GTE Omni Si Database Technical Practices Manual
Here you can view all the pages of manual GTE Omni Si Database Technical Practices Manual. The GTE manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 355
TL-130400-1001Record Code AQ:17.4 Record Code AQ, Figure 17.4, provides a list of parameters Data Systemapplied to the remote end of a data call. These parameters Asynchronous Porttemporarily override the pre-existing parameters of the remote Set/Read Listend of a data call while a data call is connected to/from the port specified on this record code. This allows the port specified in this record code to control the configuration of its call partner on both incoming and outgoing data calls. The remote...
Page 356
TL-130400-1001 Table 17.4 Entry Fields for Record Code AQCOL.COL.VALID NO. NAMEENTRIESCOMMENTS 12PEC0 = PEC number This field determines the location of the port. .~.What PEC is this card located in? 13.r GroupA-D = group Which group (A, B, C, or D) within the PEC is numberthis card? 14-15Card Slot00-l 0 = slotnumberWhich card slot within the group is this card? 16Circuit NumberO-7 = assignedWhich circuit on the card is being used? circuit number 17-19Escape fromO-l 27Data TransferAssign the ASCII...
Page 357
TL-130400-1001Table 17.4Entry Fields for Record Code AQ (Continued)COMMENTS device to begin transmission of a packet. 0 = user cannot initate data forwarding 1 = alphanumericcharacters (A-Z,a-z,O-128 = number4 = characters ESC,BEL,ENQ, ACK 8 = characters 16 = characters 32 = characters 64 = a character inserted by the user in text column 0 or 1, which is not any of the characters listed in O-32 above Indicate the allowed intervals between the user input characters. l-255 = number-This field specifies the...
Page 358
TL-130400-1001 Table 17.4 Entry Fields for Record Code AQ (Continued)COL.COL.VALID NO.NAMEENTRIESCOMMENTS 27Ancillary Device0 = disables flow-The PAD sends a control-S, signaling the (cont’d) Flow Control controldevice to stop transmission to the PAD. 1 = enables flow Should the device continue to transmit and%. controloverrun the buffer, data will be lost. When the PAD becomes unblocked, it transmits a control-Q. Transmission of this character continues until the device starts sending data. . .The PAD...
Page 359
TL-130400-1001CQL.NO. Table 17.4Entry Fields for Record Code AQ (Continued) COL.VALID NAMEENTRIESCOMMENTS 32-34Line Width 0 = functionAssign the the number of output characters to performedbe printed per line at the user device. .=.automatically-This parameter sets the default value of line l-255 = number . . .folding. This determines the number of of characters percharacters to transmit before an automatic linecarriage return/line feed is sent. This causes long lines to fold or wrap to the next line....
Page 360
TL-130400-1001Table 17.4Entry Fields for Record Code AQ (Continued)COMMENTS 5= combination of (1) and (4) 6= insert line feed after each carriage return sent from the user terminal as data, plus to the user terminal as an echo 7= combination of (1) and (6) -This field will usually be set to 0 or 1. If the user’s terminal is double spacing lines, this field should be changed to 0. If the user’s terminal is overprintinglines, this field should -This parameter sets thedefault value ofline feed padding. It...