Page 81
AcuLaser M4000 Series Users Guide Using the Control Panel81 Cancel Print Job (by host) The print job is canceled at the printer driver. Can’t Print The print data is deleted because it is incorrect. Make sure the appropriate paper size and printer driver are used. Can’t Print Duplex The printer has encountered problems during duplex printing. Make sure you are using an appropriate type and size of paper for the duplex printing. The problem could also be a result of incorrect settings for the paper...
Page 82
AcuLaser M4000 Series Users Guide Using the Control Panel82 Check Paper Type The paper loaded in the printer does not match the paper type setting in the printer driver. Paper that matches only the paper size setting will be used for printing. To clear this error, select Clear Warning from the control panel’s Reset Menu. See “How to access the control panel menus” on page 53 for instructions. Collate Disabled Printing by specifying the number of copies is no longer possible due to a lack of memory...
Page 83
AcuLaser M4000 Series Users Guide Using the Control Panel83 Feed Roller C2 Needed Soon, Feed Roller C3 Needed Soon This message indicates that the feed roller C2 or C3 is near the end of its service life. You can continue to print until the Replace Feed Roller C2 or Replace Feed Roller C3 message appears. Prepare a new feed roller. To clear this warning message and continue printing, select Clear All Warnings from the control panel’s Reset Menu. For instruction about accessing the control panel menus,...
Page 84
AcuLaser M4000 Series Users Guide Using the Control Panel84 HDD CHECK The printer is checking the Hard Disk Drive. Image Optimum There is insufficient memory to print the page at the specified print quality. The printer automatically lowers the print quality so that it can continue printing. If the quality of the printout is not acceptable, try simplifying the page by limiting the number of graphics or reducing the number and size of fonts. To clear this error, select Clear Warning from the control...
Page 85
AcuLaser M4000 Series Users Guide Using the Control Panel85 Maintenance unit Needed Soon This message indicates that the maintenance unit is near the end of its service life. You can continue to print until the Replace Maintenance Unit message appears. Prepare a new maintenance unit. To clear this warning message and continue printing, select Clear All Warnings from the control panel’s Reset Menu. For instruction about accessing the control panel menus, see “How to access the control panel menus” on...
Page 86
AcuLaser M4000 Series Users Guide Using the Control Panel86 Optional RAM Error The optional memory module may be corrupted or incorrect. Replace it with a new one. Outbin Select Error The specified paper size or paper type cannot be output to the face-up tray. Change the paper size or paper type, or select the face-down tray as the output tray. Paper Jam WWWW The location where the paper jam occurred is displayed at WWWWW. WWWWW indicates the location of the error. If a paper jam occurs at two or more...
Page 87
AcuLaser M4000 Series Users Guide Using the Control Panel87 Paper Set tttt sssss The paper loaded in the specified paper source (tttt) does not match the required paper size (sssss). Replace the loaded paper with the correct size paper and press the Start/Stop button to resume printing, or press the +Cancel Job button to cancel the print job. If you press the Start/Stop button without replacing the paper, the printer will print on the loaded paper even though it does not match the required size....
Page 88
AcuLaser M4000 Series Users Guide Using the Control Panel88 Replace Fuser The fuser has reached the end of its service life and needs to be replaced. Turn the printer off and wait for 30 minutes, then replace the fuser unit with a new one. See “Fuser Unit” on page 126 for instructions. Replace Maintenance Unit The maintenance unit has reached the end of its service life and needs to be replaced. If this error occurs, consult your dealer. Replace Toner Cartridge The imaging cartridge has reached the end...
Page 89
AcuLaser M4000 Series Users Guide Using the Control Panel89 ROM CHECK The printer is checking the ROM. SELF TEST The printer is currently performing a self test and initialization. Service Req Cffff/Service Req Exxx A controller error or a print engine error has been detected. Turn off the printer. Wait at least 5 seconds, then turn it back on. If Service Req E300 appears, confirm that the fuser unit is installed correctly. If the error message still appears, write down the error number listed on the...
Page 90
AcuLaser M4000 Series Users Guide Using the Control Panel90 Toner Low This message indicates that the imaging cartridge is near the end of its service life. Prepare a new imaging cartridge. Note: Replacement of the imaging cartridge is not yet necessary when the Toner Low message appears. Toner may remain in the imaging cartridge and spill out if you remove the imaging cartridge at this level. Unable Clear Error The printer cannot clear an error message because the error status still remains. Try...