Page 191
Service Menu 71 Document no. M1031519-01 4.15.1 Sensor Sensor Service data is changed to the sensor view. Entropy refers to the respective module key. Is highlighted when the Entropy key is pressed on the module. (Opens the Entropy menu.) Check Sensor is highlighted when the Check Sensor key is pressed on the module. Activates the sensor check. Cable indicates whether the Entropy sensor cable is connected to the module or not. Sensor indicates whether the...
Page 192
Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors 72 Document no. M1031519-01 4.16 DIS Interfacing 4.16.1 Interfacing How to interface To select the parameter data source: •Press the Monitor Setup and select Interfacing. •Select the desired measurement parameter, for example Gases. •Select the desired source by name, for example Aest. NOTE: The name of the device is visible on the list only if the device is...
Page 193
Service Menu 73 Document no. M1031519-01 4.16.2 Status Page 4.16.3 DIS Interfacing Access via Monitor setup - Interfacing. The selection Next page is available, if more than 8 DIS modules are connected to the DIS bus simultaneously. Interfaces The menu displays a list of all connected DIS modules and the statuses of the corresponding external devices. If the bus voltage is too low, you cannot add more devices. ‘DIS module bus voltage low. Do not add more...
Page 194
Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors 74 Document no. M1031519-01 DIS Module specific page Service Data Product name: DIS module name. Product type: DIS module type. Driver sw id: DIS module software and its release date. Short product name: DIS module name. Module serial number: DIS module serial number. HW card type: PCB type. HW id: DIS module PCB identification number. HW test date: DIS...
Page 195
Service Menu 75 Document no. M1031519-01 5 Set/Test In the power supply unit, there is a safety element, which needs refreshing at least every 1.5 seconds. If the main CPUs software will not refresh, safety element gives reset to main CPU. In normal operation the main CPUs software refreshes safety element every 0.2 seconds. The purpose of the safety element is to restart the monitor if there is a serious malfunction. This feature is useful in two cases:...
Page 196
Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors 76 Document no. M1031519-01 5.1 Country Settings Language Select the software language. National Reqs Select the software features, which include national requirements. Power Frequency Set the power frequency (50 Hz/60 Hz). This setting is used to filter out possible power frequency interference from the parameter measurements. Time format Set the time...
Page 197
Service Menu 77 Document no. M1031519-01 6 Service Log Error, event, alarm and maintenance data is stored in Service Log. The service log contains information about the occurred monitor errors, events and alarms since the last factory reset or service log reset. The service log is saved in the EEPROM memory of the main CPU board. The user can also store different maintenance events in the maintenance log. Maintenance menu is for setting and viewing the...
Page 198
Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors 78 Document no. M1031519-01 6.1 Maintenance 6.1.1 Planned Maintenance The Maintenance History Log gives the user a possibility to store the maintenance history of the monitor. The user can store different planned maintenance (PM) events, repairs and upgrades in the maintenance history log. Running hours: shows how many hours the monitor has been on. User...
Page 199
Service Menu 79 Document no. M1031519-01 6.1.2 Repair 6.1.3 Upgrade The repair menu gives the user a possibility to store re- pair events in the maintenance history log. The different repairs that can be saved are: Display, Power Supply, Recorder, Frame (e.g. board in the frame), Parame- ters (e.g. a board in the parameter module) or Other (a miscellaneous repair not specified by previous op- tions). The upgrade menu gives the user a possibility to store the...
Page 200
Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors 80 Document no. M1031519-01 6.2 Error History 6.3 Event History Last Errors: The section shows the last monitor errors and the time of their occurence. Error counters: The section contains counters for each different (detected) monitor error. The time of occurrence of the last error is shown beside each counter. Last log reset: The date and time of the last...