Chapter 2.5 Compaq Diagnostics A Compaq Diagnostics diskette is supplied with the computer. Run the Diagnostics utilities when you want to view or test system information and installed or connected devices. The Diagnostics menu includes the following utilities: o Computer Checkup (TEST) o View System Information (INSPECT) If you have a problem you cannot solve, run the Diagnostics utilities before you call for support. Run Computer Checkup and select to save the device list to a file and to print or to save the log of errors. Run the View System Information (INSPECT) utility and select to print or to save that information. Have the files or the printed information available when you call for support. 2.5.1 Computer Checkup (TEST) Computer Checkup (TEST) determines whether the various computer components and devices are recognized by the system and are functioning properly. You can display, print, or save the information generated by Computer Checkup. Follow these steps to run Computer Checkup: 1. Plug the computer into an external power source. (A low battery condition could interrupt the program.) 2. Turn on the external devices that you want to test. Connect the printer if you want to print a log of error messages. 3. Insert the Compaq Diagnostics diskette in drive A. 4. Turn on or restart the computer. The computer starts from drive A, and the Diagnostics Welcome screen appears. 5. Press Enter to continue. The Diagnostics menu appears. 6. Select Computer Checkup from the Diagnostics menu. A Test Option menu appears. 7. Select View the Device List from the Test Option menu. A list of the installed Compaq devices appears. 8. If the list of installed devices is correct, select OK. The Test Option menu appears. NOTE: If the list is incorrect, ensure that any new devices are installed properly.
9. Select one of the following from the Test Option menu: o Quick Check Diagnostics. Runs a quick, general test on each device with a minimal number of prompts. If errors occur, they display when the testing is complete. You cannot print or save the error messages. o Automatic Diagnostics. Runs unattended, maximum testing of each device with minimal prompts. You can choose how many times to run the tests, to stop on errors, or to print or save a log of errors. o Prompted Diagnostics. Allows maximum control over testing the devices. You can choose attended or unattended testing, decide to stop on errors, or choose to print or save a log of errors. 10. Follow the instructions on the screen as the devices are tested. When testing is complete, the Test Option menu appears. 11. Exit the Test Option menu. 12. Exit the Diagnostics menu. 2.5.2 View System Information (INSPECT) The View System Information (INSPECT) utility provides information about the computer and installed or connected devices. You can display, print, or save the information. Follow these steps to run View System Information (INSPECT) from the Compaq Diagnostics diskette: 1. Turn on the external devices that you want to test. Connect the printer if you want to print the information. 2. Insert the Compaq Diagnostics diskette in drive A. 3. Turn on or restart the computer. The computer starts from drive A, and the Diagnostics Welcome screen appears. 4. Press Enter to continue. The Diagnostics menu appears. 5. Select View System Information (INSPECT) from the Diagnostics menu. 6. Select the item you want to view from the following list: =========================================================================== System Memory ROM Audio Keyboard Operating system System ports System files System storage Windows files
Graphics =========================================================================== 7. Follow the instructions on the screen to cycle through the screens, to return to the list and choose another item, or to print the information. Chapter 2.6 Diagnostic Error Codes Diagnostic error codes occur if the system recognizes a problem while running the Compaq Diagnostic program. These error codes help identify possibly defective subassemblies. Tables 2-4 through 2-16 list possible error codes, a description of the error condition, and the action required to resolve the error condition. IMPORTANT: Retest the system after completing each step. If the problem has been resolved, do not proceed with the remaining steps. For assistance in the removal and replacement of a particular subassembly, see Chapter 5, Removal and Replacement Procedures. Table 2-4. Processor Test Error Codes =========================================================================== Error Code Description Recommended Action =========================================================================== 101 - xx CPU test failed Replace the processor board and retest. --------------------------------------------------------------------------- 102 - xx Coprocessor or 1. Run the Configuration and Weitek Error Diagnostics Utilities. 2. Replace the processor board and retest. --------------------------------------------------------------------------- 103 - xx DMA page registers Replace the system board and retest. test failed 104 - xx Interrupt controller master test failed 105 - xx Port 61 error 106 - xx Keyboard controller self-test failed 107 - xx CMOS RAM test failed 108 - xx CMOS interrupt test failed 109 - xx CMOS clock test failed
