    4.5.4 Fixed slot (slot 1 & 2)
    Where to find?
    Slot 1 & 2 has 5 BNC input terminals for 5 cable input and a DVI plug for DVI input. Slot 1 has also an DVI output for loop through
    to a second projector. Within the installation mode it is possible to setup the input for 5 cable or DVI (PanelLink).
    Which signals can be connected to slot 1 & 2?
    Connector name/
    Input signalRGBHV
    RGBHVRGBHV
    RGBSRGBS-
    RGsBRGsB--
    Composite Video-Video---
    Super Video-Y--C
    Component Video — SSR-YYB-YS-
    Component Video — SOYR-YYsB-Y--
    DVI signals can be connected to the DVI input connector.
    Pin assignment for the DVI connector.
    Pin 1
    TMDS DATA2-Pin 13
    TMDS DATA3+
    Pin 2
    TMDS DATA2+Pin14 +5Power
    Pin 3
    TMDS DATA2/4 ShieldPin 15
    Ground (for +5V)
    Pin 4
    TMDS DATA4-Pin 16 Hot Plug Detect
    Pin 5
    TMDS DATA4+Pin 17
    TMDS DATA0-
    Pin 6
    DDC ClockPin 18
    TMDS DATA0+
    Pin 7
    DDC DataPin 19
    TMDS DATA0/5 Shield
    Pin 8 No connect Pin 20
    TMDS DATA5-
    Pin 9
    TMDS DATA1-Pin 21
    TMDS DATA5+
    Pin 10
    TMDS DATA1+Pin 22
    TMDS Clock Shield
    Pin 11
    TMDS DATA1/3 ShieldPin 23
    TMDS Clock+
    Pin 12
    TMDS DATA3-Pin 24
    TMDS Clock-
    How to select input slot 1 or 2 ?
    1. Key in 1 or 2 on the RCU or the local keypad.
    How to change the input slot setting?
    1. PressADJUSTorENTERkey to start up the Adjustment mode.
    2. Push the cursor key↑or↓to selectInstallation.
    ADJUSTMENT MODE
    Select a path from below :
    RANDOM ACCESS
    INSTALLATION
    SERVICE
    Select with↑or↓
    then 
     to return
    Menu 4-4
    R5976654 SLM R12+ 27/01/200537 
    						
    							4. Connections
    3. PressENTER.
    4. Press the cursor key↑or↓to selectInput Slots.
    INSTALLATION
    INPUT SLOTS
    800 PERIPHERAL
    SOURCE SWITCHING
    NO SIGNAL
    CONTRAST ENHANCEMENT
    CONVERGENCE
    CONFIGURATION
    LENS
    QUICK ACCESS KEYS
    OSD
    INTERNAL PATTERNS
    Select with↑or↓
    then 
     to return
    Menu 4-5
    5. PressENTER.
    The internal system will scan the inputs and displays the result in theInput Slotsmenu.
    6. Push the cursor key↑or↓to select the first or second slot.
    INPUT SLOTS
    Slot Module type [config]
    1. RGB-SS [CV]
    2. RGB-SOG
    3. SDI
    4. SDI
    ______________
    1. DVI OUTPUT [DVI input]
    Select with↑or↓
    then 
     to return
    Menu 4-6
    Possible indications on the input slot menu.
    For the input side:
    • RGS-SS [CV or HS&VS] = RGB analog signals, separate sync is composite sync or horizontal and vertical sync.
    • RGB-SS [CV] = RGB analog signals, separate sync is composite video.
    • RGB-SOG [SOG or 3LSOG] = RGB analog signals, sync on green is composite sync or composite tri-level sync.
    • COMPONENT VIDEO - SS [SS or 3LSS] = separate sync is composite sync or composite tri-level sync.
    • COMPONENT VIDEO - SOY [SOY or 3LSOY] = component videowith composite sync on Y or composite tri-level sync on Y.
    •VIDEO
    •S-VIDEO
    •DVI
    When changing from an analog signal on the 5 cable module to the PanelLink input the indication led on the front panel of the module
    will switch from the 5 cable input to the DVI (PanelLink) input also.
    For the output on fixed slot 1:
    • DVI input : DVI in signal is looped through to the DVI out connector as it is.
    • Active image : active image signal, what ever the input is, is available in DVI on the DVI output signal (processing is incorporated
    in the signal). Set the minimum delay inInstallation>Advanced processingto OFF.
    • DVI resync : DVI in signal is resyncronized with a stable clock and put on the DVI out connector
    When using an RCVDS 05 with a 5 cable output module, connect these 5 cables to this fixed 5-input slot (slot
    1) of the projector. All sources of the RCVDS can now be accepted by the projector.
    4.5.5 Serial Digital Input (slot 3 & 4)
    What can be connected to this input?
    This input is full compatibility with digital Betacam, or other digital video sources. This avoids the need for analog video processing
    anywhere in the video production chain and guarantees the ultimate image quality.
    An active loop-through of the SDI input signal is provided for monitoring or for double and or triple stacking applications.
    38
    R5976654 SLM R12+ 27/01/2005 
    						
