    							3. Installation Guidelines
    3.5.1 Access to the Lamp Unit.
    What has to be done
    To access the lamp casing, a side panel has to be removed.
    Necessary tools
    A flatblade screwdriver of 5 mm
    Removingthesidepanel
    1. Turn with a screwdriver the side panel lockscrew (A) a quarter turn counter clockwise.
    A
    Image 3-7
    Unlocking the side cover
    2. Pull the right side of the panel towards you and next to the rightto remove.
    AB
    Image 3-8
    Lamp cover removal
    3.5.2 Installation of the new Lamp Unit.
    What has to be done
    First remove the lock nut oneach spacer screw and next slide the lamp unit into the projector frame.
    Necessary tools
    Flatblade screwdriver of 5mm or Nut driver 8mm
    R5976654 SLM R12+ 27/01/2005
    17 
    						
    							3. Installation Guidelines
    Installing the lamp unit
    1. Remove the lock nut (B) on the 3 spacer screws (A).
    B
    A
    Image 3-9
    2. Line up the lamp unit guides (A) with the guides on the projector base (B) and push the unit into the frame until it fits.
    B
    A
    Image 3-10
    Lamp unit mounting
    3. Secure the position of the lamp unit with the 3 spacer screws.
    18
    R5976654 SLM R12+ 27/01/2005 
    						
    							3. Installation Guidelines
    A
    A
    A
    Image 3-11
    Lamp unit fixation
    3.5.3 Reinstalling the Side Panel
    What has to be done
    After the new lamp unit has been installed, the side panel has to be remounted.
    Necessary tools
    A flatblade screwdriver of 5 mm
    Reinstalling the side panel
    1. Move the cover guides under the back cover and push the front of the cover against the projector frame lining up the cover lock
    screw with the speed nut (A) on the frame.
    Image 3-12
    Mounting the side cover
    Image 3-13
    Closing the side cover
    2. Turn with a screwdriver the side panel lock screw (B) a quarter turn clockwise to lock.
    R5976654 SLM R12+ 27/01/2005
    19 
    						
    							3. Installation Guidelines
    B
    Image 3-14
    Locking side panel
    3.6 Realignment of the lamp in its reflector
    WARNING:As the projector has to be opened, this procedure has to be performed by qualified service tech-
    nician.
    Why
    With higher run times, the light output of the lamp will decrease, which results in a lower light output on the screen. This light output
    decrease can be compensated by readjusting the position of the lamp.
    A suggestion dialog box will be displayed when the projector is restarted after 100 hours and 250 hours. OnceENTERis pressed
    when that box is open, this box will not be displayed again till the next alert point is reached.
    Suggestion
    Lamp runtime is
    105 hours
    It is advisable to
    adjust the Z-axis
    of the lamp to
    obtain maximum
    light output
    (see owners manual)
     to confirm
    Menu 3-1
    The user can now adjust the Z-axis by following the next procedure.
    How to readjust.
    1. On the side of the inputs, turn the captive screw a quarter counter clockwise.
    2. Flip the cover to the left side and take off.
    20
    R5976654 SLM R12+ 27/01/2005 
    						
    							3. Installation Guidelines
    Image 3-15
    Lamp adjustment access
    3. Start up the adjustment mode and selectService.
    ADJUSTMENT MODE
    Select a path from below :
    RANDOM ACCESS
    INSTALLATION
    SERVICE
    Select with↑or↓
    then 
     to return
    Menu 3-2
    4. Select Lamp. The Z-axis value indication (lamp menu in service mode) will be helpful while turning screw B .
    SERVICE
    IDENTIFICATION
    CHANGE PASSWORD
    CHANGE LANGUAGE
    CHANGE PROJ. ADDRESS
    SERIAL COMMUNICATION
    NETWORK
    LAMP
    DIMMING
    MORE...
    Select with↑or↓
    then 
     to return
    Menu 3-3
    LAMP
    Constant Light output [OFF]
    Using [RS port]
    Mode [NORMAL]
    Serial number : R101111
    Article number : R9840xxx
    Run time : 10 hours
    Remaining run time : 490
    hours
    Number of strikes : 10
    Z_AXIS : 100
    Select with↑or↓
    then 
     to return.
    Menu 3-4
    5. Loosen the lock nut A, securing the position of the adjustable screw (B), on the back of the lamp casing (nutdriver 10).
    R5976654 SLM R12+ 27/01/2005
    21 
    						
