Programming Station 
WORK ORDER #2.2 
:OMPANY NAME: NU SYSTEM CO. 
OCATION: RESTON, VIRGINIA 
,RIGlNATOR: TELECOMMUNICATIONS MANAGER PHONE #: (703) 555-1212 
WORK ORDER #2.4 (TASK #5) 
ASKS: 
l Assign and remove BLFIDSS button assignments with CMC-211. 
‘ARAMETERS: NSTRUCTIONS: 
I) Assign the following features to the BLFIDSS 
installed in the previous task: 
BUTTON FEATURE 
1 DSS Park Answer 
2 DSS Camp On 
3 Alternate (assign directory 
number 212) 
4 Alarm 
5 
Night 
6 External Paging 
7 Automatic...

Page 172

eview Exercis - Programming Station 
Instruments an 
w/ 
IVIOdUl~S 
INSTRUCTIONS: THE FOLLOWING EXERCISE CONSISTS OF MULTIPLE CHOICE, TRUE/FALSE, FILL 
IN THE BLANK, OR MATCHING TYPE QUESTIONS. ALL AVAILABLE RESOURCES (I.S. STUDENT 
WORKBOOK, NOTES, AND GTEP MANUAL) MAY BE USED AS REFERENCES. SUBMIT EXERCISE TO 
INSTRUCTOR FOR GRADING WHEN LAST QUESTION HAS BEEN COMPLETED. 
1. IF YOU ATTEMPT TO ADD AN EKT STATION THROUGH PROGRAMMING BEFORE IT HAS BEEN 
WIRED, WHAT WILL OCCUR? (TRY THIS IN THE LAB TO...

Page 173

ewiew Exercise - 
rogramming Station 
and BLF/DSS Modules 
(2.2) 
6. MATCH THE DEFINITION OF EACH PARAMETER FOR CMC-201 TO ITS CORRECT LOCATIOti: 
Pl 
A. METERING GROUP NUMBER 
P2 B. TYPE OF DIALING 
P3 
C. DIRECTORY NUMBER 
P4 D. TENANT NUMBER 
P5 
E. OPERATION MODE 
7. WHAT IS THE DEFAULT OPERATION CODE FOR STATION INSTRUMENTS? 
A. BOTHWAY 
B. ORIGINATE ONLY 
C. TERMINATE ONLY 
D. BOTH RESTRICTED (ICM ONLY) 
8. WHAT DOES A P VALUE OF 3 INDICATE FOR CMC-201, PARAMETER 3? 
9. HOW COULD FIVE TENANT GROUPS...

Page 174

eview Exercise - 
rogramming Statisn 
11. lDENTlFY THE DEFAULT BUTTON ASSlGNMENTS USING FEATURE NUMBERS (FNO) FOR THE 
EKT BUTTON ON A CS-10 ASSIGNED TO A CIRCUIT ON CARD SLOT 01 
FNO: FNO: FNO: 
FNO: FNO: 
~ ___ ~ ___ - 
6 7 8 9 10 
FNO: FNO: FNO: 
FNO: FNO: 
__ - ___ ~ ___ ~ 
1 
2 3 4 5 
12. MATCH THE DEFINITION OF EACH PARAMETER WITH ITS CORRECT LOCATION IN CMC-203: 
PI 
A. RINGING MODE 
P2 B. FEATURE NUMBER 
P3 
C. STATION DIRECTORY NUMBER 
P4 D. LINE TERMINATION TYPE 
P5 E. BUTTON NUMBER 
P6 F....

Page 175

-. 
15. IDENTIFY AND DEFINE FIVE FEATURES THAT CANNOT BE ASSIGNED TO EKT BUTTONS: 
FNO 
DEFINITION 
16. WHAT IS THE FUNCTION OF CMC-203’s PARAMETER 6? 
THE FEATURE NUMBERS THAT REQUIRE A VALUE ASSIGNED TO THIS PARAMETER ARE 
I 
, , AND 
. 
17. THE PROGRAM FUNCTION KEY MUST BE USED BEFORE A BUTTON ASSIGNMENT 
CAN BE CHANGED. 
18. WHAT OCCURS IF A BLF/DSS IS ASSIGNED THROUGH USE OF CMC-210 BEFORE IT 
IS WIRED? (TRY THIS TO VERIFY). 
19. IF A BLF/DSS IS INSTALLED AFTER THE SYSTEM HAS BEEN INITIALIZED WITH A...

Page 176

22. MATCH THE DEFlNiTlON OF EACH PARAMETER WITH ITS CORRECT LOCATION IN CMC-210: 
Pl A. STATION DIRECTORY NUMBER OF EKT ATTACHED TO BLF/DSS 
P2 B. BLF/DSS TYPE 
P3 C. COPIED DSN 
P4 D. BLF/DSS MODULE NUMBER 
P5 E. EQUIPMENT NUMBER 
P6 F. 
BLF/DSS ORDER 
23. DESCRIBEJHETWO WAYS IN WHICH BUTTONS CAN BE ASSIGNED TO A BLF/DSS MODULE. 
(1) 
(2) 
24. A BLF/DSS CAN HAVE “DSS PARK” BUTTONS ASSIGNED TO IT. 
25. A BLF/DSS CAN HAVE “DSS CAMP ON” BUTTONS ASSIGNED TO IT. 
26. WHAT IS THE PURPOSE OF THE “ALTERNATE”...

Page 177

28. MATCH THE DEFINITION OF EACH PARAMETER WITH ITS CORRECT LOCAiiON IN CMC-211: 
Pl 
A. BUTTON NUMBER 
P2 B. STATION DIRECTORY NUMBER OF EKT ATTACHED TO BLF/DSS 
P3 C. TYPE OF DSS FEATURE ASSIGNMENT 
P4 D. DIRECTORY NUMBER 
P5 
E. RINGING MODE 
P6 
F. LINE TERMINATION TYPE FOR LINE ACCESS 
29. THE BLF/DSS MODULE BUTTON NUMBERING PLAN IS ORDERED: 
A. LEFT TO RIGHT DOWNWARD 
B. RIGHT TO LEFT DOWNWARD 
C. RIGHT TO LEFT UPWARD 
D. LEFT TO RIGHT UPWARD 
30. MATCH EACH OF THE FOLLOWING CMC COMMANDS WITH ITS...

Page 178

2.65  

Page 179

ATA BASE ADMINISTRATION 
Programming Basic 
Trunk Data 
2.66 
_’ 
,. .,  

Page 180

2.3 Enabling 0 ective 
GIVEN: 0 
e 
0 
0 
ACTION: 
0 
CRITERIA: 0 GTE OMNI SBCS 
GTE OMNI SBCS PERIPHERALS 
PORTABLE MAINTENANCE PANEL 
GTE OMNI SBCS COURSE AND SITE DOCUMENTATION 
PACKAGE 
LABORATORY ACTIVITY - PROGRAMMING BASIC TRUNK 
DATA 
REVIEW EXERCISE 
USE OMNI SBCS PROGRAMMING TOOLS AND EQUIPMENT 
TO: 
- INSTALL AND MODIFY BASIC TRUNK LINE DATA 
FOR CO, TIE, AND SCC. 
COMPLETE REVIEW EXERCISE. 
DEMONSTRATION OF ABOVE TASKS IN ACCORDANCE 
WITH PROCEDURES OUTLINED IN OMNI SBCS GTEP 
MANUAL AND OMNI...
Start reading GTE Omni Scbs Installation And Maintenance Manual

Related Manuals for GTE Omni Scbs Installation And Maintenance Manual

All GTE manuals