    							4. Connections
    How to connect ?
    1. Connect the output of your SDI source to the input BNC of the SDI input.
    OUT IN OnR9840450
    HD SDI DIGITAL MODULE
    OUT IN On9840110
    SDI DIGITAL INPUT
    COMM PORTTRIGGER OUT
    RS232/422 OUT
    RS232/422 INIR-Receiver Diagnostic Code
    Green Operation
    Red Stand-by
    IR Sync OK
    Hardwired
    remote
    CTRL 1 Hardwired
    remote
    CTRL 2 Two way
    hardwired
    remote
    CTRL 3
    OnOn
    OnOn
    DIGITAL VIDEO SOURCE
    DigitalVideo
    DVI INPUT
    DVI INPUT
    DVI OUTPUT High Bandwidth  5 CABLE INPUT
    High Bandwidth  5 CABLE INPUTRGBH/C V
    RGBH/C V
    Image 4-5Note:The input is always 75Ωterminated.
    2. If loop through is needed, use the OUT to connect to the next device.
    How to select the digital input?
    1. Key in the corresponding slot number on the RCU or the local keypad.
    When a RCVDS05 is connected to the projector, the SDI input is available by keying in 83 or 84 on the RCU.
    4.5.6 HD SDI Digital input (slot 3 & 4)
    What can be connected to this input?
    This input is full compatibility with HD digital sources. This avoids the need for analog video processing anywhere in the video
    production chain and guarantees the ultimate image quality.
    An active loop-through of the HD SDI input signal is provided for monitoring or for double and or triple stacking applications.
    How to connect ?
    1. Connect the output of your HD SDI source to the input BNC of the HD SDI input.
    R5976654 SLM R12+ 27/01/2005
    39 
    						
    							4. Connections
    OUT IN OnR9840450
    HD SDI DIGITAL MODULE
    OUT IN On9840110
    SDI DIGITAL INPUT
    COMM PORTTRIGGER OUT
    RS232/422 OUT
    RS232/422 INIR-Receiver Diagnostic Code
    Green Operation
    Red Stand-by
    IR Sync OK
    Hardwired
    remote
    CTRL 1 Hardwired
    remote
    CTRL 2 Two way
    hardwired
    remote
    CTRL 3
    OnOn
    OnOn
    DIGITAL VIDEO SOURCE
    DigitalVideo
    DVI INPUT
    DVI INPUT
    DVI OUTPUT High Bandwidth  5 CABLE INPUT
    High Bandwidth  5 CABLE INPUTRGBH/C V
    RGBH/C V
    Image 4-6Note:The input is always 75Ωterminated.
    2. If loop through is needed, use the OUT to connect to the next device.
    How to select the digital input?
    1. Key in the corresponding slot number on the RCU or the local keypad.
    When a RCVDS05 is connected to the projector, the SDI input is available by keying in 83 or 84 on the RCU.
    4.5.7 Digital Video Decoder Input
    What can be connected to this input?
    The following source types can be connected:
    •S-Video
    • Component Video
    • Composite Video
    Which signal can be connected to the Digital Video Decoder module?
    Connector name/
    Input signalPbY/VidPrS-Video
    Component VideoB-YYsR-Y-
    Composite Video-Video--
    S-Video---S-Video
    How to connect?
    1. Connect the output of your source to the corresponding inputs on the Digital Video Decoder module.
    40
    R5976654 SLM R12+ 27/01/2005 
    						
