Page 361

TL-130400-I 001Table 17.4Entry Fields for Record Code AQ (Continued)
COL.COL.VALID
NO.NAMEENTRIESCOMMENTS40
. . . .
Local Parity0Indicate whether or not a local parity check is
Check
Ot-performed.
Y-1 = number-This parameter sets the default value of
eighth bit transparency. This determines if the
PAD checks the parity bit. If enabled, the PAD
will check parity. Normally, this field is set at 0
for asynchronous devices._
_0 = no local parity check and send
transparently through the network (transmit...

Page 362

TL-130400-1001Record Code XP:17.5 Record Code XP, Figure 17.5, defines the parameters
Data Systemrequired to describe the X.25 port attributes. An XP record is
x.25 Port
required for every SPM (Synchronous Packet Manager) on the
system. One is also required for the ADMP. The parameters
below specify situations where the SPM ports must be configured
differently than the ADMP ports. If this is not specified, configure
the ADMP ports the same as SPM ports.
NOTE: For an ADMP (defined as PX25 in Record Code...

Page 363

I12COL. COL.
NO. NO.
12
13
13
. . .
14-15
16.
17-18
19
20
SW 5210TL-130400-1001
Table 17.5Entry Fields for Record Code XP
COL.NAME
PEC
Group
s-.”Card Slot
Circuit Number
X.25 Speed
Port May Call
Itself
Allocate 
LCNsin Ascending
OrderVALID
ENTRIES
0 = PEC number
A-D = groupnumber
00-l 0 = slotnumber
O-7 = assignedcircuit number
01=1,200 baud
02=2,400 baud
03=4,800 baud
04=9,600 baud
05=19.2 kbps
06=48 kbps
07=56 kbps
08=64 kbps
Y = port may call
itself
N = port may not
call itself
ADMP = N
SPM=Y...

Page 364

TL-130400-1001
Table 17.5Entry Fields for Record Code XP (Continued)COMMENTS
synchronous device.
-This field must be marked N because
This fieldmust bebisynchronization is not supported in this SVR.
-This field specifies the frame sync character
for the bisynchronous protocol only. If this
= 1, the character will be hex 32, which is
the EBCDIC equivalent of the sync character.
Otherwisethe sync character will be hex 16,
e ASCII equivalent of the sync
N = not HDLCermines w
device attached to this port...

Page 365

-TL-130400-1001
COL.NO.
Table 17.5Entry Fields for Record Code XP (Continued)
COL.VALID
NAME
ENTRIESCOMMENTS
26
. . .External
Clocking
_.Y = externallyIndicate whether or not this device is clocked
clockedfrom an external source.
N = not externally-Enter N for all devices except NIC which
clockedmust be marked Y.
-If this field= Y, the SPM will be clocked via
pins 15 and 17 of the RS-232 or V35
connector connected to the X.25 SPM. If N,
. .the SPM provides clocking to the line (must
not be a modem).
-If...

Page 366

TL-130400-1001Table 17.5Entry Fields for Record Code XP (Continued)
COL.COL.VALID
NO.
NAMEENTRIESCOMMENTS
51-53Frame Size000-007This field determines the frame size or number
suggested value =
of bits per packet.
w-005000= 16
001 = 32
002 = 64
003= 128
004 = 256_
005= 512
006 = 1,024
007 = 2,048
54-56Frame Window001-l 27 = windowIdentify the maximum number of
Sizesize
unacknowledged frames that can be sent or
suggestedreceived at one time. This can range from 1
value = 007to 7 (module 8) if extended...

Page 367

TL-130400-1001Table 17.5Entry Fields for Record Code XP (Continued)
COL.COL.VALID
NO.NAMEENTRIESCOMMENTS
66-68Call002-063 = timerThis field determines the timing factor for
Retransmission range
retransmitting calls.
Timer
Enter 018 for all
(1 &Second)-This value is specified in increments of 10
devices.seconds.
. . . .
69-71Reset002-063 = timerThis field determines the timing factor for
Retransmission rangesending resets.
TimerEnter 006 for all
(1 O-Second) 
‘- devices.-This value is specified in...

Page 368

TL-130400-1001Record Code Pl:17.6 Record Code Pl , Figure 17.6, defines the parameters
Data Systemrequired by the data system ADMP processor. The PI Record
Global Parameter -Code will contain only one record.
Part 1
r---------r-------r-----r---r-T---------------------------------------------~I1,III
III
III
I1
I 
-II
II I,F S’-NIR C,Ai$ &YE QDI :
1 1 1
II
I
II; AIPIIICI .oII SIIII :II; DII
II 1 III 1 III 1 III ’ III 1 III ’ II
II-
I I...

Page 369

TL-130400-1001COL.
NO.
Table 17.6Entry Fields for Record Code Pl
COL.VALID
NAMEENTRIESCOMMENTS
12
. . .ADM P AccessY=yesThis field determines whether or not the ADMP
from DataN=no
user interface can be accessed from ports
Network andother than the ADMP maintenance terminal.RSr232-This field allows or disallows access to the
ADMP from the data network.
13-15Universal000-255 = number
This field determines how often the ADMP
Controller Board of seconds forshould poll the UCB to check its operation.
Polling...

Page 370

TL-130400-1001COL.NO.
Table 17.6Entry Fields for Record Code Pl (Continued)
COL.VALID
NAMEENTRIESCOMMENTS
20Stop Account
Y = stop recordingThis field determines the action that is taken
Recording on
N = overwrite oldwhen the file is full.
File Full 
__-accounting
Y = recording is stopped when the event file is
records
full.- ..N = overwrite the oldest event record
-This currently impacts systems where event
reports are saved until a device calls the
ADMP.
-Up to 4,000 event reports can be saved...