110 - xx Programmable timer load data test failed 113 - xx Protected mode test failed --------------------------------------------------------------------------- 114 - 01 Speaker test failed 1. Check system configuration. 2. Verify cable connections to speaker. 3. Replace the system board and retest. =========================================================================== Table 2-5. Memory Test Error Codes =========================================================================== Error Code Description Recommended Action =========================================================================== 200 - xx Memory machine ID The following steps apply to error test failed codes 200 - xx and 202 - xx: 202 - xx Memory system ROM 1. Flash the system ROM and retest. checksum failed 2. Replace the system board and retest. --------------------------------------------------------------------------- 203 - xx Write/Read test The following steps apply to error failed codes 203 - xx through 215 - xx: 204 - xx Address test failed 1. Remove the memory module and retest. 2. Install a new memory module and 211 - xx Random pattern test retest. failed 214 - xx Noise test failed 215 - xx Random address test failed =========================================================================== Table 2-6. Keyboard Test Error Codes =========================================================================== Error Code Description Recommended Action =========================================================================== 300 - xx Failed ID Test The following steps apply to error codes 300 - xx through 304 - xx: 301 - xx Failed Self-test/ 1. Check the keyboard connection. If Interface Test disconnected, turn off the computer and connect the keyboard. 2. Replace the keyboard and retest. 302 - xx Failed Individual 3. Replace the system board and retest. Key Test 304 - xx Failed Keyboard Repeat Test =========================================================================== Table 2-7. Parallel Printer Test Error Codes =========================================================================== Error Code Description Recommended Action =========================================================================== 401 - xx Printer failed or The following steps apply to error
not connected codes 401 - xx through 403 - xx: 402 - xx Failed Port Test 1. Connect the printer. 2. Check power to the printer. 403 - xx Printer pattern test 3. Install the loopback connector and failed retest. 4. Check port and IRQ configuration. 5. Replace the system board and retest. =========================================================================== Table 2-8. Diskette Drive Test =========================================================================== Error Code Description Recommended Action =========================================================================== 600 - xx Diskette ID drive The following steps apply to error types test failed codes 600 - xx through 698 - xx: 601 - xx Diskette format 1. Replace the diskette media and failed retest. 2. Check and/or replace the diskette 602 - xx Diskette read test power and signal cables and retest. failed 3. Replace the diskette drive and retest. 603 - xx Diskette write, 4. Replace the system board and read, compare test retest. failed 604 - xx Diskette random read test failed 605 - xx Diskette ID media failed 606 - xx Diskette speed test failed 609 - xx Diskette reset controller test failed 610 - xx Diskette change line test failed 697 - xx Diskette type error 698 - xx Diskette drive speed not within limits --------------------------------------------------------------------------- 699 - xx Diskette drive/media 1. Replace media. ID error 2. Run the Configuration and Diagnostics Utilities. =========================================================================== Table 2-9. Serial Test Error Codes =========================================================================== Error Code Description Recommended Action =========================================================================== 1101 - xx Serial port test 1. Check port configuration failed 2. Replace the system board and retest. ===========================================================================
Table 2-10. Hard Drive Test Error Codes =========================================================================== Error Code Description Recommended Action =========================================================================== 1701 - xx Hard drive format The following steps apply to error test failed codes 1701 - xx through 1736 - xx: 1702 - xx Hard drive read test 1. Run the Configuration and failed Diagnostics Utilities and verify drive type. 2. Verify that all secondary drives 1703 - xx Hard drive write/ have secondary drive capability read/compare test (see Appendix C). failed 3. Replace the hard drive and retest. 4. Replace the system board and retest. 1704 - xx Hard drive random seek test failed 1705 - xx Hard drive controller test failed 1706 - xx Hard drive ready test failed 1707 - xx Hard drive recalibration test failed 1708 - xx Hard drive format bad track test failed 1709 - xx Hard drive reset controller test failed 1710 - xx Hard drive park head test failed 1715 - xx Hard drive head select test failed 1716 - xx Hard drive conditional format test failed 1717 - xx Hard drive ECC * test failed 1719 - xx Hard drive power mode test failed 1724 - xx Network preparation test failed 1736 - xx Drive monitoring test failed ---------------------------------------------------------------------------
