Barco Slm R12+ Owners Manual
Have a look at the manual Barco Slm R12+ Owners Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 183 Barco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
4. Connections 4.5.4 Fixed slot (slot 1 & 2) Where to find? Slot 1 & 2 has 5 BNC input terminals for 5 cable input and a DVI plug for DVI input. Slot 1 has also an DVI output for loop through to a second projector. Within the installation mode it is possible to setup the input for 5 cable or DVI (PanelLink). Which signals can be connected to slot 1 & 2? Connector name/ Input signalRGBHV RGBHVRGBHV RGBSRGBS- RGsBRGsB-- Composite Video-Video--- Super Video-Y--C Component Video — SSR-YYB-YS- Component Video — SOYR-YYsB-Y-- DVI signals can be connected to the DVI input connector. Pin assignment for the DVI connector. Pin 1 TMDS DATA2-Pin 13 TMDS DATA3+ Pin 2 TMDS DATA2+Pin14 +5Power Pin 3 TMDS DATA2/4 ShieldPin 15 Ground (for +5V) Pin 4 TMDS DATA4-Pin 16 Hot Plug Detect Pin 5 TMDS DATA4+Pin 17 TMDS DATA0- Pin 6 DDC ClockPin 18 TMDS DATA0+ Pin 7 DDC DataPin 19 TMDS DATA0/5 Shield Pin 8 No connect Pin 20 TMDS DATA5- Pin 9 TMDS DATA1-Pin 21 TMDS DATA5+ Pin 10 TMDS DATA1+Pin 22 TMDS Clock Shield Pin 11 TMDS DATA1/3 ShieldPin 23 TMDS Clock+ Pin 12 TMDS DATA3-Pin 24 TMDS Clock- How to select input slot 1 or 2 ? 1. Key in 1 or 2 on the RCU or the local keypad. How to change the input slot setting? 1. PressADJUSTorENTERkey to start up the Adjustment mode. 2. Push the cursor key↑or↓to selectInstallation. ADJUSTMENT MODE Select a path from below : RANDOM ACCESS INSTALLATION SERVICE Select with↑or↓ then to return Menu 4-4 R5976654 SLM R12+ 27/01/200537
4. Connections 3. PressENTER. 4. Press the cursor key↑or↓to selectInput Slots. INSTALLATION INPUT SLOTS 800 PERIPHERAL SOURCE SWITCHING NO SIGNAL CONTRAST ENHANCEMENT CONVERGENCE CONFIGURATION LENS QUICK ACCESS KEYS OSD INTERNAL PATTERNS Select with↑or↓ then to return Menu 4-5 5. PressENTER. The internal system will scan the inputs and displays the result in theInput Slotsmenu. 6. Push the cursor key↑or↓to select the first or second slot. INPUT SLOTS Slot Module type [config] 1. RGB-SS [CV] 2. RGB-SOG 3. SDI 4. SDI ______________ 1. DVI OUTPUT [DVI input] Select with↑or↓ then to return Menu 4-6 Possible indications on the input slot menu. For the input side: • RGS-SS [CV or HS&VS] = RGB analog signals, separate sync is composite sync or horizontal and vertical sync. • RGB-SS [CV] = RGB analog signals, separate sync is composite video. • RGB-SOG [SOG or 3LSOG] = RGB analog signals, sync on green is composite sync or composite tri-level sync. • COMPONENT VIDEO - SS [SS or 3LSS] = separate sync is composite sync or composite tri-level sync. • COMPONENT VIDEO - SOY [SOY or 3LSOY] = component videowith composite sync on Y or composite tri-level sync on Y. •VIDEO •S-VIDEO •DVI When changing from an analog signal on the 5 cable module to the PanelLink input the indication led on the front panel of the module will switch from the 5 cable input to the DVI (PanelLink) input also. For the output on fixed slot 1: • DVI input : DVI in signal is looped through to the DVI out connector as it is. • Active image : active image signal, what ever the input is, is available in DVI on the DVI output signal (processing is incorporated in the signal). Set the minimum delay inInstallation>Advanced processingto OFF. • DVI resync : DVI in signal is resyncronized with a stable clock and put on the DVI out connector When using an RCVDS 05 with a 5 cable output module, connect these 5 cables to this fixed 5-input slot (slot 1) of the projector. All sources of the RCVDS can now be accepted by the projector. 4.5.5 Serial Digital Input (slot 3 & 4) What can be connected to this input? This input is full compatibility with digital Betacam, or other digital video sources. This avoids the need for analog video processing anywhere in the video production chain and guarantees the ultimate image quality. An active loop-through of the SDI input signal is provided for monitoring or for double and or triple stacking applications. 38 R5976654 SLM R12+ 27/01/2005
