Page 61
CHAPTER 2: PRODUCT DESCRIPTION 2.6 EXTERNAL CONNECTIONS GEK-113000-AF F650 DIGITAL BAY CONTROLLER 2-31 Figure 2-3: Input/output conf igur ations for boards F1 and F2 (189C4216H1) F1 + CC1 91F b25 F2 + CC2 02F KCOLB P05 F3 + CC3 12F KCOLB P15 F4 + CC4 22F KCOLB P76 F5 + CC5 32F KCOLB G05 F6 + CC6 42F KCOLB G15 F7 + CC7 52F ETAITINI 97 F8 + CC8 62F KCOLB 97 F9 - COMMON 1/8 COMMON 1/8 F27 F10 - COMMON 9/16 COMMON 9/16 F28 F11 + CC9 NOT USED F29 F12 + CC10 NOT USED F30 F13 + CC11 NOT USED F31 F14 + CC12...
Page 62
2-32F650 DIGITAL BAY CONTROLLER GEK-113000-AF 2.6 EXTERNAL CONNECTIONS CHAPTER 2: PRODUCT DESCRIPTION
Page 63
GEK-113000-AFF650 DIGITAL BAY CONTROLLER 3-1 F650 Digital Bay Controller Chapter 3: Interfaces, Settings & Actual Values GE Grid Solutions INTERFACES, SETTINGS & ACTUAL VALUES 3.1 EnerVista 650 Setup software 3.1.1 Introduction The EnerVista 650 Setup software provides a graphical user interface (GUI) as one of two direct interfaces with a 650 device. The alternate interface is implemented via the device faceplate keypad and display (see the Human Machine Interface (HMI) section in this chapter)....
Page 64
3-2F650 DIGITAL BAY CONTROLLER GEK-113000-AF 3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1.1.1 Using settings f iles The EnerVista 650 Setup software interface supports three ways of handling changes to relay settings: 1. In offline mode (relay disconnected), create or edit relay settings f iles for later download to communicating relays. 2. In online mode (relay connected), modify any relay settings via relay data view windows, and then save the settings to...
Page 65
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-3 3.1.2 Main screen The EnerVista 650 Setup software main window includes the following components: • T itle bar • Main menu bar • Main icon bar •Working area • Status bar Figure 3-1: EnerVista 650 Setup main screen Working Area Title
Page 66
3-4F650 DIGITAL BAY CONTROLLER GEK-113000-AF 3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1.3 Connect to the relay To start communicating with the relay go to Communication > Computer in the main EnerVista 650 Setup menu. When working online, ensure that all relay communication parameters, such as baud rate, slave ModBus address, etc., match the computer settings before connected to the relay. Figure 3-2: Communica tion parameters menu The Communication >...
Page 67
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-5 3.1.3.1 Computer Settings: This section shows the communication parameters needed to establish communication with the unit, such as slave address, communication port, baud rate, parity, control type and startup mode. Baud rate, parity, data bits, stop bits and ModBus slave address for Com2 (RS232 front port and second serial port in the rear communication board) are displayed...
Page 68
3-6F650 DIGITAL BAY CONTROLLER GEK-113000-AF 3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1.4 File management menu File management with EnerVista 650 Setup software: 3.1.4.1 Offline mode Figure 3-3: Offline mode f ile management1 1. “Relay and logic configuration” and “Protection and Contro l Settings” must be uploaded to the F650 relay or the device to operate properly Run EnerVista 650 Setup Open a *.650 file (“File>Open” menu) Modify Settings and relay...
Page 69
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-7 Table 3-1: Types of f iles generated by EnerVista 650 Setup software, offline: When using element libraries (both pre-existing in File Library > Open Library or created by the user in File Library > New Library), the program creates and manages the corresponding files (*.lib) in a folder named FDB (Functional Block Diagram). These files are used for PLC project compilation....
Page 70
3-8F650 DIGITAL BAY CONTROLLER GEK-113000-AF 3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1.4.2 Online mode Figure 3-4: Online mode f ile management NO Run EnerVista 650 Setup Connect to the relay (“Communication>Computer>ON”) Modify and send to the relay protection Settings and rela y configuration Is it necessary to program additional logic? Launch the Logic Configuration tool in EnerVista 650 Setu p(“Setpoint>Logic Configuration ”) Create new or modify...