CHAPTER 2:  PRODUCT DESCRIPTION 2.6 EXTERNAL CONNECTIONS
GEK-113000-AF F650 DIGITAL BAY CONTROLLER 2-31
Figure 2-3: Input/output conf igur ations for  boards F1 and F2 (189C4216H1)
F1 + CC1
91F
b25
F2 + CC2 02F
KCOLB P05
F3 + CC3 12F
KCOLB P15
F4 + CC4 22F
KCOLB P76
F5 + CC5 32F
KCOLB G05
F6 + CC6 42F
KCOLB G15
F7 + CC7 52F
ETAITINI 97
F8 + CC8 62F
KCOLB 97
F9 - COMMON 1/8 COMMON 1/8 F27
F10 - COMMON 9/16 COMMON 9/16 F28
F11

+ CC9 NOT USED
F29
F12 + CC10 NOT USED
F30
F13 + CC11 NOT USED
F31
F14 + CC12...

Page 62

2-32F650 DIGITAL BAY CONTROLLER GEK-113000-AF
2.6 EXTERNAL CONNECTIONS CHAPTER 2:  PRODUCT DESCRIPTION 

Page 63

GEK-113000-AFF650 DIGITAL BAY CONTROLLER 3-1
F650 Digital Bay Controller
Chapter 3:  Interfaces, Settings & Actual Values
GE
Grid Solutions
INTERFACES, SETTINGS & ACTUAL VALUES 
3.1  EnerVista 650 Setup software 
3.1.1  Introduction
The EnerVista 650 Setup software provides a graphical user interface (GUI) as one of two direct interfaces with a 650 
device. The alternate interface is implemented via the device faceplate keypad and display (see the Human Machine 
Interface (HMI) section in this chapter)....

Page 64

3-2F650 DIGITAL BAY CONTROLLER GEK-113000-AF
3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3:  INTERFACES, SETTINGS & ACTUAL VALUES
3.1.1.1  Using settings f iles
The EnerVista 650 Setup software interface supports three ways of handling changes to relay settings:
1. In offline mode (relay disconnected), create or edit relay settings f iles for later download to communicating relays.
2. In online mode (relay connected), modify any relay settings  via
  relay data view windows, and then save the settings to...

Page 65

CHAPTER 3:  INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE
GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-3
3.1.2  Main screen
The EnerVista 650 Setup software main window includes the following components:
• T itle bar
• Main menu bar
• Main icon bar
•Working area
• Status bar
Figure 3-1: EnerVista 650 Setup main screen
Working Area
 Title 

Page 66

3-4F650 DIGITAL BAY CONTROLLER GEK-113000-AF
3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3:  INTERFACES, SETTINGS & ACTUAL VALUES
3.1.3  Connect to the relay
To start communicating with the relay go to Communication > Computer in the main EnerVista 650 Setup menu. 
When working online, ensure that all relay communication parameters, such as baud rate, slave ModBus address, etc., 
match the computer settings before connected to the relay. 
Figure 3-2: Communica tion parameters menu
The Communication >...

Page 67

CHAPTER 3:  INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE
GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-5
3.1.3.1  Computer Settings:
This section shows the communication parameters needed to establish communication with the unit, such as slave 
address, communication port, baud rate, parity, control type and startup mode.
Baud rate, parity, data bits, stop bits and ModBus slave address for Com2 (RS232 front port and second serial port in the 
rear communication board) are displayed...

Page 68

3-6F650 DIGITAL BAY CONTROLLER GEK-113000-AF
3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3:  INTERFACES, SETTINGS & ACTUAL VALUES
3.1.4  File management menu
File management with EnerVista 650 Setup software:
3.1.4.1  Offline mode
Figure 3-3: Offline mode f ile management1
 1. “Relay and logic configuration” and “Protection and Contro l Settings” must be uploaded to the F650 relay or the device 
to operate properly
Run EnerVista 650 Setup
Open a *.650 file (“File>Open” menu)
Modify  Settings and relay...

Page 69

CHAPTER 3:  INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE
GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-7
Table 3-1: Types of f iles generated by EnerVista 650 Setup software, offline: 
When using element libraries (both pre-existing in File Library > Open Library or created by the user in File Library > New 
Library), the program creates and manages the corresponding files (*.lib) in a folder named FDB (Functional Block 
Diagram). These files are used for PLC project compilation....

Page 70

3-8F650 DIGITAL BAY CONTROLLER GEK-113000-AF
3.1 ENERVISTA 650 SETUP SOFTWARECHAPTER 3:  INTERFACES, SETTINGS & ACTUAL VALUES
3.1.4.2  Online mode 
Figure 3-4:  Online mode f ile management
NO
Run  EnerVista 650 Setup
Connect to the relay 
(“Communication>Computer>ON”)
Modify and send to the 
relay protection Settings 
and rela
y configuration
Is it necessary to  program 
additional logic?
Launch the Logic Configuration tool in EnerVista  650 Setu
p(“Setpoint>Logic Configuration ”)
Create new or modify...