Page 911
8.3Copy Model Line (Block Programming, Line)Description: Program some or all line ports to have the same programming as a model line port.Programming: 1. Press CONTROL T for main menu. 2. From the main menu, select lines and press ENTER. 3. From the lines menu, select model line and press ENTER. 4. Type line port number (l-240) or name of model line to be copied and press ENTER. 5. Type line port numbers of lines to match model and press ENTER. (Type line port numbers as n,n,nn or n-nn. ) 6. Press ESCAPE...
Page 912
/M/66-123DXP Plus Programming Instructions 8.4Dire& Inward Dialing (DID) Support The DID line board allows incoming CO calls to reach internal DXP Ph intercom extensions by direct dialing. No attendant assistance is necessary. Since DID lines are incoming only, their direct appearance is limited to attendant stations where status indication may be useful. DID operation requires a group of published directory numbers (400 maximum) provided by the telephone company central office (CO). These directory...
Page 913
8.4. IDirect In ward Dialing Line ExamplesExample 1: Jenny’s Bakery has the following CO numbering blocks: 555-3600 to 555-3619, 555-4520 to 555-4539, 555-1200 to 555-1399. It will receive the 36nn and 45nn calls through CO lines l-5 and the lnnn calls through CO lines 6-8. The system requires two DID blocks for use: block one for CO lines l-5, and block two for CO lines 6-8. The numbers in DID block one have two unique digits and the numbers in DID block two have three unique digits. Assume that DID...
Page 914
8.4.2DID Options DID/DNIS Block Name Description: Choose a T-character name to associate with each DID/DNIS block.Programming: Refer to Section 8.43.DID Control SignallingDescription:Decide upon which address supervision signalling protocol that you will use. This decision will depend upon the type of supervision that is compatible with the CO requirements. Immediate Start: Use this protocol for rotary (pulse dial) lines. With this protocol, the CO will not expect address supervision signalling and may...
Page 915
Expected CO DigitsDescription:Obtain a block of numbers for use from the CO.The DXP Plus supports a maximum of 400 numbers (for example, 555-1000 through 555-1399).You can have a maximum of four DID blocks with each DID block using its own name, signalling protocol, digit addressing method and number of digits needed to avoid numbering conflicts. As a default, the system assigns all DID lines to block one. A DID block represents a group of lines that the system will use to receive calls for one or more...
Page 916
lM166-123DXP Pius Programming hsfruefions 8.4.3DIDlDNlS ProgrammingProgramming: 1. 2. 3. 4. 5. 6. Press CONTROL T for main menu From the main menu, type the selection for lines and press ENTER. From the lines menu, type the selection for DID/DNIS block programming and press ENTER. From the DID/DNIS block prompt line, type the DID/DNIS block number and press ENTER. From the DID/DNIS block programming menu, select options, and press ENTER From the options menu, set the parameters for the DID/DNIS block...
Page 917
8.4.4DID/DNIS Translation TablesDescription: When you initialize a translation table, you must first enter the string of CO digits that you obtain from the telephone company. Then you must enter the intercom number that you want to match with the first CO digit sequence in the string. With this, the system automatically matches the remainder of the CO digit string to consecutive intercom numbers beginning with the one that you entered. You can edit the translation table by selecting the item number for...
Page 918
IM166-123BXP PIUS Programming InsPfi~e~iof9s DID Translation Tables ProgrammingProgramming: 1~Press CONTROL T for main menu. 2.From the main menu, type the selection for lines and press ENTER. 3.From the lines menu, type the selection for DID/DNIS block programming and press ENTER. 4.From the DID/DNIS block prompt line, type the DID block number and press ENTER. 5.From the DID/DNIS block programming menu, select initialize translation table, and press ENTER, NOTE: Ifyou choose the initialize translation...
Page 919
8.5Ground Start Line Support Description:The multipurpose line board provides system interface for loop start lines, ground start lines, and E and M tie lines. These are typically the three different line types that the central office (CO) makes available for connection to the public switched network. With the ground start line type, the DXP Plus momentarily grounds the ring lead to signal the CO to establish a communications link for an outgoing call. When the CO detects this, it acknowledges by...
Page 920
lMR%G123DXP PIws Programming hsfrwcfions 8.5. IGround Start Line Support ProgrammingProgramming: 1 D 2. 3. 4. 5. 6. 7. 8. 9. Press CONTROL T for main menu. From the main menu, select lines and press ENTER. From the lines menu, select line programming and press ENTER. Type line port number l-240 or previously assigned name and press ENTER. The system displays page 1 of the line programming menu. From line programming menu, type item number for line type and press ENTER. Press SPACE bar to toggle line...