ASAI and Domain Controlbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Considerationsbbbbbbbbbbbbbbb DTMF signals may be sent to any extension type on the call. If a character sequence with a length greater than 32 is supplied, only the first 32 characters in the sequence will be accepted (the remaining characters will be ignored). 5-30 Issue 4 September 1995
ASAI and Domain Controlbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Third Party Domain Control Endedbbbbbbbb This capability is used by the switch to inform an application that a domain-control association has been terminated because the domain was removed or changed to become an invalid domain by administration. Information Flowbbbbbbbbbbbbbbb The switch does not expect a response. Third Party Domain Control Endedbbbbbbbbbbbbbbb None for this capability ACK (Positive Acknowledgement) Parameters bbbbbbbbbbbbbbb None for this capability Denial (NAK) Causesbbbbbbbbbbbbbbb None for this capability Protocol Error (NAK) Causebbbbbbbbbbbbbbb None for this capability Issue 4 September 1995 5-31
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb bbbbb Event Notification Capabilities 6 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb This chapter describes the Notification Capability Group. The capabilities available in this group allow the adjunct to request and cancel event reporting on new calls. The following capabilities are available: Event Notification RequestThis capability enables the adjunct to direct the switch to send event reports for new calls entering an ACD split or VDN domain. Event Notification CancelThis capability enables the adjunct to direct the switch to cancel event reports for a specified domain. Stop Call NotificationThis capability enables the adjunct to direct the switch to stop sending event reports for a chosen call within the domain. Event Notification EndedThis capability allows the switch to notify the adjunct when a monitored domain becomes invalid (via administration) for event notification. Event ReportSee Chapter 3, ``Common Capabilities. U-Abort (User Abort)See Chapter 3, ``Common Capabilities. Issue 4 September 1995 6-1
Event Notification Capabilitiesbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Event Notification Requestbbbbbbbb This capability enables the adjunct to request notification for calls entering domains of VDNs and ACD splits. The requested ACD splits must not be adjunct-controlled 1 or vector-controlled.2 DEFINITY G3V3 and later allows a maximum of three notification associations to get events for a call. Information Flowbbbbbbbbbbbbbbb The adjunct expects a response to its request. The switch checks for a valid domain value and either accepts or denies the request. Event Notification Request Parametersbbbbbbbbbbbbbbb domain typeThis parameter must be a VDN or ACD split. domain valueThis parameter must be a valid VDN or ACD split extension. The requested ACD splits must not be adjunct-controlled (via switch administration) or vector- controlled. ACK (Positive Acknowledgement) Parameters bbbbbbbbbbbbbbb None for this capability Denial (NAK) Causesbbbbbbbbbbbbbbb The switch issues the following reason as the cause for not executing the request: Requested facility (capability) not subscribed/provisioned (CS0/50) The user has not subscribed for the requested capability. aaaaaaaaaaaaaaaaaaa 1. Adjunct-controlled splits are ACD splits with this property administered on the Hunt Group form. Such splits accept only adjunct-originated calls, not off-net, incoming calls. Thus, event notification can be provided, but only via Third Party Make Call associations. See the DEFINITY Communications System Generic 3 Feature Description, 555-230-204, for more information. 2. Vector-controlled splits are hunt groups that can only be accessed through a VDN. If notification is desired, it can be requested for the VDN that controls the split. See the DEFINITY Communications System Generic 3 Feature Description, 555-230-204, and the DEFINITY Communications System Generic 3 Call Vectoring Guide, 555-230-520, for more information. 6-2 Issue 4 September 1995
Event Notification Capabilitiesbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Service or option not implemented (CS3/63) The given domain is already being monitored by up to 3 ASAI applications (G3V3 and later). Mandatory information element missing (CS0/96) A required parameter is missing in the request (for example, domain type). Resources not available (CS3/40) The request cannot be executed because the system limit would be exceeded for the maximum number of event notifications. Invalid Number/Domain (CS0/28) The domain value is neither a valid VDN nor a valid ACD split extension. The call is not monitored by the requesting association. Switch not administered correctly (CS3/41) The domain value is an adjunct-controlled split or a vector-controlled split. Switching Equipment Congestion (CS0/42) The switch is not accepting the request at this time because of traffic overload. The adjunct or user may wish to retry the request but should not do so immediately. Invalid association (CS0/81) The association is already in existence. Service or option not available (CS3/63) A maximum of three notification associations to monitor an ACD split or VDN domain