    							3. Installation Guidelines
    A
    Image 3-16
    Lamp Z-Axis alignment (Former lamp house)
    B
    A
    Image 3-17
    Lamp Z-Axis alignment (Universal lamp house)
    6. Slowly turn the screw B (image 3-16, , image 3-17, using an Allenkeyof3mm,alittleclockwiseuntilthemaximumvalueofthe
    Z-AXIS indication in the lamp menu is reached.
    7. Tighten the lock nut on the adjustable screw to secure its position (nutdriver 10).
    CAUTION:Never turn the other screws ! These are factory aligned.
    22R5976654 SLM R12+ 27/01/2005 
    						
    							3. Installation Guidelines
    3.7 Lenses
    Overview
    • Lenses
    • Lens selection
    • Lens formulas
    • Lens Installation
    • Cleaning the lens
    3.7.1 Lenses
    Available lenses
    TLD(1.6–2.0:1)R9840670
    TLD(2.0–2.8:1)R9840680
    TLD(2.8–5.0:1)R9840690
    TLD(1.2:1)R9840770
    TLD(0.8:1)R9840900
    TLD(5.0–8.0:1)R9840910
    TLD HB(0.8:1)R9842040
    TLD HB(1.6–2.0:1)R9842060
    TLD HB(2.0–2.8:1)R9842080
    TLD HB(2.8–5.0:1)R9842100
    TLD HB(5.0–8.0:1)R9842120
    3.7.2 Lens selection
    How to select ?
    1. Determine the required screen width.
    2. Determine the approximate position of the projector in the projection room with regard to the screen and measure the projector-
    screen distance (PD).
    3. Use the lens formulas to find the best corresponding PD with regard to the measured projector-screen distance for the required
    screen width.
    3.7.3 Lens formulas
    Formulas for the standard TLD HB lenses
    Metric formulas (meter)Inch formulas (inch)
    TLD HB(0.8:1)PD=0.77xSW+0.05PD=0.77SW+1.97
    TLD HB(1.2:1)PD=1.11xSW-0.01PD=1.11xSW-0.39
    TLD HB(1.6–2.0:1)PDmin=1.47xSW-0.09
    PD
    max=1.85xSW-0.13
    PDmin=1.47xSW-3.54
    PD
    max=1.85xSW-5.12
    TLD HB(2.0–2.8:1)PDmin=1.85xSW-0.17
    PD
    max=2.62xSW-0.24
    PDmin=1.85xSW-6.69
    PD
    max=2.62xSW-9.45
    TLD HB(2.8–5.0:1)PDmin=2.58xSW-0.16
    PD
    max=4.71xSW-0.38
    PDmin=2.58xSW-6.30
    PD
    max=4.71xSW-14.96
    TLD HB(5.0–8.0:1)PDmin=4.52xSW-0.01
    PD
    max=7.53xSW-0.29
    PDmin=4.52xSW-0.39
    PD
    max=7.53xSW-11.42
    R5976654 SLM R12+ 27/01/200523 
    						