    							4. Connections
    OUT IN OnR9840450
    HD SDI DIGITAL MODULE
    PRPB On
    COMM PORTEthernet 
    RS232/422 OUT
    RS232/422 INIR-Receiver Diagnostic Code
    Green Operation
    Red Stand-by
    IR Sync OK
    Hardwired
    remote
    CTRL 1 Hardwired
    remote
    CTRL 2 Two way
    hardwired
    remote
    CTRL 3
    OnOn
    OnOn
    DVI INPUT
    DVI INPUT
    DVI OUTPUT High Bandwidth  5 CABLE INPUT
    High Bandwidth  5 CABLE INPUTRGBH/C V
    RGBH/C V
    DIGITAL VIDEO DECODER
    S-Video 
    Y/Vid
    123Image 4-71 Component video input
    2 Composite Video input
    3 S-Video input
    How to select the digital video decoder input?
    1. Key in the corresponding slot number on the RCU or the local keypad.
    How to change the input slot setting?
    1. PressADJUSTorENTERkey to start up the Adjustment mode.
    2. Push the cursor key↑or↓to selectInstallation.
    ADJUSTMENT MODE
    Select a path from below :
    RANDOM ACCESS
    INSTALLATION
    SERVICE
    Select with↑or↓
    then 
     to return
    Menu 4-7
    3. PressENTER.
    4. Press the cursor key↑or↓to selectInput Slots.
    INSTALLATION
    INPUT SLOTS
    800 PERIPHERAL
    SOURCE SWITCHING
    NO SIGNAL
    CONTRAST ENHANCEMENT
    CONVERGENCE
    CONFIGURATION
    LENS
    QUICK ACCESS KEYS
    OSD
    INTERNAL PATTERNS
    Select with↑or↓
    then 
     to return
    Menu 4-8
    5. PressENTER.
    The internal system will scan the inputs and displays the result in theInput Slotsmenu.
    R5976654 SLM R12+ 27/01/2005
    41 
    						
    							4. Connections
    6. Push the cursor key↑or↓to select the third or fourth slot.
    INPUT SLOTS
    Slot Module type [config]
    1. RGB-SS [CV]
    2. RGB-SOG
    3. SDI
    4. SDI
    ______________
    1. DVI OUTPUT [DVI input]
    Select with↑or↓
    then 
     to return
    Menu 4-9
    7. PressENTERto toggle.
    Possible indications on the input slot menu.
    - VIDEO[VDEO]
    - VIDEO[S-VIDEO]
    - VIDEO[YUV]
    4.6 Communication Connections
    Overview
    • RS232 (RS422) Connection
    • Linked System
    • Communication with peripherals
    • Network connection
    4.6.1 RS232 (RS422) Connection
    Application
    1. Remote control :
    - easy adjustment of projector via an IBM PC (or compatible) or MAC connection.
    - allow storage of multiple projector configurations and set ups.
    - wide range of control possibilities.
    - address range from 0 to 255.
    2. data communications : sending data to the projector or copying the data from the projector to a hard memory device (hard disc,
    floppy, etc.).
    Set up of the Baud Rate for communication with a computer.
    see Baud rate Setting, page 116.
    4.6.2 Linked System
    CAUTION:Always use the Barco COM 800 Splitter, R9827941 (240V) or R9827948 (110V), when using the COM
    800 protocol.
    What can be done?
    In a complex multi-channel setup, projectors can be controlled using the RS232 or COM800 Protocol.
    CLO can be controlled by both protocols, however by using the COM800 port for this adjustment, the RS232 Port can still be used
    for general RS232 commands.
    The following procedure will describe how to connect COM800 LinkedSystem.
    How to connect a COM800 Setup
    Always use the Barco COM 800 Splitter,R9827941(240V) orR9827948(110V), when using the COM 800 protocol.
    1. Use a data cable with at least 9 cores and 2 DB9 female connectors, just cross the pin 2 and pin 3 connection to make a Custom
    Null Modem Cable.
    42
    R5976654 SLM R12+ 27/01/2005 
    						
    							4. Connections
    456789 123
    456789 1
    Pin Number Pin NumberDB9
    Female
    Connector
    DB9
    Female
    Connector23
    Image 4-8
    Make a Custom Null Modem Cable
    2. Use the Custom Null Modem Cable to connect the COM 800 port of the master-projector to the ’To Switcher’ port on the frontside
    of the COM 800 Splitter.
    R5976654 SLM R12+ 27/01/2005
    43 
    						
