Understanding The System Components
The Telephone Switching System
QuickQis an add-on application, designed specifically
for Comdial DXP and DXPPlusdigital
communications systems. The DXP or DXPPlus
equipment performs the telephone call switching
functions
.
The Digital Voice Announcer
TheQuickQDigital Voice Announcer (DVA) is a
stand alone voice processing system designed to
directly interface with the DXP’s station ports. It
provides voice announcements, recording and
playback under the control of the...

Page 372

Figure 1-1. Overviewing The QuickQ System
CAJS031A
QuickQ
Digital
Voice
Announcer
DXP
Digital
Communications
System
OO
Print
Scroll
Pause
Screen
LockSysRq
BreakNum
Lock/
*-
InsDelEnter78
9
4
56
123+
0.HomePgUp
EndPgDn
Esc                       F1F2 F3 F4 F5         F6 F7 F8
F9 F10        F11 F12
Tab
Cap  Lock
Shift
CtrlAltBack Space Insert Home PgUp
Delete            EndPgDnQWE R T Y           U I
OPASDFGHJKLZ X C V B N           MEnter
Shift
Alt Ctrl~!@
#$
%^&
*(                     )_
+` 1 2 3 4 5...

Page 373

Section 2
Installing The QuickQ System
This section provides the basic hardware installation requirements for theQuickQDigital Voice Announcer
(DVA).
Reviewing The Installation Check List
Review this list ofQuickQSystem components, suggested additional supplies, and required tools and hardware.
QuickQ Package Contents
TheQuickQpackages (product codes ACDXPKA and
ACDXPKB) include the following items:
·Central Call Processor equipped as follows:
—DOS-based personal computer with DOS
operating system and 2...

Page 374

Voice Card Package Contents
The DVA voice cards (product code ACDXP-VCC-4)
that you install in the DVA are also separately
available.
Additional Materials Required
You will need to supply the following items:
25-pair cable and 6-wire cable for house wiring,
66-type station connector block,
four or eight foot section of 3/4–inch thick plywood
backboard, four #8 x 3/4–inch wood screws,
AC power surge protector (recommended).
Tools And Hardware Required
·Fasteners—wood screws, toggle bolts, or -wall...

Page 375

Mounting The Equipment
Typically, you should mount theQuickQDVA cabinet
near the DXP installation; however, you can locate the
DVA cabinet at a maximum distance of 1000 feet
from the DXP if you use #24 twisted-pair wiring. You
must locate the Central Call Processor (personal
computer) within 500 feet of the DXP and DVA
cabinets. If you exceed this distance, you must install
limited distance modems at either end of your cable
run.
1. Unpack and carefully inspect all equipment for
shipping damage. Notify...

Page 376

Section 3
Wiring The QuickQ System
TheQuickQDigital Voice Announcer (DVA) includes one to four voice channel cards with each card providing four
voice ports. Before wiring, insure that there are sufficient DXP digital station ports available at a station connector
block to interface with the available DVA voice ports (maximum of 16 required).
CAUTION
You must connect all four voice ports from each voice channel card to station ports
from the same DXP station board or the QuickQ system will not function...

Page 377

Connecting The Personal Computer To The DVA
1.Locate the kit-supplied modular jack that is
labeled LINK ASSEMBLY FROM PC TO
66-BLOCK, and mount it within seven feet of the
computer location. .
2.Select the kit-supplied modular to 9-pin EIA
adapter, connect it to the computer’s COM1 serial
data port, and secure the adapter with the screws
provided.
3.Use 6-wire cable to connect the modular jack that
you installed in step 1 with the QuickQ-supplied
66-type connector block.
4.Use a kit-supplied line cord to...

Page 378

QUICK001
COM1 Serial Data Port
9-Pin D Connector
Rear View of
Typical Personal
Computer (PC)
Kit-Supplied
Modular
to 9-pin
EIA adapter
QuickQ-
Supplied And
Punched-Down
25-Pair Cable
6-Wire Cable
House Wiring
Kit-Supplied
3-Pair Line Cord
64
53
2
1
Front View of Jack
Kit-Supplied Type 625A-6
Modular Jack (LINK ASSEMBLY
FROM PC TO 66-BLOCK)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
501
2
3
4
5
6
7
8
9
10
11
12...

Page 379

Connecting The Personal Computer To The DXP or DXP Plus
1. Locate a kit-supplied modular jack labeled LINK
ASSEMBLY FROM DXP TO 66-BLOCK FOR
PC, and mount it within seven feet of the DXP
cabinet.
2. Locate a kit-supplied modular jack labeled LINK
ASSEMBLY FROM PC TO 66-BLOCK FOR
OAI, and mount it within seven feet of the
personal computer.
3. Use 6-wire cable to connect the modular jacks that
you installed in steps 1 and 2 to the
QuickQ-supplied 66-type connector block per the
following house wiring...

Page 380

DXP021C
*Customer-supplied
9-pin to 25-pin
adapter (optional)
Serial Data
Port 9-pin
D Connector
Serial Data Port
25-pin D Connector
Rear View of
Typical Personal
Computer (PC)
Kit-Supplied
Modular
to 25-pin
EIA adapter
RS-232 Ports (Server End)
DSR (Data Set Ready) and DTR (Data Terminal Ready) are connected kit-supplied inside modular to 25-pin adapter.
RS-232 1
RS-232 2
1 = RTS
2 = CTS
3 = RD
4 = TD
5 = GND
6 = NC(Request To Send)
(Clear To Send)
(Receive Data)
(Transmit Data)
(Ground)
(No...
Start reading Comdial Dxp Plus Instructions Manual

Related Manuals for Comdial Dxp Plus Instructions Manual

All Comdial manuals