4. Connections How to connect ? 1. Connect the output of your SDI source to the input BNC of the SDI input. OUT IN OnR9840450 HD SDI DIGITAL MODULE OUT IN On9840110 SDI DIGITAL INPUT COMM PORTTRIGGER OUT RS232/422 OUT RS232/422 INIR-Receiver Diagnostic Code Green Operation Red Stand-by IR Sync OK Hardwired remote CTRL 1 Hardwired remote CTRL 2 Two way hardwired remote CTRL 3 OnOn OnOn DIGITAL VIDEO SOURCE DigitalVideo DVI INPUT DVI INPUT DVI OUTPUT High Bandwidth 5 CABLE INPUT High Bandwidth 5 CABLE INPUTRGBH/C V RGBH/C V Image 4-5Note:The input is always 75Ωterminated. 2. If loop through is needed, use the OUT to connect to the next device. How to select the digital input? 1. Key in the corresponding slot number on the RCU or the local keypad. When a RCVDS05 is connected to the projector, the SDI input is available by keying in 83 or 84 on the RCU. 4.5.6 HD SDI Digital input (slot 3 & 4) What can be connected to this input? This input is full compatibility with HD digital sources. This avoids the need for analog video processing anywhere in the video production chain and guarantees the ultimate image quality. An active loop-through of the HD SDI input signal is provided for monitoring or for double and or triple stacking applications. How to connect ? 1. Connect the output of your HD SDI source to the input BNC of the HD SDI input. R5976654 SLM R12+ 27/01/2005 39
4. Connections OUT IN OnR9840450 HD SDI DIGITAL MODULE OUT IN On9840110 SDI DIGITAL INPUT COMM PORTTRIGGER OUT RS232/422 OUT RS232/422 INIR-Receiver Diagnostic Code Green Operation Red Stand-by IR Sync OK Hardwired remote CTRL 1 Hardwired remote CTRL 2 Two way hardwired remote CTRL 3 OnOn OnOn DIGITAL VIDEO SOURCE DigitalVideo DVI INPUT DVI INPUT DVI OUTPUT High Bandwidth 5 CABLE INPUT High Bandwidth 5 CABLE INPUTRGBH/C V RGBH/C V Image 4-6Note:The input is always 75Ωterminated. 2. If loop through is needed, use the OUT to connect to the next device. How to select the digital input? 1. Key in the corresponding slot number on the RCU or the local keypad. When a RCVDS05 is connected to the projector, the SDI input is available by keying in 83 or 84 on the RCU. 4.5.7 Digital Video Decoder Input What can be connected to this input? The following source types can be connected: •S-Video • Component Video • Composite Video Which signal can be connected to the Digital Video Decoder module? Connector name/ Input signalPbY/VidPrS-Video Component VideoB-YYsR-Y- Composite Video-Video-- S-Video---S-Video How to connect? 1. Connect the output of your source to the corresponding inputs on the Digital Video Decoder module. 40 R5976654 SLM R12+ 27/01/2005
4. Connections OUT IN OnR9840450 HD SDI DIGITAL MODULE PRPB On COMM PORTEthernet RS232/422 OUT RS232/422 INIR-Receiver Diagnostic Code Green Operation Red Stand-by IR Sync OK Hardwired remote CTRL 1 Hardwired remote CTRL 2 Two way hardwired remote CTRL 3 OnOn OnOn DVI INPUT DVI INPUT DVI OUTPUT High Bandwidth 5 CABLE INPUT High Bandwidth 5 CABLE INPUTRGBH/C V RGBH/C V DIGITAL VIDEO DECODER S-Video Y/Vid 123Image 4-71 Component video input 2 Composite Video input 3 S-Video input How to select the digital video decoder input? 1. Key in the corresponding slot number on the RCU or the local keypad. How to change the input slot setting? 