Page 31

 
 
   [email protected]     
31  
See table below for the mining of every single icon: 
 
 
ICON FUNCTION 
 
Edit New Test 
 
Select Quality Control for Tightening Test 
 
Modify a test 
 
Delete a test 
 
Statistic 
 
Manual insert of test 
 
Add curve to a composition 
 
Add the selected test to an existing route 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  

Page 32

32 
 
 
Follow next step to edit a new test:  
 
 
 
 
Click on New test 
 
 
 
 
 
 
 
Move the mouse on  QC 
 
 
 
 
 
 
 
 
 
 
SPC Quality Control  test 
(For Freedom³ and DataTouch³) 
 
 
 
SPC Production tool test 
(only for DataTouch³) 
 
 
 
 
 
 
User has to select the test to link to the location, selected the right control strategy for SPC Quality 
Control test.SPC Production Tool Test is only available for DataTouch³, for this kind of test is 
necessary to connect a rotary or static...

Page 33

 
 
   [email protected]     
33  
Quality Control Test 
 
 
Breakaway Test  
=t’s a Quality Control test, user has to over-tightening  joint already screwed. Selecting this test 
user has to specify the strategy: peak; torque/angle; smart  breakaway (see the table “field and 
meaning” for more information). 
 
 
Test parameters 
Selecting Breakaway test, it will be appear a new window  to fill in order to set test parameters....

Page 34

34 
 
 
 
 
See table below for the mining of every field of “test parameters” tab: 
 
Fields Meaning 
Stat Group Size =t’s a minimum number of measure to create a statistic chart 
Nr of measurementV =t’s a number of samples to complete a test on Freedom

Page 35

 
 
   [email protected]     
35  
Tool 
User has to fill this section only if on the wrench used for the breakaway, is added an extension 
that modifies the original length of the wrench or modifies the angle reading (long and flexible 
extension introduce an error in the torque and angle reading). 
 
 
 
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
       
 
 
 
            
Fields Meaning 
Tool nr. =t’s the id number of the extension 
Length (mm) =t’s the  length of the extension tool 
Angle...

Page 36

36 
 
Peak  
Selecting in test parameters “test type: peak” user has to fill the threshold value for this strategy. 
Example if the threshold value is 10 Nm, Freedom³ will consider as result only the peak torque 
over 10 Nm. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  

Page 37

 
 
   [email protected]     
37  
Torque/angle 
Selecting in test parameters “Test Type: Torque angle” user has to set “Threshold and Angle 
Detection values”. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Using this Breakaway strategy, Freedom³ will collect as result the torque value after a specific 
angle. The angle counting will start after a specific torque value “threshold”. 
For example: if the threshold value is 10 Nm and the angle value is 3°, Freedom³ will consider as 
result the torque...

Page 38

38 
 
Smart 
Using this strategy, Freedom³ will recognize automatically the breakaway point. User has to set: 
the start torque and angle reading (Threshold); Torque Alarm is the max torque operator can 
reach (after this specific value Freedom³ will display the message “change screw”, in order to do 
not run any risk to let a broken joint after test); Angle alarm is the max angle operator can reach 
(after this value Freedom³ will display an alarm message); select “No dynamic breakaway” for first 
peak...

Page 39

 
 
   [email protected]     
39  
Loose  and Tightening Test 
=t’s a Quality Control test, selecting this test Freedom³ will consider as a result the torque value 
reached after user loose and tighten again the bolt exactly to the original position (For more info 
see paragraph Loose and Tightening test in Freedom³ LAB mode). 
 
 
  
 
 
 
To fill all fields see the table “field and meaning”. 
Loose angle (°)  In this field user has to indicate how many degree the bolt must be unscrewed. 
The test...

Page 40

40 
 
Min Torque Test 
=t’s  a Quality Control Test, selecting this test, Freedom³ will consider as result the torque value 
over-tightening a bolt already screwed for a specific angle. The goal of this test is to check if a bolt 
is tightened and to check if it’s  enough tightened  (For more info see paragraph Min Torque test in 
Freedom³ LAB mode). 
 
 
 
 
 
To fill all fields see the table “field and meaning”. 
Nominal Torque  =t’s the minimum expected torque after the bolt is over tightened for a...