Home > ATT > Communications System > ATT DEFINITY Communications System Generic 3V4 Instructions Manual

ATT DEFINITY Communications System Generic 3V4 Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual ATT DEFINITY Communications System Generic 3V4 Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 397
    							ASAI and Domain Controlbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Considerationsbbbbbbbbbbbbbbb
    DTMF signals may be sent to any extension type on the call.
    If a character sequence with a length greater than 32 is supplied, only the
    first 32 characters in the sequence will be accepted (the remaining
    characters will be ignored).
    5-30  Issue 4  September 1995 
    						
    							ASAI and Domain Controlbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Third Party Domain Control Endedbbbbbbbb
    This capability is used by the switch to inform an application that a
    domain-control association has been terminated because the domain was
    removed or changed to become an invalid domain by administration.
    Information Flowbbbbbbbbbbbbbbb
    The switch does not expect a response.
    Third Party Domain Control Endedbbbbbbbbbbbbbbb
    None for this capability
    ACK (Positive Acknowledgement)
    Parameters
    bbbbbbbbbbbbbbb
    None for this capability
    Denial (NAK) Causesbbbbbbbbbbbbbbb
    None for this capability
    Protocol Error (NAK) Causebbbbbbbbbbbbbbb
    None for this capability
    Issue 4  September 1995  
    5-31 
    						
    							bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
       
    						
    							bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    bbbbb
    Event Notification Capabilities
    6
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    This chapter describes the Notification Capability Group.  The capabilities
    available in this group allow the adjunct to request and cancel event reporting on
    new calls.
    The following capabilities are available:
    Event Notification
    RequestThis capability enables the adjunct to direct
    the switch to send event reports for new calls
    entering an ACD split or VDN domain.
    Event Notification
    CancelThis capability enables the adjunct to direct
    the switch to cancel event reports for a
    specified domain.
    Stop Call NotificationThis capability enables the adjunct to direct
    the switch to stop sending event reports for a
    chosen call within the domain.
    Event Notification
    EndedThis capability allows the switch to notify the
    adjunct when a monitored domain becomes
    invalid (via administration) for event
    notification.
    Event ReportSee Chapter 3, ``Common Capabilities.
    U-Abort (User Abort)See Chapter 3, ``Common Capabilities.
    Issue 4  September 1995  
    6-1 
    						
    							Event Notification Capabilitiesbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Event Notification Requestbbbbbbbb
    This capability enables the adjunct to request notification for calls entering
    domains of VDNs and ACD splits.  The requested ACD splits must not be
    adjunct-controlled
    1 or vector-controlled.2
    DEFINITY G3V3 and later allows a maximum of three notification associations to
    get events for a call.
    Information Flowbbbbbbbbbbbbbbb
    The adjunct expects a response to its request.
    The switch checks for a valid domain value and either accepts or denies the
    request.
    Event Notification Request Parametersbbbbbbbbbbbbbbb
    domain typeThis parameter must be a VDN or ACD split.
    domain valueThis parameter must be a valid VDN or ACD split
    extension.  The requested ACD splits must not be
    adjunct-controlled (via switch administration) or vector-
    controlled.
    ACK (Positive Acknowledgement)
    Parameters
    bbbbbbbbbbbbbbb
    None for this capability
    Denial (NAK) Causesbbbbbbbbbbbbbbb
    The switch issues the following reason as the cause for not executing the
    request:
    Requested facility (capability) not subscribed/provisioned (CS0/50)
    The user has not subscribed for the requested capability.
    aaaaaaaaaaaaaaaaaaa
    1.  Adjunct-controlled splits are ACD splits with this property administered on the Hunt Group form.  Such splits
    accept only adjunct-originated calls, not off-net, incoming calls. Thus, event notification can be provided, but
    only via Third Party Make Call associations. See the 
    DEFINITY Communications System Generic 3 Feature
    Description, 555-230-204, for more information.
    2. Vector-controlled splits are hunt groups that can only be accessed through a VDN. If notification is desired, it
    can be requested for the VDN that controls the split.  See the 
    DEFINITY Communications System Generic 3
    Feature Description, 555-230-204, and the DEFINITY Communications System Generic 3 Call Vectoring Guide,
    555-230-520, for more information.
    6-2  Issue 4  September 1995 
    						
    							Event Notification Capabilitiesbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Service or option not implemented (CS3/63)
    The given domain is already being monitored by up to 3 ASAI applications
    (G3V3 and later).
    Mandatory information element missing (CS0/96)
    A required parameter is missing in the request (for example, domain type).
    Resources not available (CS3/40)
    The request cannot be executed because the system limit would be
    exceeded for the maximum number of event notifications.
    Invalid Number/Domain (CS0/28)
    The domain value is neither a valid VDN nor a valid ACD split extension.
    The call is not monitored by the requesting association.
    Switch not administered correctly (CS3/41)
    The domain value is an adjunct-controlled split or a vector-controlled split.
    Switching Equipment Congestion (CS0/42)
    The switch is not accepting the request at this time because of traffic
    overload.  The adjunct or user may wish to retry the request but should
    not do so immediately.
    Invalid association (CS0/81)
    The association is already in existence.
    Service or option not available (CS3/63)
    A maximum of three notification associations to monitor an ACD split or
    VDN domain can be active for a specific ACD split or VDN.
    Protocol Error (NAK) Causebbbbbbbbbbbbbbb
    Protocol error (CS0/111)
    The Q.932 protocol has been violated.
    NOTE:
    For more information regarding protocol errors and a complete list of
    reason codes (cause values), see the 
    DEFINITY Communications
    System CallVisor ASAI Protocol Reference
    , 555-230-221.
    Considerationsbbbbbbbbbbbbbbb
    When monitoring is established for a domain, the switch generates event reports
    as calls arrive at the domain.  The switch does not generate event reports for
    calls that are already present (in progress) at the domain when the Request
    Notification is received.
    An ACD split or a VDN have can have up to three Event Notification Request
    associations active at any one time (G3V3 and later). Prior to G3V3, there could
    be only one.
    A call can be reported on by up to three Event Notification associations at a time
    (G3V3 and later).
    Issue 4  September 1995  
    6-3 
    						
