Data Format DFMBK3##7-2 Clear One Data Format DFMCL37-2 Clear All Data Formats DFMCA37-2 Data Formatter Data Formatter Off DFM_EN07-10 *Data Formatter On, Not Required, Keep Prefix/SuffixDFM_EN17-10 Data Format Required, Keep Prefix/SuffixDFM_EN27-11 Data Formatter On, Not Required, Drop Prefix/SuffixDFM_EN37-10 Data Format Required, Drop Prefix/SuffixDFM_EN47-11 Data Format Non-Match Error Tone *Data Format Non-Match Error Tone On DFMDEC07-11 Data Format Non-Match Error Tone Off DFMDEC17-11 Primary/Alternate Data Formats Primary Data Format ALTFNM07-11 Data Format 1 ALTFNM17-11 Data Format 2 ALTFNM27-11 Data Format 3 ALTFNM37-11 Single Scan Data Format Change Single Scan-Primary Data FormatVSAF_07-12 Single Scan-Data Format 1 VSAF_17-12 Single Scan-Data Format 2 VSAF_27-12 Single Scan-Data Format 3 VSAF_37-12 Symbologies All Symbologies All Symbologies Off ALLENA08-1 All Symbologies On ALLENA18-1 Codabar Default All Codabar SettingsCBRDFT8-2 Off CBRENA08-2 *On CBRENA18-2 Codabar Start/Stop Char.*Don’t Transmit CBRSSX08-2 Transmit CBRSSX18-2 Codabar Check Char.*No Check Char. CBRCK208-2 Validate Modulo 16, But Don’t Transmit CBRCK218-2 Validate Modulo 16, and Transmit CBRCK228-3 Validate Modulo 7 CD, But Don’t Transmit CBRCK238-3 Validate Modulo 7 CD, and Transmit CBRCK248-3 Validate CLSI, But Don’t Transmit CBRCK258-3 Validate CLSI, and Transmit CBRCK268-3 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 17 Codabar Concatenation *Off CBRCCT08-3 On CBRCCT18-3 Require CBRCCT28-3 Concatenation Timeout DLYCCT8-4 Codabar Redundancy Range (0 - 10) *0 CBRVOT##8-4 Codabar Message Length Minimum (1 - 80) *3 CBRMIN##8-4 Maximum (1 - 80) *80 CBRMAX##8-4 Code 39 Default All Code 39 SettingsC39DFT8-5 Off C39ENA08-5 *On C39ENA18-5 Code 39 Start/Stop Char.*Don’t Transmit C39SSX08-5 Transmit C39SSX18-5 Code 39 Check Char.*No Check Char. C39CK208-5 Validate, But Don’t TransmitC39CK218-5 Validate, and TransmitC39CK228-5 Code 39 Redundancy Range (0 - 10) *0 C39VOT##8-6 Code 39 Message Length Minimum (1 - 80) *3 C39MIN##8-6 Maximum (1 - 80) *80 C39MAX##8-6 Code 32 Pharmaceutical (PARAF) *Off C39B3208-6 On C39B3218-6 Code 39 Full ASCII *Off C39ASC08-7 On C39ASC18-7 Interleaved 2 of 5 Default All Interleaved 2 of 5 SettingsI25DFT8-8 Off I25ENA08-8 *On I25ENA18-8 NULL Characters *Off I25NUL08-8 On I25NUL18-8 Interleaved 2 of 5 Check Digit*No Check Char. I25CK208-8 Validate, But Don’t TransmitI25CK218-8 Validate, and Transmit I25CK228-9 Interleaved 2 of 5 Redundancy Range (0 - 10) *0 I25VOT##8-9 Interleaved 2 of 5 Message Length Minimum (1 - 80) *6 I25MIN##8-9 Maximum (1 - 80) *80 I25MAX##8-9 NEC 2 of 5 Default All NEC 2 of 5 SettingsN25DFT8-9 *Off N25ENA08-9 On N25ENA18-9 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 18 NEC 2 of 5 Check Digit*No Check Char. N25CK208-10 Validate, But Don’t TransmitN25CK218-10 Validate, and Transmit N25CK228-10 NEC 2 of 5 Redundancy Range (0 - 10) *0 N25VOT##8-10 NEC 2 of 5 Message Length Minimum (1 - 80) *3 N25MIN##8-10 Maximum (1 - 80) *80 N25MAX##8-10 Code 93 Default All Code 93 SettingsC93DFT8-11 Off C93ENA08-11 *On C93ENA18-12 Code 93 Redundancy Range (0 - 10) *0 C93VOT##8-11 Code 93 Message Length Minimum (1 - 80) *3 C93MIN##8-11 Maximum (1 - 80) *80 C93MAX##8-11 Straight 2 of 5 Industrial Default All Straight 2 of 5 Industrial SettingsR25DFT8-12 *Off R25ENA08-12 On R25ENA18-12 Straight 2 of 5 Industrial Redundancy Range (0 - 10) *0 R25VOT##8-12 Straight 2 of 5 Industrial Message LengthMinimum (1 - 80) *3 R25MIN##8-12 Maximum (1 - 80) *80 R25MAX##8-12 Straight 2 of 5 IATA Default All Straight 2 of 5 IATA SettingsA25DFT8-13 Straight 2 of 5 IATA *Off A25ENA08-13 On A25ENA18-13 Straight 2 of 5 IATA Redundancy Range (0 - 10) *0 A25VOT##8-13 Straight 2 of 5 IATA Message Length Minimum (1 - 80) *13 A25MIN##8-13 Maximum (1 - 80) *15 A25MAX##8-13 Matrix 2 of 5 Default All Matrix 2 of 5 SettingsX25DFT8-14 *Off X25ENA08-14 On X25ENA18-14 Matrix 2 of 5 Redundancy Range (0 - 10) *0 X25VOT##8-14 Matrix 2 of 5 Message Length Minimum (1 - 80) *3 X25MIN##8-15 Maximum (1 - 80) *80 X25MAX##8-15 Matrix 2 of 5 Check Char.*No Check Char. X25CK208-14 Validate, But Don’t TransmitX25CK218-14 Validate and Transmit X25CK228-14 Code 11 Default All Code 11 SettingsC11DFT8-15 *Off C11ENA08-15 On C11ENA18-15 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage