8. Pull down the handle on the toner cartridge until the toner cartridge is unlocked and moves out slightly toward you. Remove the toner cartridge. Note: Do not manually rotate the toner cartridge carousel. In addition, do not rotate the carousel with force, otherwise it may be damaged. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Replacing Consumables 121
Note: ❏Do not touch the contact indicated in the illustration. ❏Dispose of the empty toner cartridge according to your local regulations. Do not burn the toner cartridge. For details, refer to “About Toner Cartridges” on page 117. 9. Check the color of the new toner cartridge to be installed. 10. Remove the toner cartridge from the bag. 11. Shake the cartridge a few times to distribute the toner. Note: Make sure that the toner roller cover is securely attached before shaking the toner cartridge. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Replacing Consumables 122
12. Remove the cover from the toner roller. Note: Do not touch or scratch the toner roller. 13. Align the shaft on each end of the toner cartridge with its holders, and then insert the cartridge. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Replacing Consumables 123
Note: Before inserting the toner cartridge, make sure that the color of the toner cartridge to be installed is the same as the label on the toner cartridge carousel. Note: Do not touch the contact indicated in the illustration. 14. Press in the toner cartridge until it locks into place. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Replacing Consumables 124
15. Close the front cover. 16. Press the Stop/Reset key to reset the machine and clear the indicator message. Note: The machine must complete a calibration cycle after a toner cartridge has been replaced. If you open the scanner unit or front cover before the machine is reset, the calibration stops, then starts over again after the cover is closed. Removing All Toner Cartridges Note: Be careful not to spill toner while removing a toner cartridge. If toner spills, immediately wipe it off with a soft, dry cloth. By selecting the EJECT MODE in the PRINTER MODE menu, all toner cartridges can be removed. Follow the procedure described below to use the EJECT MODE. 1. With the main screen displayed, press the l key to display the PRINTER MODE screen. 2. Press the d key to select T/C CHANGE and then press the Select key. 3. Press the d key to select EJECT MODE and then press the Select key. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Replacing Consumables 125
4. Open the front cover. Note: Before opening the front cover, open Tray 1 if it is not already open. 5. Pull down the handle on the toner cartridge until the toner cartridge is unlocked and moves out slightly toward you. Remove the toner cartridge. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Replacing Consumables 126
Note: Do not manually rotate the toner cartridge carousel. In addition, do not rotate the carousel with force, otherwise it may be damaged. Note: Do not touch the contact indicated in the illustration. 6. Close the front cover. Note: To exit EJECT MODE, press the Stop/Reset key. 7. Follow the same procedure to remove the cartridges for the cyan, black, then yellow toners. 8. Press the Stop/Reset key to reset the machine. Replacing the Photoconductor Unit Part Name Photoconductor Unit Part Number Photoconductor Unit 1198 Note: ❏For optimum print quality and performance, use only the corresponded TYPE genuine Epson photoconductor unit. ❏You are advised to replace the photoconductor unit when the message P/U LIFE END/REPLACE P/U appears. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Replacing Consumables 127
1. Open the scanner unit. Note: If there is paper in the output tray, remove it, and then fold up the output tray before opening the scanner unit. Note: Do not touch the wires and flat cable shown in the illustration. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Replacing Consumables 128
2. Grab the handle and lift it up slightly to the back, and then slowly pull the photoconductor unit out vertically. Note: Dispose of the used photoconductor unit according to your local regulations. Do not burn the photoconductor unit. 3. Prepare the new photoconductor unit. Note: Do not touch the PC drum and the transfer belt on the photoconductor unit. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Replacing Consumables 129
4. Slowly insert the new photoconductor unit vertically, and then push it slightly down toward you to finish installing the photoconductor unit. 5. Carefully close the scanner unit. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Replacing Consumables 130