CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-19 3.1.7.3 System setup menu (*) indicates online only, (**) indicates offline only 3.1.7.4 Breaker menu 3.1.7.5 Protection elements menu This option shows all protection elements available in the relay as shown in the following two tables (exact menu depends on firmware version). For firmware versions below 7.50, each gr oup of protection elements includes the specific...
Page 82
3-20F650 DIGITAL BAY CONTROLLER GEK-113000-AF 3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES For firmware version 7.50 and above, there are six setting g roups of protection elements. Protection element groups are within each setting group. Table 3-5: Protection elements menu, f irmware version 7.50 or above (*) indicates online only, (**) indicates offline only For firmware version 7.5 and above, the specific protection element menus shown are available under each...
Page 83
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-21 Firmware version 7.50 and above also include Frequency and Miscellaneous menus in the Protection Element section. Phase OVPhase overvoltage (59P) Neutral OV HighNeutral overvoltage, high level (59NH) Neutral OV LowNeutral overvoltage, low level (59NL) Negative Sequence OVNegative sequence overvoltage (47) Auxiliary OVAuxiliary overvoltage (59X) Auxiliary UVAuxiliary...
Page 84
3-22F650 DIGITAL BAY CONTROLLER GEK-113000-AF 3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1.7.6 Control elements menu This option shows all protection elements available in the relay as shown in the following two tables (exact menu depends on firmware version). Table 3-7: Control elements menu, f irmware version below 7.50 Control Elements Setting Group Control elements can be used in either a single setting group (default mode-all units can op erate...
Page 85
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-23 Table 3-8: Control elements menu, f irmware version 7.50 and above 3.1.7.7 Inputs/Outputs menu Section that contains the settings for all input and output boards and the Force Outputs and Virtual inputs activation tools. (*) indicates online only, (**) indicates offline only This section shows the settings related to inputs and outputs for the different boards available in...
Page 86
3-24F650 DIGITAL BAY CONTROLLER GEK-113000-AF 3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1.7.8 Quick settings menu This menu allows quick access to the main Setpoints of the relay. Figure 3-10: Quick Settings 3.1.7.9 Relay conf iguration menu This is the relay configuration section in which the relay ca n be configured using internal states or already compiled equation on PLC Editor . Relay Conf iguration OutputsConf iguration of contact output operate and...
Page 87
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-25 The following figures show an example of the default factory configuration for F650: Figure 3-11: Relay conf iguration SwitchgearUp to 16 configurable switchgear elements. A switchgear element can be a breaker, a line se lector switch, a grounding selector switch, a busbar selector switch, etc. This screen allows conf iguration of type of contacts, opening and closing time,...
Page 88
3-26F650 DIGITAL BAY CONTROLLER GEK-113000-AF 3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES Figure 3-12: HMI conf iguration 3.1.7.10 Logic Conf iguration menu This logic configuration allows creating more complex configurations, using the graphical PLC, than using the tables from Relay Configuration. For file management detailed information go to section 3.1.4 File management menu. File description: *.pep:Header for Logic project: PLC project file containing the...
Page 89
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-27 3.1.7.11 IEC 103 Conf iguration menu This menu allows to update the IEC 103 configuration of the unit. Figure 3-13: IEC 103 Conf igurator See chapter 5.13 3.1.7.12 Clock menu This menu allows updates to the date and time of the relay, either synchronizing them with the PC clock, or entering the information manually. Figure 3-14: Clock
Page 90
3-28F650 DIGITAL BAY CONTROLLER GEK-113000-AF 3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1.8 Actual values menu The menu bar in the main screen of EnerVista 650 Setup software shows the ACTUAL menu option. This option concentrates and displays all the status of protection, control elements, metering, counters information, oscillography, events, fault locator, etc. This section shows only the structure of menus in EnerVista 650 Setup. 3.1.8.1 Front panel The...