11. Lamp 11 . L A M P Overview • Lamp menu overview • Lamp power mode • Lamp power • Auto dimming when on Pause • Auto dimming when No Signal • Auto dimming when Over-temperature • CLO mode (Constant light output mode) • CLO targets • LPS power • Lamp identification • Z-axis adjustment R5905032 HDX SERIES 23/11/2011 177
11. Lamp 11.1 Lamp menu overview Overview table Level 1 Level 2 Level 3 Lamp Power Power mode Power Auto dimming when pause Auto dimming when No Signal Auto dimming when Overtemperature CLO mode CLO targets LPS Power Identification Z-axis Light output 178 R5905032 HDX SERIES 23/11/2011
11. Lamp 11.2 Lamp power mode What can be done? The lamp power mode can be switched betweenNormalandEconomic. When playing in Economic mode, the lamp life time will be higher than in normal mode. The counter of the lamp life time counts equal for normal or economic mode but the customer will see that the ageing of the lamp is lower in economic mode. Normal : maximum allowed power is fed to the lamp. Maximum light output is reached in this way. Economic : a reduced wattage is fed to the lamp. Reduced light output but a longer life time for the lamp. The lamp power mode setting is linked with the CLO mode setting. When CLO mode settings is set toOn, the lamp power mode setting is ignored and projector will play in CLO mode. Once the CLO mode setting is switched toOff, the installed lamp power mode setting will be used. How to switch 1. PressMenuto activate the menus and selectLamp→Power→Mode. Image 11-1 Main menu, lamp Image 11-2 Lamp, power Image 11-3 2. PressENTERto toggle between[Normal]and[Economic]. R5905032 HDX SERIES 23/11/2011 179
11. Lamp 11.3 Lamp power What can be done? Within a certain power mode, the light output of the lamp can be reduced by reducing the lamp power How to reduce the power 1. PressMenuto activate the menus and selectLamp→Power→Power. Image 11-4 Main menu, lamp Image 11-5 Lamp, power Image 11-6 Lamp power adjustment 2. Use the◄or►key to change the power value. The value can be changed between 75 and 100% 180 R5905032 HDX SERIES 23/11/2011
11. Lamp 11.4 Auto dimming when on Pause About auto dimming when on pause When the projector is switched to pause, the shutter is closed but the lamp is still running on full power. When auto dimming on pause is activated, then the lamp power will be reduced from its current value to its minimum value. When returning out of pause the lamp power is restored to its previous value. How to set up 1. PressMenuto activate the menus and selectLamp→Power→Auto Dimming when Pause. Image 11-7 Main menu, lamp Image 11-8 Lamp, power Image 11-9 Auto dimming when Pause 2. PressENTERto toggle between[On]or[Off]. [On] : when switched to pause, lamp power will be reduced. [Off] : when switched to pause, power remains on its original value. R5905032 HDX SERIES 23/11/2011 181
11. Lamp 11.5 Auto dimming when No Signal About auto dimming When no signal is detected on the selected input the lamp power will be reduced from the current value to its minimum value. When the input signal is re-detected, the lamp power is restored to its original value. This function is a duplicate of the Auto dimming in the Input menu. How to set up 1. PressMenuto activate the menus and selectLamp→Power→Auto Dimming No Signal. Image 11-10 Main menu, lamp Image 11-11 Lamp, power Image 11-12 Auto dimming no signal 2. PressENTERto toggle between[On]or[Off]. [On] : when no signal, auto dimming is started. [Off] : when no signal, no auto dimming is started. 182 R5905032 HDX SERIES 23/11/2011
11. Lamp 11.6 Auto dimming when Over-temperature What can happen? When an over-temperature is detected, the projector starts dimming the lamp so that the projector can cool down. How to set up 1. PressMenuto activate the menus and selectLamp→Power→Auto Dimming Overtemperature. Image 11-13 Main menu, lamp Image 11-14 Lamp, power Image 11-15 Auto dimming over-temperature 2. PressENTERto toggle between[On]or[Off]. [On] : when temperature is to high, auto dimming is started. [Off] : when temperature is to high, no auto dimming is started. R5905032 HDX SERIES 23/11/2011 183
11. Lamp 11.7 CLO mode (Constant light output mode) What can be done? Constant Light Output allows to force a constant light output (set in theCLO Target lumensitem) of the projector over a certain period. This will eliminate uncontrolled light output drop caused by natural aging of the lamp. The light output is checked every 5 minutes, if the target is not met, the lamp power is adjusted. Setting CLO off means that the lamp will operate at constant power (no power adaptation to meet constant light output). In the illustration below, a normal light output curve is shown over thefirst 1000 hours, image 11-16. Byusing CLO and setting the target to 60% of the maximum light output, one will be able to operate during approximately 500 hours with a constant light output, image 11-17. 100 20 40 60 80 200 400 600 800 1000 Relative Light Output (%) Runtime (hrs) Image 11-16 100 20 40 60 80 200 400 600 800 1000 Relative Light Output (%) Runtime (hrs) Constant Light Output working area Image 11-17 CLO mode setting On overrules the lamp power mode setting. Projector will always play in CLO mode using the CLO target. How to switch CLO mode 1. PressMenuto activate the menus and selectLamp→Power→CLO mode. 184 R5905032 HDX SERIES 23/11/2011
11. Lamp Image 11-18 Main menu, lamp Image 11-19 Lamp, power Image 11-20 Power, CLO mode 2. PressENTERto toggle between[On]or[Off]. R5905032 HDX SERIES 23/11/2011 185
11. Lamp 11 . 8 C L O t a r g e t s What must be done? The light output target can be set. This value will force the projector to produce the target lumens when the CLO mode is set toOn. How to set the target 1. PressMenuto activate the menus and selectLamp→Power→CLO mode. Image 11-21 Main menu, lamp Image 11-22 Lamp, power Image 11-23 CLO Target lumens setup 2. Use the◄or►key to change the CLO target lumens. 186 R5905032 HDX SERIES 23/11/2011