Page 51
[email protected] 51 Yield +Angle Selecting this strategy in “General data” tab of “Freedom wrenches Tightening program definition”, Freedom³ will detect automatically the yield point, after detection, user has to continue to tighten reaching a specific angle ( Nominal Angle).In case the Yiled point is not recognized, Freedom³ will display an error message. The Angle value is counted starting from Yield point. The result will be considered “OK” if the angle and torque...
Page 53
[email protected] 53 Fields And Meaning Table for “Freedom wrenches tightening program definition” Tool Tab: Fields Meaning Tool Nr. =t’s the identification number of the tool (end fitting) Torque Correction Factor =t’s a torque factor. User must fill this field only if on the wrench is plugged an extension that modifies the original calibration length. See figure below to calculate the factor< Angle Correction Factor =t’s an angle factor. User must fill tUis field...
Page 54
54 - Click on Leds Tab Note: In this page is possible to customize the percentage to light every single led on the wrench considering the target.
Page 55
[email protected] 55 - Click on Batch Tab Note: Inside Batch Tab is possible to multiply the number of screws to tighten. For example, usually to mount a wheel on the car there are 4 or 5 screws to tighten with the same strategy for all screws. =n this Tab is possible to define how many screws “Freedom³ has to tighten”.
Page 56
56 See table below to fill correctly all fields. Fields Meaning Screws nr In this field, user has to indicate the number of screws to tighten with Freedom³ (for example if there are 3 screws, SQ-net will send to Freedom³ 3 time the same tightening program) Enable batch Click on check box in order to enable Batch function Strategy In this field is possible to define the strategy in order to drive the wrench considering the status of the tightening: Count only ok results->...
Page 57
[email protected] 57 How to create a route A route is a group of Control Quality test or tightening strategy. Freedom³ can receive Control Quality route, Tightening Program route or both. To send tests or tightening programs from SQ- Net to Freedom³, user must create a route in SQ-Net and send it. From SQ-Net front page, select route management icon: Route Management Icon
Page 59
[email protected] 59 In route management window is possible : ICON FUNCTIONS Select an existing route in order to add or remove test Edit a new route Modify a route Delete a route Add and remove test from route Select test from route Click on new route to create a new one
Page 60
60 =t will appear a new window “Add a new route”: Here, user must select the right type of route: Quality Control: if in the route there are only Quality Control Test Freedom wrenches programs: if in the route there are only tightening programs Mix: if in the route there are Quality Control Test and Tightening programs