    							Event Notification Capabilitiesbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Event Notification Cancelbbbbbbbb
    This capability enables the adjunct to cancel any notification request (for all calls)
    for a given domain only for the association that received the request.
    Information Flowbbbbbbbbbbbbbbb
    The switch always accepts the request.  If the request is not understood by the
    switch or is received over a non-Event Notification association, the switch aborts
    the association.  See Chapter 3, ``Common Capabilities, for more information
    regarding the U-Abort capability.
    Event Notification Cancel Parametersbbbbbbbbbbbbbbb
    None for this capability
    ACK (Positive Acknowledgement)
    Parameters
    bbbbbbbbbbbbbbb
    None for this capability
    Denial (NAK) Causebbbbbbbbbbbbbbb
    The switch issues the following reason as the cause for not executing the
    request.
    Invalid association (CS0/81)
    The association does not exist.
    Protocol Error (NAK) Causebbbbbbbbbbbbbbb
    The switch issues the following cause for generating a protocol processing error:
    Protocol error (CS0/111)
    The Q.932 protocol has been violated.
    NOTE:
    For more information regarding protocol errors and a complete list of
    reason codes (cause values), see the 
    DEFINITY Communications
    System Generic 3 CallVisor ASAI Protocol Reference
    , 555-230-221.
    Considerationsbbbbbbbbbbbbbbb
    The cancel notification takes effect immediately.  Event reports to the adjunct for
    calls in progress cease over this particular association.
    6-4  Issue 4  September 1995 
    						
    							Event Notification Capabilitiesbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Stop Call Notificationbbbbbbbb
    This capability enables the adjunct to request that the switch stop sending event
    reports for a particular call, identified by the call_id parameter, over an Event
    Notification association.
    Information Flowbbbbbbbbbbbbbbb
    The switch accepts or denies the request.
    Stop Call Notification Parameterbbbbbbbbbbbbbbb
    call_idThis parameter indicates the call for which
    no further event notification is requested.
    ACK (Positive Acknowledgement)
    Parameter
    bbbbbbbbbbbbbbb
    None for this capability
    Denial (NAK) Causesbbbbbbbbbbbbbbb
    The switch issues the following reason as the cause:
    Invalid information element contents (CS0/100)
    The call_id parameter is outside the allowable range for the switch.
    Invalid number domain (CS0/28)
    The specified call is not monitored by the requesting association.
    Protocol Error (NAK) Causebbbbbbbbbbbbbbb
    The switch issues the following reason as the cause for not executing the
    requested operation:
    Protocol error (CS0/111)
    The Q.932 protocol has been violated.
    NOTE:
    For more information regarding protocol errors, see the DEFINITY
    Communications System Generic 3 CallVisor ASAI Protocol
    Reference
    , 555-230-221.
    Issue 4  September 1995  
    6-5 
    						
    							Event Notification Capabilitiesbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Considerationsbbbbbbbbbbbbbbb
    Only one call_id per request is allowed.
    This capability can be requested by an adjunct at any time during the life of a
    monitored call.  The request must be sent over the same Event Notification
    association that receives event reports for the call.
    After this capability is invoked, a call may subsequently become monitored again
    if it enters another event notification domain or through other active event
    notification associations.
    6-6  Issue 4  September 1995 
    						
    							Event Notification Capabilitiesbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Event Notification Endedbbbbbbbb
    This capability is used by the switch to notify the adjunct that, through switch
    administration, a domain with monitoring has become an invalid domain.
    Information Flowbbbbbbbbbbbbbbb
    The adjunct does not respond to this capability.
    The switch does not expect any acknowledgements (either positive or negative)
    from the informed adjunct and stops Event Notification for the calls automatically.
    Event Notification Ended Parameterbbbbbbbbbbbbbbb
    CauseInvalid Number/Domain (CS0/28)
    The domain is no longer available or valid.
    ACK (Positive Acknowledgement)
    Parameters
    bbbbbbbbbbbbbbb
    None for this capability
    Denial (NAK) Causebbbbbbbbbbbbbbb
    None for this capability
    Protocol Error (NAK) Causebbbbbbbbbbbbbbb
    None for this capability
    Considerationsbbbbbbbbbbbbbbb
    The monitoring must have previously been requested by use of the Event
    Notification Request capability.
    Issue 4  September 1995  
    6-7 
    						
    All ATT manuals Comments (0)

    Related Manuals for ATT DEFINITY Communications System Generic 3V4 Instructions Manual