1. PressADJUSTorENTERkey to start up the Adjustment mode. 2. Push the cursor key↑or↓to selectInstallation. ADJUSTMENT MODE Select a path from below : RANDOM ACCESS INSTALLATION SERVICE Select with↑or↓ then to return Menu 4-7 3. PressENTER. 4. Press the cursor key↑or↓to selectInput Slots. INSTALLATION INPUT SLOTS 800 PERIPHERAL SOURCE SWITCHING NO SIGNAL CONTRAST ENHANCEMENT CONVERGENCE CONFIGURATION LENS QUICK ACCESS KEYS OSD INTERNAL PATTERNS Select with↑or↓ then to return Menu 4-8 5. PressENTER. The internal system will scan the inputs and displays the result in theInput Slotsmenu. R5976654 SLM R12+ 27/01/2005 41
4. Connections 6. Push the cursor key↑or↓to select the third or fourth slot. INPUT SLOTS Slot Module type [config] 1. RGB-SS [CV] 2. RGB-SOG 3. SDI 4. SDI ______________ 1. DVI OUTPUT [DVI input] Select with↑or↓ then to return Menu 4-9 7. PressENTERto toggle. Possible indications on the input slot menu. - VIDEO[VDEO] - VIDEO[S-VIDEO] - VIDEO[YUV] 4.6 Communication Connections Overview • RS232 (RS422) Connection • Linked System • Communication with peripherals • Network connection 4.6.1 RS232 (RS422) Connection Application 1. Remote control : - easy adjustment of projector via an IBM PC (or compatible) or MAC connection. - allow storage of multiple projector configurations and set ups. - wide range of control possibilities. - address range from 0 to 255. 2. data communications : sending data to the projector or copying the data from the projector to a hard memory device (hard disc, floppy, etc.). Set up of the Baud Rate for communication with a computer. see Baud rate Setting, page 116. 4.6.2 Linked System CAUTION:Always use the Barco COM 800 Splitter, R9827941 (240V) or R9827948 (110V), when using the COM 800 protocol. What can be done? In a complex multi-channel setup, projectors can be controlled using the RS232 or COM800 Protocol. CLO can be controlled by both protocols, however by using the COM800 port for this adjustment, the RS232 Port can still be used for general RS232 commands. The following procedure will describe how to connect COM800 LinkedSystem. How to connect a COM800 Setup Always use the Barco COM 800 Splitter,R9827941(240V) orR9827948(110V), when using the COM 800 protocol. 1. Use a data cable with at least 9 cores and 2 DB9 female connectors, just cross the pin 2 and pin 3 connection to make a Custom Null Modem Cable. 42 R5976654 SLM R12+ 27/01/2005
4. Connections 456789 123 456789 1 Pin Number Pin NumberDB9 Female Connector DB9 Female Connector23 Image 4-8 Make a Custom Null Modem Cable 2. Use the Custom Null Modem Cable to connect the COM 800 port of the master-projector to the ’To Switcher’ port on the frontside of the COM 800 Splitter. R5976654 SLM R12+ 27/01/2005 43
4. Connections To next COMM 800 Splitter COM 800 Splitter 1 (R9827941)Front Slave 1 TO SWITCHER COMM 800 Splitter To Slave 2To Slave 3 Custom Null Modem Cable TO IR RECEIVER Front Slave 4 To Slave 5To Slave 6 TO SWITCHER COMM 800 SplitterTO IR RECEIVER BackTO PROJ.1TO PROJ.2TO PROJ.3TO PROJ.4 BackTO PROJ.1TO PROJ.2TO PROJ.3TO PROJ.4 COM 800 Splitter 2 Two Way hardwired remoteHardwired remote Hardwired remote 10(/100)BASE-T RS 232/422 IN RS 232/422 OUT COMM PORT Read instructionsbefore connecting periphals Sync OK IR Green operational Red Stand-byIR-Reciever Diagnostic Code CTRL 3CTRL 2 CTRL 1 Two Way hardwired remoteHardwired remote Hardwired remote 10(/100)BASE-T RS 232/422 IN RS 232/422 OUT COMM PORT Read instructionsbefore connecting periphals Sync OK IR Green operational Red Stand-byIR-Reciever Diagnostic Code CTRL 3CTRL 2 CTRL 1 Two Way hardwired remoteHardwired remote Hardwired remote 10(/100)BASE-T RS 232/422 IN RS 232/422 OUT COMM PORT Read instructionsbefore connecting periphals Sync OK IR Green operational Red Stand-byIR-Reciever Diagnostic Code CTRL 3CTRL 2 CTRL 1 Image 4-9 Com 800 Connection 3. Continue by connecting the slave projectors to the ’To Proj.’connectors on the backside of the COM 800 Splitter (image 4-9). 4. When dealing with more than 4 slave projectors, the ’To Proj.’ connectors on the backside of the COM 800 Splitter can also be used to connect extra COM 800 Splitters (image 4-9). 44 R5976654 SLM R12+ 27/01/2005
