Page 361
TL-130400-I 001Table 17.4Entry Fields for Record Code AQ (Continued) COL.COL.VALID NO.NAMEENTRIESCOMMENTS40 . . . . Local Parity0Indicate whether or not a local parity check is Check Ot-performed. Y-1 = number-This parameter sets the default value of eighth bit transparency. This determines if the PAD checks the parity bit. If enabled, the PAD will check parity. Normally, this field is set at 0 for asynchronous devices._ _0 = no local parity check and send transparently through the network (transmit...
Page 362
TL-130400-1001Record Code XP:17.5 Record Code XP, Figure 17.5, defines the parameters Data Systemrequired to describe the X.25 port attributes. An XP record is x.25 Port required for every SPM (Synchronous Packet Manager) on the system. One is also required for the ADMP. The parameters below specify situations where the SPM ports must be configured differently than the ADMP ports. If this is not specified, configure the ADMP ports the same as SPM ports. NOTE: For an ADMP (defined as PX25 in Record Code...
Page 363
I12COL. COL. NO. NO. 12 13 13 . . . 14-15 16. 17-18 19 20 SW 5210TL-130400-1001 Table 17.5Entry Fields for Record Code XP COL.NAME PEC Group s-.”Card Slot Circuit Number X.25 Speed Port May Call Itself Allocate LCNsin Ascending OrderVALID ENTRIES 0 = PEC number A-D = groupnumber 00-l 0 = slotnumber O-7 = assignedcircuit number 01=1,200 baud 02=2,400 baud 03=4,800 baud 04=9,600 baud 05=19.2 kbps 06=48 kbps 07=56 kbps 08=64 kbps Y = port may call itself N = port may not call itself ADMP = N SPM=Y...
Page 364
TL-130400-1001 Table 17.5Entry Fields for Record Code XP (Continued)COMMENTS synchronous device. -This field must be marked N because This fieldmust bebisynchronization is not supported in this SVR. -This field specifies the frame sync character for the bisynchronous protocol only. If this = 1, the character will be hex 32, which is the EBCDIC equivalent of the sync character. Otherwisethe sync character will be hex 16, e ASCII equivalent of the sync N = not HDLCermines w device attached to this port...
Page 365
-TL-130400-1001 COL.NO. Table 17.5Entry Fields for Record Code XP (Continued) COL.VALID NAME ENTRIESCOMMENTS 26 . . .External Clocking _.Y = externallyIndicate whether or not this device is clocked clockedfrom an external source. N = not externally-Enter N for all devices except NIC which clockedmust be marked Y. -If this field= Y, the SPM will be clocked via pins 15 and 17 of the RS-232 or V35 connector connected to the X.25 SPM. If N, . .the SPM provides clocking to the line (must not be a modem). -If...
Page 366
TL-130400-1001Table 17.5Entry Fields for Record Code XP (Continued) COL.COL.VALID NO. NAMEENTRIESCOMMENTS 51-53Frame Size000-007This field determines the frame size or number suggested value = of bits per packet. w-005000= 16 001 = 32 002 = 64 003= 128 004 = 256_ 005= 512 006 = 1,024 007 = 2,048 54-56Frame Window001-l 27 = windowIdentify the maximum number of Sizesize unacknowledged frames that can be sent or suggestedreceived at one time. This can range from 1 value = 007to 7 (module 8) if extended...
Page 367
TL-130400-1001Table 17.5Entry Fields for Record Code XP (Continued) COL.COL.VALID NO.NAMEENTRIESCOMMENTS 66-68Call002-063 = timerThis field determines the timing factor for Retransmission range retransmitting calls. Timer Enter 018 for all (1 &Second)-This value is specified in increments of 10 devices.seconds. . . . . 69-71Reset002-063 = timerThis field determines the timing factor for Retransmission rangesending resets. TimerEnter 006 for all (1 O-Second) ‘- devices.-This value is specified in...
Page 368
TL-130400-1001Record Code Pl:17.6 Record Code Pl , Figure 17.6, defines the parameters Data Systemrequired by the data system ADMP processor. The PI Record Global Parameter -Code will contain only one record. Part 1 r---------r-------r-----r---r-T---------------------------------------------~I1,III III III I1 I -II II I,F S’-NIR C,Ai$ &YE QDI : 1 1 1 II I II; AIPIIICI .oII SIIII :II; DII II 1 III 1 III 1 III ’ III 1 III ’ II II- I I...
Page 369
TL-130400-1001COL. NO. Table 17.6Entry Fields for Record Code Pl COL.VALID NAMEENTRIESCOMMENTS 12 . . .ADM P AccessY=yesThis field determines whether or not the ADMP from DataN=no user interface can be accessed from ports Network andother than the ADMP maintenance terminal.RSr232-This field allows or disallows access to the ADMP from the data network. 13-15Universal000-255 = number This field determines how often the ADMP Controller Board of seconds forshould poll the UCB to check its operation. Polling...
Page 370
TL-130400-1001COL.NO. Table 17.6Entry Fields for Record Code Pl (Continued) COL.VALID NAMEENTRIESCOMMENTS 20Stop Account Y = stop recordingThis field determines the action that is taken Recording on N = overwrite oldwhen the file is full. File Full __-accounting Y = recording is stopped when the event file is records full.- ..N = overwrite the oldest event record -This currently impacts systems where event reports are saved until a device calls the ADMP. -Up to 4,000 event reports can be saved...