    							4. Connections
    To next COMM 800 Splitter
    COM 800 Splitter 1 (R9827941)Front
    Slave 1
    TO SWITCHER
    COMM 800 Splitter
    To Slave 2To Slave 3
    Custom Null Modem Cable
    TO IR RECEIVER
    Front
    Slave 4
    To Slave 5To Slave 6
    TO SWITCHER
    COMM 800 SplitterTO IR RECEIVER
    BackTO PROJ.1TO PROJ.2TO PROJ.3TO PROJ.4
    BackTO PROJ.1TO PROJ.2TO PROJ.3TO PROJ.4
    COM 800 Splitter 2
    Two Way
    hardwired
    remoteHardwired
    remote
    Hardwired
    remote
    10(/100)BASE-T RS 232/422 IN RS 232/422 OUT COMM PORT
    Read instructionsbefore
    connecting periphals Sync OK IR Green operational
    Red Stand-byIR-Reciever Diagnostic Code
    CTRL 3CTRL 2
    CTRL 1
    Two Way
    hardwired
    remoteHardwired
    remote
    Hardwired
    remote
    10(/100)BASE-T RS 232/422 IN RS 232/422 OUT COMM PORT
    Read instructionsbefore
    connecting periphals Sync OK IR Green operational
    Red Stand-byIR-Reciever Diagnostic Code
    CTRL 3CTRL 2
    CTRL 1
    Two Way
    hardwired
    remoteHardwired
    remote
    Hardwired
    remote
    10(/100)BASE-T RS 232/422 IN RS 232/422 OUT COMM PORT
    Read instructionsbefore
    connecting periphals Sync OK IR Green operational
    Red Stand-byIR-Reciever Diagnostic Code
    CTRL 3CTRL 2
    CTRL 1
    Image 4-9
    Com 800 Connection
    3. Continue by connecting the slave projectors to the ’To Proj.’connectors on the backside of the COM 800 Splitter (image 4-9).
    4. When dealing with more than 4 slave projectors, the ’To Proj.’ connectors on the backside of the COM 800 Splitter can also be
    used to connect extra COM 800 Splitters (image 4-9).
    44
    R5976654 SLM R12+ 27/01/2005 
    						
    							4. Connections
    4.6.3 Communication with peripherals
    What is possible with an RCVDS05 connected.
    • Up to 20 inputs with the RCVDS 05 and 90 inputs when RCVDS’s are linked via the expansion module.
    • Serial communication with the projector.
    • Remote control buttons on the RCVDS to control theprojector (source selection and analog settings).
    • Theselectedsourcenumberwillbedisplayedona2digitdisplayandtheselectedinput module will be indicated with a LED
    on the rear.
    For more information about the use of the RCVDS05, consult the owner’s manual of the RCVDS05.
    What is possible with an VS05 connected.
    The VS05 can switch up to 5 Composite Video sources, 3 Super Video sources and 1 RGB analog or component video source to
    the projector. In addition, the audio signal proper to the source, can be switched to an audio amplifier. Order number : R9827890
    For more information about the use of the VS05, consult the VS05 owner’s manual.
    Connecting an IR Remote Receiver to the projector.
    This infrared receiver unit makes it possible to control the projector from another room. There is a communication line cable between
    the IR receiver and the projector or the RCVDS. The control information from the RCU can now be sent to the IR Remote Receiver.
    The IR Remote Receiver displays the selected source on a 7-segment display.
    Connecting a Rugged Remote to the projector.
    The Rugged Remote Control allows following functions:
    • Remote mode : sends actions to and reads information from the projector.
    • Lamp read mode : reads information stored in the lamp information module.
    The following types of Rugged Remote Control are available:
    • wireless (order numberR9840171)
    • wired to CTRL3 (order numberR9840170)
    For more information about the use of this remote control, consult the user manual R5976251.
    4.6.4 Network connection
    Only 10 Base-T connection
    What can be done?
    When the optional network connection is installed, the projectorcan be connected to a LAN (local areanetwork) (Ethernet). Once
    installed and connected to the LAN, users arecapable of accessing the projector from any location, inside or outside their company
    network from a standard web browser. The projector acts as web serverand generates a web site with all functions of the projector
    listed. Via an internet explorer 4.0 or higher, or a Netscape communicator, the user can insert the correct IP-address of the projector
    and access the webpages. Once the web site is accessed, it is possible to check and manipulate all the projector settings. Remote
    diagnostics, control and monitoring of the projector can then become a daily and very simple operation. The network connectivity
    permits to detect potential errors and consequently improve the time to servicing.
    R5976654 SLM R12+ 27/01/2005
    45 
    						
    							4. Connections
    OUT IN OnR9840450
    HD SDI DIGITAL MODULE
    OUT IN On9840110
    SDI DIGITAL INPUT
    COMM PORTTRIGGER OUT
    RS232/422 OUT
    RS232/422 INIR-Receiver Diagnostic Code
    Green Operation
    Red Stand-by
    IR Sync OK
    Hardwired
    remote
    CTRL 1 Hardwired
    remote
    CTRL 2 Two way
    hardwired
    remote
    CTRL 3
    OnOn
    OnOn
    DVI INPUT
    DVI INPUT
    DVI OUTPUT High Bandwidth  5 CABLE INPUT
    High Bandwidth  5 CABLE INPUTRGBH/C V
    RGBH/C V
    Ethernet 
    connection
    Image 4-10
    Always use an Ethernet cable with ferrite core to connect the projector to the LAN.
    46R5976654 SLM R12+ 27/01/2005 
    						
    All Barco manuals Comments (0)

    Related Manuals for Barco Slm R12+ Owners Manual