* ECC = Error Correction Code =========================================================================== Table 2-11. Video Test Error Codes =========================================================================== Error Code Description Recommended Action =========================================================================== 501 - xx Video controller The following apply to error codes test failed 501 - xx through 516 - xx: 502 - xx Video memory test 1. Disconnect external monitor and test failed with internal LCD display. 2. Check display jumpers on the 503 - xx Video attribute test processor board (see Chapter 5) failed 3. Replace the display assembly and retest. 504 - xx Video character set 4. Replace the system board and retest. test failed 505 - xx Video 80 x 25 mode9x14 character cell test failed 506 - xx Video 80 x 25 mode 8 x 8 character cell test failed 507 - xx Video 40 x 25 mode test failed 508 - xx Video 320 x 200 mode color set 0 test failed 509 - xx Video 320 x 200 mode color set 1 test failed 510 - xx Video 640 x 200 mode test failed 511 - xx Video screen memory page test failed 512 - xx Video gray scale test failed 514 - xx Video white screen test failed 516 - xx Video noise pattern test failed --------------------------------------------------------------------------- Error Code Description Recommended Action --------------------------------------------------------------------------- 2402 - xx Video memory test The following steps apply to error failed codes 2402 - xx through 2456 - xx: 2403 - xx Video attribute test 1. Run the Configuration and
failed Diagnostics Utilities. 2. Replace the display assembly and 2404 - xx Video character set retest. test failed 3. Replace the system board and retest. 2405 - xx Video 80 x 25 mode 9 x 14 character cell test failed 2406 - xx Video 80 x 25 mode 8 x 8 character cell test failed 2408 - xx Video 320 x 200 mode color set 0 test failed 2409 - xx Video 320 x 200 mode color set 1 test failed 2410 - xx Video 640 x 200 mode test failed 2411 - xx Video screen memory page test failed 2412 - xx Video gray scale test failed 2414 - xx Video white screen test failed 2416 - xx Video noise pattern test failed 2418 - xx ECG/VGC memory test failed --------------------------------------------------------------------------- Error Code Description Recommended Action --------------------------------------------------------------------------- 2419 - xx ECG/VGC ROM checksum The following steps apply to error test failed codes 2402 - xx through 2456 - xx: 2421 - xx ECG/VGC 640 x 200 1. Run the Configuration and graphics mode test Diagnostics Utilities. failed 2. Disconnect external monitor and test with internal LCD display. 2422 - xx ECG/VGC 640 x 350 3. Check display jumpers on the 16 color set test processor board (see Chapter 5.) failed 4. Replace the display assembly and retest. 2423 - xx ECG/VGC 640 x 350 5. Replace the system board and retest. 64 color set test failed 2424 - xx ECG/VGC monochrome text mode test
failed 2425 - xx ECG/VGC monochrome graphics mode test failed 2431 - xx 640 x 480 graphics test failure 2432 - xx 320 x 200 graphics (256 color mode) test failure 2448 - xx Advanced VGA Controller test failed 2451 - xx 132-column Advanced VGA test failed 2456 - xx Advanced VGA 256 Color test failed --------------------------------------------------------------------------- 2458 - xx Advanced VGA BitBLT Replace the system board and retest. test 2468 - xx Advanced VGA DAC test 2477 - xx Advanced VGA data path test 2478 - xx Advanced VGA BitBLT test 2480 - xx Advanced VGA Linedraw test =========================================================================== Table 2-12. Audio Test Error Codes =========================================================================== Error Code Description Recommended Action =========================================================================== 3206 - xx Audio System Replace the system board and retest. Internal Error =========================================================================== Table 2-13. Pointing Device Interface Test Error Codes =========================================================================== Error Code Description Recommended Action =========================================================================== 8601 - xx Mouse test failed The following steps apply to 8601 - xx and 8602 - xx: 8602 - xx Interface test failed 1. Replace the EasyPoint II controller board and retest. 2. Replace the system board and retest. =========================================================================== Table 2-14. CD-ROM Test Error Codes
=========================================================================== Error Code Description Recommended Action =========================================================================== 3301 - xx CD-ROM drive read The following steps apply to error test failed codes 3301 - xx through 3305 - xx and 6600 - xx through 6623 - xx: 3305 - xx CD-ROM drive seek 1. Replace the CD and retest. test failed 2. Verify that the speakers are connected. 6600 - xx ID test failed 3. Verify that drivers are loaded and properly installed. 6605 - xx Read test failed 4. Replace the CD-ROM drive and retest. 6608 - xx Controller test 5. Replace the system board and failed retest. 6623 - xx Random read test failed =========================================================================== Chapter 2.7 Troubleshooting Without Diagnostics This section provides information about how to identify and correct some common hardware, memory, and software problems. It also explains several types of common messages that may be displayed on the screen. The following pages contain troubleshooting information on: o Audio o Memory o Battery/battery gauge o MultiBay ISA Expansion Base o CD-ROM drive o PC Card o Diskette/diskette drive o Pointing device o Hard drive o Power o Hardware installation o Printer o Infrared connection o Screen (LCD and CRT) o Keyboard/numeric keypad