Page 131
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 3 - System Setup 3 - 7 3-3-4 Receiving the Vivid 7 3-3-4-1 Examine All Packages Examine all packages closely at time of de livery, as described in the procedure below. Table 3-5 Examine All Packages STEPTASKILLUSTRATIONS 1 Is damage apparent? • If yes; continue with the instructions in subsection 3-3-4-2 - Damage in Transportation . • If no; continue with the next step. 2 Is the Shock Indicator red colored inside the...
Page 132
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 3 - 8 Section 3-3 - Receiving and Unpacking the Equipment 3-3-4-2 Damage in Transportation Follow this procedure if damage is apparent, or if the Tilt & Drop Indicators show failure: Table 3-6 Damage in Transportation STEPTASK 1 Write “Damage In Shipment” on ALL copies of the freight or express bill BEFORE delivery is accepted or “signed for” by a GE representative or hospital receiving agent. 2 Report the damage to the...
Page 133
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 3 - System Setup 3 - 9 3-3-4-3 Vivid 7 Transportation Box Label The Vivid 7 Transportation Box Label is located at the front of the transportation box. Figure 3-3 Vivid 7 Transportation Box Label HANDLE WITH CARE KEEP DRY, PROTECT FROM MOISTURE TOP. UPRIGHT TRANSPORTATION & STORAGE RECYCLING. RECYCLABLE WOOD KEEP TRANSPORTATION TEMPERATURE BETWEEN -20°C and +60°C RELATIVE HUMIDITY BETWEEN 30 and 95% FRAGILE,...
Page 134
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 3 - 10 Section 3-3 - Receiving and Unpacking the Equipment 3-3-5 Unpacking Vivid 7 CAUTIONTwo people are needed to unpack the unit because of its weight. Attempts to move the unit considerable distances or on an incline by one person could result in injury or damage or both. Two people are required whenever a part weighing 16 kg (35 lbs) or more must be lifted or pushed up or down a slope. Table 3-7 Unpacking Vivid 7...
Page 135
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 3 - System Setup 3 - 11 4. • Press once on the brake pedal to release the brakes. • Keep direction lock activated. The direction lock keeps the fr ont wheels from swiveling and blocking the system inside the narrow transportation box. Table 3-7 Unpacking Vivid 7 (cont’d) StepTask Transport notice FC314187-03 NOTIC E M ovin g V iv id 7/L ogiq 9 i n a nd o ut o f t h e t r a nsp orta tio n b ox Vivid 7/Logiq 9 has...
Page 136
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 3 - 12 Section 3-3 - Receiving and Unpacking the Equipment 5.Carefully move the instrument out of the Transportation Box, down the ramp, with rear end first. 6.Vivid 7 with LCD: Remove part number 10 (LCD monitor enforcement). 7. Remove the clear plastic (wrapped around the scanner) from the unit. 8. Place all the filling material inside the Transportation Box, close it and store it for possible use in the future. Table 3-7...
Page 137
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 3 - System Setup 3 - 13 Section 3-4 Packing Materials - Re cycling Information The packing materials for Vivid 7 are recyclable: • The Transportation Box is made of spruce or similar material. (“PHYTOSANITARY CERTIFICATE” incl uded in all shipments to The Peoples Republic of China.) • Lever lockings (hinges) are made of zinc plated steel. • The inner reinforcements are made of Ethafoam (Polyethylene foam). • The plastic...
Page 138
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 3 - 14 Section 3-5 - Preparing for Setup Section 3-5 Preparing for Setup 3-5-1 Physical Inspection • Verify that the system arrive d intact (visual inspection). If the system has been damaged, please refer to “Damage in Transportation“ on page viii in the beginning of this manual. • Verify that all items are present (see the Pa cking List). Report any missing parts on the Post Delivery Checklist . 3-5-2 EMI Protection This unit...
Page 139
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL Chapter 3 - System Setup 3 - 15 3-6-2 Electrical Specifications 3-6-2-1 Verification of the System’s Voltage Settings Verify that the mains voltage specif ied for the unit is available on-site. The Voltage setting for the unit is found on a label ne ar the Mains Power Circuit Breaker at the rear of the system, see Figure 3-4 on page 3-15 . See also Table 3-10 Electrical Specifications for Vivid 7 on page 3-16 ....
Page 140
GE HEALTHCARE DIRECTION FC091194, REVISION 11 VIVID 7 SERVICE MANUAL 3 - 16 Section 3-5 - Preparing for Setup 3-6-2-2 Electrical Specifications for Vivid 7 Table 3-10 Electrical Specifications for Vivid 7 sheet 1 of 3 GE VINGMED PART NUMBER DESCRIPTIONVOLTAGETOLERANCESCURRENTFREQUENCY FD000010 VIVID 7 DIMENSION CONSOLE, LCD MONITOR 230 VAC ±10% 5 A 50-60 Hz FD000020 VIVID 7 DIMENSION CONSOLE, LCD MONITOR 100-120 VAC ±10% 10 A 50-60 Hz FD000120 VIVID 7 PRO CONSOLE, LCD MONITOR 230 VAC ±10%...