can be active for a specific ACD split or VDN. Protocol Error (NAK) Causebbbbbbbbbbbbbbb Protocol error (CS0/111) The Q.932 protocol has been violated. NOTE: For more information regarding protocol errors and a complete list of reason codes (cause values), see the DEFINITY Communications System CallVisor ASAI Protocol Reference , 555-230-221. Considerationsbbbbbbbbbbbbbbb When monitoring is established for a domain, the switch generates event reports as calls arrive at the domain. The switch does not generate event reports for calls that are already present (in progress) at the domain when the Request Notification is received. An ACD split or a VDN have can have up to three Event Notification Request associations active at any one time (G3V3 and later). Prior to G3V3, there could be only one. A call can be reported on by up to three Event Notification associations at a time (G3V3 and later). Issue 4 September 1995 6-3
Event Notification Capabilitiesbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Event Notification Cancelbbbbbbbb This capability enables the adjunct to cancel any notification request (for all calls) for a given domain only for the association that received the request. Information Flowbbbbbbbbbbbbbbb The switch always accepts the request. If the request is not understood by the switch or is received over a non-Event Notification association, the switch aborts the association. See Chapter 3, ``Common Capabilities, for more information regarding the U-Abort capability. Event Notification Cancel Parametersbbbbbbbbbbbbbbb None for this capability ACK (Positive Acknowledgement) Parameters bbbbbbbbbbbbbbb None for this capability Denial (NAK) Causebbbbbbbbbbbbbbb The switch issues the following reason as the cause for not executing the request. Invalid association (CS0/81) The association does not exist. Protocol Error (NAK) Causebbbbbbbbbbbbbbb The switch issues the following cause for generating a protocol processing error: Protocol error (CS0/111) The Q.932 protocol has been violated. NOTE: For more information regarding protocol errors and a complete list of reason codes (cause values), see the DEFINITY Communications System Generic 3 CallVisor ASAI Protocol Reference , 555-230-221. Considerationsbbbbbbbbbbbbbbb The cancel notification takes effect immediately. Event reports to the adjunct for calls in progress cease over this particular association. 6-4 Issue 4 September 1995
Event Notification Capabilitiesbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Stop Call Notificationbbbbbbbb This capability enables the adjunct to request that the switch stop sending event reports for a particular call, identified by the call_id parameter, over an Event Notification association. Information Flowbbbbbbbbbbbbbbb The switch accepts or denies the request. Stop Call Notification Parameterbbbbbbbbbbbbbbb call_idThis parameter indicates the call for which no further event notification is requested. ACK (Positive Acknowledgement) Parameter bbbbbbbbbbbbbbb None for this capability Denial (NAK) Causesbbbbbbbbbbbbbbb The switch issues the following reason as the cause: Invalid information element contents (CS0/100) The call_id parameter is outside the allowable range for the switch. Invalid number domain (CS0/28) The specified call is not monitored by the requesting association. Protocol Error (NAK) Causebbbbbbbbbbbbbbb The switch issues the following reason as the cause for not executing the requested operation: Protocol error (CS0/111) The Q.932 protocol has been violated. NOTE: For more information regarding protocol errors, see the DEFINITY Communications System Generic 3 CallVisor ASAI Protocol Reference , 555-230-221. Issue 4 September 1995 6-5
Event Notification Capabilitiesbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Considerationsbbbbbbbbbbbbbbb Only one call_id per request is allowed. This capability can be requested by an adjunct at any time during the life of a monitored call. The request must be sent over the same Event Notification association that receives event reports for the call. After this capability is invoked, a call may subsequently become monitored again if it enters another event notification domain or through other active event notification associations. 6-6 Issue 4 September 1995
Event Notification Capabilitiesbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Event Notification Endedbbbbbbbb This capability is used by the switch to notify the adjunct that, through switch administration, a domain with monitoring has become an invalid domain. Information Flowbbbbbbbbbbbbbbb The adjunct does not respond to this capability. The switch does not expect any acknowledgements (either positive or negative) from the informed adjunct and stops Event Notification for the calls automatically. Event Notification Ended Parameterbbbbbbbbbbbbbbb CauseInvalid Number/Domain (CS0/28) The domain is no longer available or valid. ACK (Positive Acknowledgement) Parameters bbbbbbbbbbbbbbb None for this capability Denial (NAK) Causebbbbbbbbbbbbbbb None for this capability Protocol Error (NAK) Causebbbbbbbbbbbbbbb None for this capability Considerationsbbbbbbbbbbbbbbb The monitoring must have previously been requested by use of the Event Notification Request capability. Issue 4 September 1995 6-7