    							3. Installation Guidelines
    Formulas for TLD lenses
    Metric formulas (meter)Inch formulas (inch)
    TLD(0.8:1)PD=0.77xSW+0.05PD=0.77SW+1.97
    TLD(1.2:1)PD=1.11xSW-0.01PD=1.11xSW-0.39
    TLD(1.6–2.0:1)PDmin=1.47xSW-0.09
    PD
    max=1.85xSW-0.13
    PDmin=1.47xSW-3.54
    PD
    max=1.85xSW-5.12
    TLD(2.0–2.8:1)PDmin=1.85xSW-0.17
    PD
    max=2.62xSW-0.24
    PDmin=1.85xSW-6.69
    PD
    max=2.62xSW-9.45
    TLD(2.8–5.0:1)PDmin=2.58xSW-0.16
    PD
    max=4.71xSW-0.38
    PDmin=2.58xSW-6.30
    PD
    max=4.71xSW-14.96
    TLD(5.0–8.0:1)PDmin=4.52xSW-0.01
    PD
    max=7.53xSW-0.29
    PDmin=4.52xSW-0.39
    PD
    max=7.53xSW-11.42
    3.7.4 Lens Installation
    How to install ?
    Follow the next procedure:
    1. Remove the foam rubber in the opening of the lens holder.
    2. Take the lens assembly out of its packing material and remove the lens caps on both sides.
    3. Move the handle (A) of the lens anchor system to the right.
    Image 3-18
    Lens installation
    4. Push the lens, motors at the top, in the lens block gap horizontally, lining up the motor connector on the lens with the connector
    on the lens block (B), until the lens clicks in the lens anchor system.
    24
    R5976654 SLM R12+ 27/01/2005 
    						
    							3. Installation Guidelines
    Image 3-19
    Mounted Lens
    Caution:On a table mounted projector, hold the projector when pushing the lens into the lens blockto avoid sliding off from
    the table.
    3.7.5 Cleaning the lens
    To minimize the possibility of damaging the optical coating or scratching exposed lens surface, we have de-
    veloped recommendations for cleaning the lens. FIRST, we recommend you try to remove any material from
    the lens by blowing it off with clean, dry deionized air. DO NOT use any liquid to clean the lenses.
    Necessary tools
    To r a y s e eTMcloth (delivered together with the lens kit). Order number : R379058.
    Howtocleanthelens?
    Proceed as follow :
    1. Always wipe lenses with a CLEAN Toraysee
    TMcloth.
    2. Always wipe lenses in a single direction.
    Warning:Do not wipe back and forwards across the lens surface as thistends to grind dirt into the coating.
    3. Do not leave cleaning cloth in either an open room or lab coat pocket, as doing so can contaminate the cloth.
    4. If smears occur when cleaning lenses, replace the cloth. Smears are the first indication of a dirty cloth.
    WARNING:Do not use fabric softener when washing the cleaning cloth or softener sheets when drying the
    cloth.
    Do not use liquid cleaners on the cloth as doing so will contaminate the cloth.
    CAUTION:Other lenses can also be cleaned safely with this TorayseeTMcloth.
    3.8 Battery Installation in the RCU
    How is the battery delivered ?
    The battery for the RCU is not yet installed on delivery, to save the battery life time, and is placed in the upper compartment (B)
    inside the RCU (image 3-20).
    Howtoplugin!
    1. Press the battery cover (A) lock (1) inwards and simultaneously lift up the cover (2) for removal.
    R5976654 SLM R12+ 27/01/2005
    25 
    						
    							3. Installation Guidelines
    1 2
    A
    B
    Image 3-20
    Battery cover removal
    2. Plug in the battery (9 V battery - type E-block or equivalent) onto the battery contact plate (A).
    A
    B
    Image 3-21
    Battery connection
    3. Place the battery into the lower compartment (B) (image 3-21).
    4. Insert the pins of the battery cover (A) into the slots on the bottom of battery back cover and close the cover by pushing downwards
    (B) until it clicks.
    AB
    Image 3-22
    Battery cover mount
    5. A card, containing a button preset overview, can be inserted behind the plastic windowpane on the battery cover.
    26
    R5976654 SLM R12+ 27/01/2005 
    						
    All Barco manuals Comments (0)