Page 191
TL-130100-1001OPERATIONRESULT(e) Trunk andstation numbers cleared from variable display.(f) Class-of-service digits cleared if present. (g) TOD displayed. 4.17Extending Information Call on Outside Number, WATS Line, or FX Line 4.17.1 Attendant Completes Call STEPOPERATIONRESULT 1Station user requests outside number. 2Dial appropriate access code.(a) EXCL SRCE LED on. (b) Fixed display cleared.(c) Second dial and tick tone heard. (d) Dialed digits appear on fixed display. 3Dial outside number.(a) Ringback...
Page 192
TL-130100-10014.17.2 Station User Completes Call STEPOPERATIONRESULT 1Station user requests assistance to reach outside number.(a) Acknowledge request.(b) inform station user that outside number can be dialed from station upon hearing outside dial tone. NOTES: 1.If the attendant extended the station to the trunk, the station’s class of service is used for toll restriction. 2.If the attendant wants to bypass toll restriction, the entire number must be dialed before extending the trunk to the station....
Page 193
TL-130100-1001STEPOPERATIONRESULT 4When tie-line party answers, announce call. NOTE:Disconnect when ringback tone heard. 5Depress lighted EXCL SRCE LED pushbutton. .EXCL SRCE LED off. 6Depress POS RLSE pushbutton to(a) Fixed display cleared. release from call.(b) LOOP and POS RLSE LEDs off. (c) TOD displayed. (d) Station and the Tie Line party are talking. 4.19 Attendant Conference 4.19.1Establish Conference Call for Inside Party STEPOPERATIONRESULT1 2 3 4 NOTE: 5 6 5210Obtain all names and station...
Page 194
TL-130100-1001STEPOPERATIONRESULT 7 8 9NOTE: 10 11Depress CONF pushbutton.(a) CONF LED flashes. (b) EXCL SRCE LED on. (c) Beak-in tone heard by conferee. (d) Attendant placed in conference. Depress EXCL SRCE pushbutton.(a) The EXCL SRCE LED off. (b) Called party placed in conference. Depress flashing CONF LED(a) CONF LED on. pushbutton.(b) Attendant removed from conference. Trunks that do not guarantee disconnect supervision remain in conference bridge until last station hangs up regardless of when trunk...
Page 195
TL-130100-10014.20.3Placing Call in Page Queue STEPOPERATIONRESULTIncoming trunk call placed to Attendant Console. Depress flashing LED LOOP pushbutton. Depress PAGE Q pushbutton. Depress POS RLSE pushbutton. Depress and hold the PAGE push- button and page the desired party. Release PAGE pushbutton. Dial page queue access code from any station. Dial attendant from any station as an alternative to Step 7. Depress flashing LOOP LED pushbutton.(a) Ringing heard. (b) LOOP LED (l-4) flashes at 120 IPM. (a)...
Page 196
-- TL-130100-1001STEP OPERATlONRESULT 10Depress PAGE Q pushbutton.(a) The PAGE Q LED off. (b) Three-way conversation established ,between attendant, trunk, and station. 11Depress POS RLSE pushbutton.(a) The LOOP LED off. (b) POS RLSE LED off. (c) EXCL SRCE or EXCL DEST LED off if (d) Fked display cleared. (e) Trunk and station identification cleared from variable display. (f) Class-of-service digits cleared if present. (g) TOD displayed. (h) Trunk and station are connected. 42Dial attendant from any...
Page 197
TL-130100-1001 4.20.5If Paged Party Calls Attendant STEPOPERATIONRESULT 1 2 3 NOTE:Depress flashing LED LOOP pushbutton.(a) LOOP LED on. (b) START/STOP LED on. (c) POS RLSE LED on. (d) Station number displayed in trunk-and-station-number display. (e) The class-of-service digits displayed in class-of-service display. (f) “INFORMATION” displayed in type-of-call display. After answering paged party, depress(a) PAGE Q LED off. PAGE Q pushbutton. (b) Three-way call established. To release call, depress POS...
Page 198
.’.T I. TL-I 3OlOO-1001 STEPOPERATIONRESULT 3Depress PAGE Q pushbutton. 4 5Depress START/STOP pushbutton. Incoming trunk call placed to an attendant that does not have PAGE Q equipped. 6Depress flashing LED LOOP pushbutton. 7Depress PAGE Q pushbutton.(a) PAGE Q access denied. (b) Appropriate message displayed indicating failure. START/STOP LED off. (a) Ringing heard. (b) LOOP LED (l-4) flashes at 120 IPM. (a) LOOP LED on. (b) “LOCAL” appears in fixed display field. (c) Trunk number appears in variable...
Page 199
TL-130100-10014.19.3 Station on Outside Party Requests Inclusion in Existing Conference STEPOPERATIONRESULT 1If calling party requests entry in existing conference, depress the lighted CONF LED pushbutton. 2Depress EXCL. SRCE LED pushbutton if conferees are allowed entry. 3Depress flashing CONF LED pushbutton. 4 Depress POS RLSE pushbutton to release loop. 5Depress flashing CONF LED pushbutton if conferees are denied entry. 6Depress EXCL SRCE pushbutton. 7Inform calling party of reason for entry denial....
Page 200
TL-I 30100-l 001 OPERATIONRESULTDial conference bridge 2 access code. (a) Fixed display cleared.(b) If conference bridge 2 is idle, CONF LED (c) i:onference bridge 2 is busy, CONF LED remains on. (d) Dialed digits appear on fixed display. 4.20 4.20.1 Paging Universal Paging OPERATION RESULT 1Depress and hold PAGE pushbutton for duration of page or message.(a) PAGE LED on. (b) Message or page heard over loudspeakers. 2Release PAGE pushbutton.(a) PAGE LED off. (b) Attendant disconnected from paging...