Home > Comdial > Communications System > Comdial Dxp Plus Instructions Manual

Comdial Dxp Plus Instructions Manual

Here you can view all the pages of manual Comdial Dxp Plus Instructions Manual. The Comdial manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 911

8.3Copy Model Line (Block Programming, Line)Description:
Program some or all line ports to have the same programming as a model line port.Programming:
1. Press CONTROL T for main menu.
2. From the main menu, select lines and press ENTER.
3. From the lines menu, select model line and press ENTER.
4. Type line port number (l-240) or name of model line to be copied
and press ENTER.
5. Type line port numbers of lines to match model and press ENTER.
(Type line port numbers as n,n,nn or n-nn. )
6. Press ESCAPE...

Page 912

/M/66-123DXP Plus Programming Instructions
8.4Dire& Inward Dialing (DID) Support
The DID line board allows incoming CO calls to reach internal DXP Ph intercom extensions by direct dialing.
No attendant assistance is necessary. Since DID lines are incoming only, their direct appearance is limited to
attendant stations where status indication may be useful. DID operation requires a group of published directory
numbers (400 maximum) provided by the telephone company central office (CO). These directory...

Page 913

8.4. IDirect In ward Dialing Line ExamplesExample 1:
Jenny’s Bakery has the following CO numbering blocks:
555-3600 to 555-3619,
555-4520 to 555-4539,
555-1200 to 555-1399.
It will receive the 36nn and 45nn calls through CO lines l-5 and the lnnn calls through CO lines 6-8. The system
requires two DID blocks for use: block one for CO lines l-5, and block two for CO lines 6-8. The numbers in
DID block one have two unique digits and the numbers in DID block two have three unique digits. Assume that
DID...

Page 914

8.4.2DID Options
DID/DNIS Block Name
Description:
Choose a T-character name to associate with each DID/DNIS block.Programming:
Refer to Section 8.43.DID Control 
SignallingDescription:Decide upon which address supervision signalling protocol that you will use. This decision will
depend upon the type of supervision that is compatible with the CO requirements.
Immediate Start: Use this protocol for rotary (pulse dial) lines. With this protocol, the CO will
not expect address supervision signalling and may...

Page 915

Expected CO DigitsDescription:Obtain a block of numbers for use from the CO.The DXP Plus supports a maximum of 400
numbers (for example, 555-1000 through 555-1399).You can have a maximum of four DID
blocks with each DID block using its own name, signalling protocol, digit addressing method
and number of digits needed to avoid numbering conflicts. As a default, the system assigns all
DID lines to block one. A DID block represents a group of lines that the system will use to
receive calls for one or more...

Page 916

lM166-123DXP Pius Programming hsfruefions
8.4.3DIDlDNlS ProgrammingProgramming: 1.
2.
3.
4.
5.
6.
Press CONTROL T for main menu
From the main menu, type the selection for lines and press ENTER.
From the lines menu, type the selection for 
DID/DNIS block programming
and press ENTER.
From the 
DID/DNIS block prompt line, type the DID/DNIS block number
and press ENTER.
From the 
DID/DNIS block programming menu, select options, and press ENTER
From the options menu, set the parameters for the 
DID/DNIS block...

Page 917

8.4.4DID/DNIS Translation TablesDescription:
When you initialize a translation table, you must first enter the string of CO digits that you
obtain from the telephone company. Then you must enter the intercom number that you want to
match with the first CO digit sequence in the string. With this, the system automatically
matches the remainder of the CO digit string to consecutive intercom numbers beginning with
the one that you entered. You can edit the translation table by selecting the item number for...

Page 918

IM166-123BXP PIUS Programming InsPfi~e~iof9s
DID Translation Tables ProgrammingProgramming:
1~Press CONTROL T for main menu.
2.From the main menu, type the selection for lines and press ENTER.
3.From the lines menu, type the selection for DID/DNIS block programming
and press ENTER.
4.From the DID/DNIS block prompt line, type the DID block number and press ENTER.
5.From the DID/DNIS block programming menu, select initialize translation table,
and press ENTER,
NOTE: Ifyou choose the initialize translation...

Page 919

8.5Ground Start Line Support
Description:The multipurpose line board provides system interface for loop start lines, ground start lines,
and E and M tie lines. These are typically the three different line types that the central office
(CO) makes available for connection to the public switched network. With the ground start line
type, the DXP Plus momentarily grounds the ring lead to signal the CO to establish a
communications link for an outgoing call. When the CO detects this, it acknowledges by...

Page 920

lMR%G123DXP PIws Programming hsfrwcfions
8.5. IGround Start Line Support ProgrammingProgramming: 
1 D
2.
3.
4.
5.
6.
7.
8.
9.
Press CONTROL T for main menu.
From the main menu, select lines and press ENTER.
From the lines menu, select line programming and press ENTER.
Type line port number l-240 or previously assigned name and press ENTER.
The system displays page 1 of the line programming menu.
From line programming menu, type item number for line type and press ENTER.
Press SPACE bar to toggle line...
Start reading Comdial Dxp Plus Instructions Manual

Related Manuals for Comdial Dxp Plus Instructions Manual

All Comdial manuals