4. Connections 4.6.3 Communication with peripherals What is possible with an RCVDS05 connected. • Up to 20 inputs with the RCVDS 05 and 90 inputs when RCVDS’s are linked via the expansion module. • Serial communication with the projector. • Remote control buttons on the RCVDS to control theprojector (source selection and analog settings). • Theselectedsourcenumberwillbedisplayedona2digitdisplayandtheselectedinput module will be indicated with a LED on the rear. For more information about the use of the RCVDS05, consult the owner’s manual of the RCVDS05. What is possible with an VS05 connected. The VS05 can switch up to 5 Composite Video sources, 3 Super Video sources and 1 RGB analog or component video source to the projector. In addition, the audio signal proper to the source, can be switched to an audio amplifier. Order number : R9827890 For more information about the use of the VS05, consult the VS05 owner’s manual. Connecting an IR Remote Receiver to the projector. This infrared receiver unit makes it possible to control the projector from another room. There is a communication line cable between the IR receiver and the projector or the RCVDS. The control information from the RCU can now be sent to the IR Remote Receiver. The IR Remote Receiver displays the selected source on a 7-segment display. Connecting a Rugged Remote to the projector. The Rugged Remote Control allows following functions: • Remote mode : sends actions to and reads information from the projector. • Lamp read mode : reads information stored in the lamp information module. The following types of Rugged Remote Control are available: • wireless (order numberR9840171) • wired to CTRL3 (order numberR9840170) For more information about the use of this remote control, consult the user manual R5976251. 4.6.4 Network connection Only 10 Base-T connection What can be done? When the optional network connection is installed, the projectorcan be connected to a LAN (local areanetwork) (Ethernet). Once installed and connected to the LAN, users arecapable of accessing the projector from any location, inside or outside their company network from a standard web browser. The projector acts as web serverand generates a web site with all functions of the projector listed. Via an internet explorer 4.0 or higher, or a Netscape communicator, the user can insert the correct IP-address of the projector and access the webpages. Once the web site is accessed, it is possible to check and manipulate all the projector settings. Remote diagnostics, control and monitoring of the projector can then become a daily and very simple operation. The network connectivity permits to detect potential errors and consequently improve the time to servicing. R5976654 SLM R12+ 27/01/2005 45
4. Connections OUT IN OnR9840450 HD SDI DIGITAL MODULE OUT IN On9840110 SDI DIGITAL INPUT COMM PORTTRIGGER OUT RS232/422 OUT RS232/422 INIR-Receiver Diagnostic Code Green Operation Red Stand-by IR Sync OK Hardwired remote CTRL 1 Hardwired remote CTRL 2 Two way hardwired remote CTRL 3 OnOn OnOn DVI INPUT DVI INPUT DVI OUTPUT High Bandwidth 5 CABLE INPUT High Bandwidth 5 CABLE INPUTRGBH/C V RGBH/C V Ethernet connection Image 4-10 Always use an Ethernet cable with ferrite core to connect the projector to the LAN. 46R5976654 SLM R12+ 27/01/2005