7. Random Access Adjustment Mode
4. Adjust the contrast to a maximum value until the green noise becomes visible in the white areas and return one step.
5. Adjust with the cursor keys↑or↓or←or→until the red respectively blue noise becomes visible in the white areas and return
one step.
7.3.6.2 Input Balance for YUV signals
Steps to be taken for YUV
1. Is the input balance menu already activated ?
If yes, go to step 4
If no, go to step 2
2. Push the cursor key↑or↓to highlightInput Balance.
PICTURE TUNING...

Page 82

7. Random Access Adjustment Mode
7.3.6.3 Returning to the factory defaults
How to return to the factory defaults
1. Push the cursor key↑or↓to highlightDefault.
INPUT BALANCE
BLACK BALANCE
WHITE BALANCE
DEFAULT
Select with↑or↓
then 
 to return
Adjust
red with↑or↓
blue with←or→
Menu 7-38
2. PressENTERto select.
The default settings will be loaded.
7.3.6.4 Black balance for digital source
How to adjust
Black balance for digital sources such as SDI, HD-SDI and DVI can be adjusted within the ScenergiX menu....

Page 83

7. Random Access Adjustment Mode
7.4.2 Geometry start up
Start up
1. Push the cursor key↑or↓to highlightGeometry.
ADJUSTMENT MODE
Select a path from below :
RANDOM ACCESS
INSTALLATION
SERVICE
Select with↑or↓
then 
 to return
Menu 7-39
2. PressENTERto select.
The geometry menu will be displayed.
GEOMETRY
SHIFT
SIZE
SIDE KEYSTONE
BLANKING
ASPECT RATIO [4:3]
OPTIONS
Select with↑or↓
then 
 to return
Menu 7-40
7.4.3 Shift
What can be done ?
The image can be shifted in a horizontal or vertical direction.
Image...

Page 84

7. Random Access Adjustment Mode
How to shift the image ?
1. Push the cursor key↑or↓to highlightShift.
GEOMETRY
SHIFT
SIZE
SIDE KEYSTONE
BLANKING
ASPECT RATIO [4:3]
OPTIONS
Select with↑or↓
then 
 to return
Menu 7-41
2. PressENTERto select.
3. Push the cursor key↑or↓to shift the image in a vertical direction.
Push the cursor key←or→to shift the image in a horizontal direction.
Note:The default value for the shift is 0.
Shifting in a vertical direction : when the shift value is positive, the image is...

Page 85

7. Random Access Adjustment Mode
B Vertical size adjustment
Size adjustment
1. Push the cursor key↑or↓to highlightSize.
GEOMETRY
SHIFT
SIZE
SIDE KEYSTONE
BLANKING
ASPECT RATIO [4:3]
OPTIONS
Select with↑or↓
then 
 to return
Menu 7-42
2. PressENTERto select.
3. Push the cursor key↑or↓to size the image in a vertical direction.
Push the cursor key←or→to size the image in a horizontal direction.
While the bar scale window is on the screen, press ENTER to change the value indication to an input field.
Enter...

Page 86

7. Random Access Adjustment Mode
While the bar scale window is on the screen, press ENTER to change the value indication to an input field.
Enter the desired value with the numeric keys on the RCU. Always 3 digits should be entered. To toggle + to -
or vice versa, use the up or down arrow key.
7.4.6 Blanking
What can be done ?
Blanking adjustments affect only the edges of the projected image and are used to frame the projected image on to the screen and
to hide or black out unwanted information (or...

Page 87

7. Random Access Adjustment Mode
2. PressENTERto display the blanking menu.
BLANKING
TOP
BOTTOM
LEFT
RIGHT
Select with↑or↓
then 
 to return
Menu 7-45
3. Push the cursor key↑or↓to highlight the desired blanking.
4. PressENTERto start up the chosen blanking.
5. Use the cursor keys to adjust the blanking.
While the bar scale window is on the screen, press ENTER to change the value indication to an input field.
Enter the desired value with the numeric keys on the RCU. Always 3 digits should be entered. To...

Page 88

7. Random Access Adjustment Mode
TheGeometry Optionsmenu will be displayed.
GEOMETRY OPTIONS
Use the same side
keystone correction
for all files ?
[YES]
 to toggle
 to return
Menu 7-48
3. PressENTERto toggle between [YES] or [NO].
NO Side Keystone will be adjusted for the active file only.
YES Side Keystone will be adjusted for all files.
7.5 ScenergiX
Overview
• Order information
• Introduction
• Preparations
• Scenergix
• ScenergiX overlap zone (horizontal scenergix)
• ScenergiX overlap zone (vertical...

Page 89

7. Random Access Adjustment Mode
Image 7-8
Why Soft Edge?
What is the Basic Principal of ScenergiX ?
The principle of edge blending is archived by linear modulation of the light output in the overlap zone so that the light output in that
zone equals the light output of the rest of the image.
Adjustable overlapping area
50% 100%50% 100%
image 2 image 1
image 2 image 1
Light output per image
Total composite light output
Image 7-9
ScenergiX Basic Principle
7.5.3 Preparations
ScenergiX Preparations
To ensure...

Page 90

7. Random Access Adjustment Mode
2. PressENTERto select.
3. Push the cursor key↑or↓to highlightStatus.
SCENERGIX
STATUS [ON]
- size -
TOP
BOTTOM
LEFT
RIGHT
- black level -
LEVEL
Select with↑or↓
then 
 to return
Menu 7-50
4. PressENTERto toggle between ON and OFF.
ONscenergix is active
OFFscenergix is not active
7.5.5 ScenergiX overlap zone (horizontal scenergix)
Definitions
Image 7-10
Scenergix set up
Overlap : number of pixels that overlap
Horizontal resolution of 1 projector : 1024 for Graphics...
Start reading Barco Slm R12+ Owners Manual