Page 181

10 - 9
RS232 Handshaking *RTS/CTS Off 232CTS02-25
Flow Control, No Timeout 232CTS12-26
Character-Based Flow Control, No 
Timeout232CTS72-26
Two-Direction Flow Control 232CTS22-26
 Flow Control with Timeout 232CTS32-26
Character-Based Flow Control with 
Timeout232CTS92-26
*RTS/CTS Off, RTS Inactive 232CTS102-25
RS232 Timeout (Range 1-65535) *1000 
ms232DEL####2-26
*XON/XOFF Off 232XON02-26
XON/XOFF On 232XON12-26
*ACK/NAK Off 232ACK02-27
ACK/NAK On 232ACK12-27
Communication Timeout
(Range 1-65535) *2000...

Page 182

10 - 10
Scanning While in Base Cradle Scanning in Cradle Off BT_SIC03-6
*Scanning in Cradle On BT_SIC13-6
Paging Mode *On BEPPGE13-7
Off BEPPGE03-7
Paging Pitch Low (*1000) (min 100Hz) BEPPFQ10003-7
Medium (3250) BEPPFQ32503-7
High (4200) (min 5000Hz) BEPPFQ42003-7
Scanner Address Scanner Address BT_LDA3-7
Base Address Base Address :*:BASLDA3-8
Scanner Modes Charge Only Mode :*:BASLNK03-8
*Charge and Link Mode :*:BASLNK13-8
Locked Link Mode :*:BASCON03-8
*Open Link Mode :*:BASCON13-9
Unlink Scanner...

Page 183

10 - 11
Record Counter *Record Counter Off BATENT03-14
Record Counter On BATENT13-14
Total Records Total Records BATNRC3-14
Batch Mode Output Order *FIFO BATLIF03-14
LIFO BATLIF13-14
Clear All Codes After Transmission *Don’t Clear All Codes After Transmission BATCLX03-14
Clear All Codes After Transmission BATCLX13-14
Clear All Codes Clear All Codes BATCLR3-15
Transmit Records Automatically *Don’t Transmit Records Automatically BATATX03-15
Transmit Records Automatically BATATX13-15
Transmit Records to...

Page 184

10 - 12
Scanner Modes Charge Only Mode :*:BASLNK04-6
*Charge and Link Mode :*:BASLNK14-6
Locked Link Mode :*:BASCON04-7
*Open Link Mode :*:BASCON14-7
Unlink Scanner BT_RMV4-7
Override Locked Scanner BT_RPL14-7
Out-of-Range Alarm Scanner Alarm Type BT_ORW4-8
Scanner Alarm Duration (Range 1 - 3000 
sec (*1))BT_ORD4-8
Auto Reconnect Mode *Auto Reconnect On BT_ACM14-8
Auto Reconnect Off BT_ACM04-8
Maximum Link Attempts Maximum Link Attempts 
Range 0-255 (*0)BT_MLA###4-9
Reset Reset Base RESET_4-10
Reset...

Page 185

10 - 13
LED Settings Red LED Off LEDFN105-4
Green LED Off LEDFN205-4
Red LED On with Good Scan LEDFN115-4
Green LED On with Good Scan LEDFN215-4
*Red LED On with Laser LEDFN125-4
*Red LED On with Laser/Red LED Blinks 
when Battery is LowLEDFN110265-4
Green LED On with Laser LEDFN225-4
Red LED On when CodeGate Disabled LEDFN145-4
Green LED On when CodeGate Disabled LEDFN245-5
Red LED On when In-Stand LEDFN185-5
Green LED On when In-Stand LEDFN285-5
Red LED On with CTS LEDFN11285-5
Green LED On with CTS...

Page 186

10 - 14
Laser Timeout - Button Hold Out-of-Stand
(Range 1 - 65525) *5000 msAOSMPT#####5-8
Laser Timeout - Button Release Out-of-
Stand
(Range 1 - 65525) *0 msAOSMRT#####5-8
*CodeGate Off In-Stand AISCGD05-9
CodeGate On In-Stand AISCGD15-9
CodeGate Off Out-of-Stand AOSCGD05-9
*CodeGate On Out-of-Stand AOSCGD15-9
*Button Function Off BTNFNC05-9
Button Function On BTNFNC15-9
Object Detection Mode Off In-Stand AISOEN05-9
Object Detection Mode On Out-of-Stand AOSOEN15-10
*Object Detection Mode Off...

Page 187

10 - 15
Character Deactivation Mode *Off HSTDEN05-12
On HSTDEN15-13
Deactivation Character HSTDCH##5-13
Reread Delay Short (500 ms) DLYRRD5005-13
*Medium (750 ms) DLYRRD7505-13
Long (1000 ms) DLYRRD10005-13
Extra Long (2000 ms) DLYRRD20005-13
User-Specified Reread Delay Range 0 - 30,000 ms DLYRRD#####5-13
Output Sequence Editor Enter Sequence SEQBLK5-16
Default Sequence SEQDFT5-16
Sequence Timeout (Range 1 - 65535) *5000 ms SEQDLY#####5-16
Sequence Match Beeper *On SEQBEP15-16
Off SEQBEP05-16
Partial...

Page 188

10 - 16
Data Formatter Selections
Data Format Editor *Default Data Format (None) DFMDF37-1
Enter Data Format DFMBK3##7-2
Clear One Data Format DFMCL37-2
Clear All Data Formats DFMCA37-2
Data Formatter Data Formatter Off DFM_EN07-10
*Data Formatter On,
Not Required, 
Keep Prefix/SuffixDFM_EN17-10
Data Format Required,
Keep Prefix/SuffixDFM_EN27-11
Data Formatter On,
Not Required, 
Drop Prefix/SuffixDFM_EN37-10
Data Format Required,
Drop Prefix/SuffixDFM_EN47-11
Data Format Non-Match Error Tone *Data...

Page 189

10 - 17
Codabar Concatenation *Off CBRCCT08-3
On CBRCCT18-3
Require CBRCCT28-3
Concatenation Timeout DLYCCT8-4
Codabar Redundancy Range (0 - 10) *0 CBRVOT##8-4
Codabar Message Length Minimum (1 - 80)  *3 CBRMIN##8-4
Maximum (1 - 80)  *80 CBRMAX##8-4
Code 39 Default All Code 39 
SettingsC39DFT8-5
Off C39ENA08-5
*On C39ENA18-5
Code 39 Start/Stop Char.*Don’t Transmit C39SSX08-5
Transmit C39SSX18-5
Code 39 Check Char.*No Check Char. C39CK208-5
Validate, But Don’t 
TransmitC39CK218-5
Validate, 
and...

Page 190

10 - 18
NEC 2 of 5 Check Digit*No Check Char. N25CK208-10
Validate, But Don’t 
TransmitN25CK218-10
Validate, and Transmit N25CK228-10
NEC 2 of 5 Redundancy Range (0 - 10) *0 N25VOT##8-10
NEC 2 of 5 Message Length Minimum (1 - 80)  *3 N25MIN##8-10
Maximum (1 - 80)  *80 N25MAX##8-10
Code 93 Default All Code 93 
SettingsC93DFT8-11
Off C93ENA08-11
*On C93ENA18-12
Code 93 Redundancy Range (0 - 10) *0 C93VOT##8-11
Code 93 Message Length Minimum (1 - 80)  *3 C93MIN##8-11
Maximum (1 - 80)  *80 C93MAX##8-11...