GE F650 Manual
Here you can view all the pages of manual GE F650 Manual. The GE manuals for Controller are available online for free. You can easily download all the documents as PDF.
Page 91
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-29 Table 3-9: Protection elements, actual values menu Table 3-10: Control elements, actual values menu, f irmware versions below 7.50 Protection Protection BlocksThis screen shows all the protection element blocks available. Protection elements block si gnals can be conf igured at Setpoint > Relay Conf iguration > Protection Elements . Phase CurrentProtection status signals...
Page 92
3-30F650 DIGITAL BAY CONTROLLER GEK-113000-AF 3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES Table 3-11: Control elements, actual valu es menu, f irmware version 7.50 and above Table 3-12: Records status, actual values menu 3.1.8.3 Metering The Metering menu includes all the measurements available in the device. Primary and secondary values, and also the data related to the recording functions in the relay Control Elements Frequency Status signals (pickups and...
Page 93
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-31 3.1.8.4 Inputs/Outputs menu The Inputs/Outputs menu includes all the inputs and outputs signals available in the device. Contact and virtual type. (*) indicates online only, (**) indicates offline only 3.1.8.5 Records menu The Records menu is only available in online mode and includes the possibility to retrieve all the records available in the device. By serial or...
Page 94
3-32F650 DIGITAL BAY CONTROLLER GEK-113000-AF 3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1.9 Operations menu Option only available in online mode, showing all the operations previously configured in the relay with their corresponding texts, which must be different from the default text (Op_X not configured). (*) indicates online only, (**) indicates offline only 3.1.10 Communications menu The communication menu includes the computer screen to start...
Page 95
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-33 CAUTIONCAREFULLY READ THE FLASH MEMORY UPDATE PROCEDURE DESCRIBED IN SECTION “BOOT CODE AND FIRMWARE AND CLOSE ALL RUNNING APPLICATIONS BEFORE PERFORMING FIRMWARE AND OPERATING SYSTEM UPDATES. NOTICEFor f irmware versions below 7.00, check that the f irmware version that is going to be updated matches the operating system version of the relay before updating f irmware. If...
Page 96
3-34F650 DIGITAL BAY CONTROLLER GEK-113000-AF 3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES An example of Communication > Troubleshooting follows : Figure 3-15: Communication troubleshooting example 3.1.11 Security menu The security menu includes all the menus related to security control in EnerVista 650 Setup. EnerVista 650 Setup security users and passwords are not related to passwords in HMI. Ea ch security level has its own access for HMI management and...
Page 97
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-35 3.1.12 View menu The view menu includes the computer screen to start communicating with the relay, the different update procedures available in device: firmware, operating system, web server and other file storing capabilities (upload and download info files to/from relay). The ModBus memory map is detailed in the complete instruction manual (English only) and can be...
Page 98
3-36F650 DIGITAL BAY CONTROLLER GEK-113000-AF 3.2 HUMAN-MACHINE INTERFACE (HMI)CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.2 Human-machine interface (HMI) The HMI interface consists of several functional panels. Th e faceplate can be unscrewed to allow easy access to the removable modules. There is also a removable dust cover that fits over the display and other cover that protects the front RS232 Communications port and the commands buttons that can be sealed. The following figure shows the...
Page 99
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.2 HUMAN-MACHINE INTERFACE (HMI) GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-37 Figure 3-17: Enhanced HMI interface 3.2.1 Display F650 units are available with two different options for the front display. The first option is an alphanumerical display of 4 lines with 20 characters each, and the second option is a graphical display of 16 lines wi th 40 characters each (128x240 pixels). The boot code and firmware versions can be seen in the relay text...
Page 100
3-38F650 DIGITAL BAY CONTROLLER GEK-113000-AF 3.2 HUMAN-MACHINE INTERFACE (HMI)CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.2.2 LED indicators The relay provides 16 LED indicators, 15 user programmable pl us one non-configurable LED (READY) that shows if the relay is in service. Programmable LEDs are divided into groups of 5 LEDs, each of the groups having a different color. The first group of LED indicators is latched by hardware (red), usually configured for trip signals. The second group...
All GE manuals