Page 131

CHAPTER 3:  INTERFACES, SETTINGS & ACTUAL VALUES 3.3 WEB SERVER
GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-69
3.3.4  Alarms
The alarms screen provides access to alarms configured in the relay. As in the case of snapshot events and control events, 
this screen allows only to view the alarms, but not to acknowledge them.
Figure 3-42: Alarms screen 

Page 132

3-70F650 DIGITAL BAY CONTROLLER GEK-113000-AF
3.3 WEB SERVERCHAPTER 3:  INTERFACES, SETTINGS & ACTUAL VALUES
3.3.5  Oscillography
The oscillography screen allows obtaining from the relay available oscillography records in that moment.
This screen includes two windows. The first window shows oscillography records available in the relay, identified by an 
index, being the highest index the most recent record  (oscillography record No 6 in the example below).
Figure 3-43: Oscillography screen
If the user...

Page 133

CHAPTER 3:  INTERFACES, SETTINGS & ACTUAL VALUES 3.3 WEB SERVER
GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-71
3.3.6  Fault report
The fault report screen provides access to the last 10 fault reports obtained by the relay. These records are stored 
according to an index that marks their position among all records produced in the relay, with a range from 1 to 999, 
returning to 1 in case of exceeding the limit of 999. As in th e case of oscillography records, the highest index corresponds 
to the most...

Page 134

3-72F650 DIGITAL BAY CONTROLLER GEK-113000-AF
3.3 WEB SERVERCHAPTER 3:  INTERFACES, SETTINGS & ACTUAL VALUES
3.3.7  Data logger
The data logger screen allows viewing the data logger first and la st value retrieval date and allows downloading the data record 
files in Comtrade format, by pressing the Download option. Stored files can be viewed later using any Comtrade format viewer.
Figure 3-46: Data logger screen 

Page 135

GEK-113000-AFF650 DIGITAL BAY CONTROLLER 4-1
F650 Digital Bay Controller
Chapter 4:  Security
GE
Grid Solutions
SECURITY
4.1  Adding users
New users can only be added by users that have Administrator Access (or Admin Rights). The Enable Security check box 
located in the Security > User Management window must be enabled.
Remember: (In order to add new users and assign user rights ) 
•must be logged in with  Administrator Permission  
• and  
Enable Security  checkbox must be enabled    
4.1.1  User...

Page 136

4-2F650 DIGITAL BAY CONTROLLER GEK-113000-AF
4.2 CHANGING PASSWORDS CHAPTER 4:  SECURITY
4.2  Changing passwords
Users are prompted to change their password after the first successful log in or through clicking Security from the toolbar, and choose Change Password.
Figure 4-1: Change security
When the operator enters a new password for the first time, he/she should also enter a personal question that only they 
can answer. There is a limit of 50 characters available to enter the personal question. One...

Page 137

CHAPTER 4:  SECURITY4.3 ENABLING SECURITY
GEK-113000-AFF650 DIGITAL BAY CONTROLLER 4-3
4.3  Enabling security
EnerVista 650 Setup Security Control is disabled by default. Users dont have to log in through user name and password 
after installation and are granted access as Administrator. 
Security Control can be enabled through Security from the tool bar when logged on as an Administrator. Click 
User Management: 
Figure 4-2: Enabling security
Security Control is enabled by checking the ENABLE SECURITY...

Page 138

4-4F650 DIGITAL BAY CONTROLLER GEK-113000-AF
4.4 LOGGING INTO ENERVISTA 650 SETUP CHAPTER 4:  SECURITY
4.4  Logging into EnerVista 650 Setup
Users have to log on in order to use EnerVista 650 Setup program after Security Control has been enabled. After the start 
up of EnerVista 650 Setup, a dialog prompts for user name and password. 
Figure 4-3: Login user
The user name field displays the last log in user name as defa ult, in this example, TestUser. For the first log in session of 
any user name, the...

Page 139

GEK-113000-AFF650 DIGITAL BAY CONTROLLER 5-1
F650 Digital Bay Controller
Chapter 5:  Bootcode and firmware upgrade
GE
Grid Solutions
BOOTCODE AND FIRMWARE UPGRADE
5.1  Firmware upgrade versions below 7.00.
This section explains how to upgrade the F650 boot code and firmware for version below 7.00. 
The boot code and firmware versions can be seen in the relay main screen: The relay firmware version appears after the 
text “F650“(5.70 in Figure 5-1: Main screen) with the boot program version (6.00 in...

Page 140

5-2F650 DIGITAL BAY CONTROLLER GEK-113000-AF
5.1 FIRMWARE UPGRADE VERSIONS BELOW 7.00. CHAPTER 5:  BOOTCODE AND FIRMWARE UPGRADE
BOOT CODE RELEASE NOTES
It is mandatory to maintain version compatibility between fi rmware and boot code in the upgrade procedure, otherwise 
the relay does not start after upgrading.
FIRMWARE BOOTWARE AND 650 PC PROGRAM VERSIONS COMPATIBILITYFIRMWARE CODEBOOT CODEENERVISTA 650 PC5.726.007.205.70...