Home > GTE > Communications System > GTE Omni Si Database Technical Practices Manual

GTE Omni Si Database Technical Practices Manual

Here you can view all the pages of manual GTE Omni Si Database Technical Practices Manual. The GTE manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 341

TL-130400-1001Table 17.3AEntry Fields for Record Code AP (Continued)COMMENTS
uggested value =8 = escape from the data transfer mode
1 for terminals_21 = send an interrupt plus an indication of a
break message to PAD and discard output to
O-31= numberofIndicate how many padding characters are to
be inserted after a carriage return.
-Printing devices need sufficient time for the
suggested
value =mechanism to perform the carriage return.
7 for terminals-This parameter determines the number of
null...

Page 342

TL-130400-1001COL.NO.
Table 17.3AEntry Fields for Record Code AP (Continued)
COL.VALID
NAMEENTRIESCOMMENTS
36-37Transmission 0
Speedidentify the transmission rate at which data is
2
sent.
3-This is a read-only parameter.
.=.120= 110 bps(uses 2 stop bits)
.
132 = 300 bps(uses 1 stop bit)
143= 1.2 kbps(uses 1 stop bit)
or12 = 2.4 kbps(uses 1 stop bit)
1513 = 4.8 kbps(uses 1 stop bit)_14 = 9.6 kbps(uses 1 stop bit)
15= 19.2 kbps(uses 1 stop bit)
This is X.3 parameter 11.
38Flow Control of0 = PAD flowThis...

Page 343

TL-130400-1001
Table 17.3AEntry Fields for Record Code AP (Continued)COMMENTS
suggested value =perform the line feed.
2 for terminals-This parameter determines the default value
of line feed padding.
-This is the number of null characters after a
line feed is sent to a device that the system
will pause before sending additional data.
-The carriage return padding field is normally
assigned. If terminals lose information at the
beginningof each line, the value in this field
during the data 
Vanspreviously...

Page 344

TL-130400-1001
select another character.O-127= ASCII character to be used for line
O-l 27 = characterIdentify the character to be used in editing
suggested value =which willdisplay the current contents of the
18 (Control R) for
-See theprevious ASCIIcharacterset to
select another character.
ASCII character to be used for line
r the appropriate value (O-127) from
Table 
17.3B.-This option selects local (not CCITT
standardized) parameter number 1.
-Asynchronous host = 127
-Each APM user can specify the...

Page 345

TL-130400-1001
Table 17.314Entry Fields for Record Code AP (Continued)
COMMENTS
transparently throughnetwork(transmit parity
received through network)
1 = check local parity and send space parity
through network (ignore parity received
through network)
-This parameter determines the default value
of eighth bit transparency.
-This function specifies that the PAD should
or should not check parity.
-This field is normally set to N for
asynchronous devices.
-This field selects local (not CCITT...

Page 346

TL-130400-1001COL.COL.VALID
NO.NAMEENTRIESCOMMENTS
61-63Break Signal002-006 = numberAssign the length of the break signal to the
Timing
of incrementsasynchronous device.
%suggested value =-The selection must be made in increments
. . . .5 (250 ms) forof 50 ms, so a selection of 2 = 100 ms.
terminals
5 (250 ms) for host
64-66
Command
O-255 = numberIf this timer is enabled, it drops the
Inactivity Timerof incrementsconnection when no user commands are sent
suggested value =within the time period...

Page 347

TL-130400-1001Table 17.3AEntry Fields for Record Code AP (Continued)
COL.COL.VALID
NO.NAMEENTRIESCOMMENTS
70
. . .Data Set SignalY = timer enabledThis field determines whether or not this timer
Wait-Down
N = timer disabledis enabled or disabled.
Timersuggested value =-The timer controls the delay between the.”Y for terminalstime when the user disconnects (goes on-
N for hosthook) and the time when the connection is
actually dropped.
-If Y is selected (enable), mark Record
Code Cl, columns 46-48, with the...

Page 348


				            

Page 349


				            

Page 350


				            
Start reading GTE Omni Si Database Technical Practices Manual

Related Manuals for GTE Omni Si Database Technical Practices Manual