Page 81
[email protected] 81 How to run test from route - Freedom³ SPC - From the main page of Freedom³ select the type of test to run “Process Capability” or “Cp/Cm”: Selecting Process Capability, it will appear on the display: Freedom³ shows root and folders in the same way were created in SQ-net, but every single folder corresponds a single page on Freedom³. Press “right arrow” on Freedom³ keyboard to display next folder.
Page 82
82 The second level folder will appear (like SQ-net): Press again the “right arrow” on Freedom³ keyboard for third level folder:
Page 83
[email protected] 83 Pressing again “right arrow” Freedom³ will display tests regarding the specific location: Select the test by “Up” and “Down” arrows and press confirm on Freedom³ Keyboard. A new window will appear: TORQUE ANGLE The wrench is ready to tighten
Page 84
84 At the end of tightening Freedom³ will show the results: The results in green color are inside tolerances, in red colors are outside. At the end of the test, Freedom³ will display the list of test related to the location with the status of last test: Number of tests done and grup size ( see paragrafh SPC QualityControl Test and SPC Production Tool Test) Message about status of measure
Page 85
[email protected] 85 How to run test from route - Freedom³ PRW - From main page of Freedom³ is possible to choose the type of test to run “Select Program” or “Select Hob”. Select Program -> If user wants select the operation to run one by one without following any sequence Select Job -> If user wants to follow a sequence of operation or only have a specific part of route test (group) Select Program On main page of Freedom³ touch “Select Program”: =f enabled,...
Page 86
86 =n “Select Program” page is possible to select from which operation user will start. Operations Once the program is select press confirm on Freedom³ keyboard, the wrench is ready: Number of test to do Operation name Target and tolerance limits Units of measurements Progression bar Message for operator Now operator can start to tighten up the target.
Page 87
[email protected] 87 If the torque and angle results will be in side tolerance limits, Freedom³ will display torque and angle value with green color. Otherwise, if torque or angle are outside of tolerance limits, the out value will be displayed with red color. In case torque and angle are out of tolerance limits, both will be displayed with red color. =n case of “Not OK” result Freedom³ will display a message “Confirm” pushing confirm button on keyboard or “Discard” pushing left...
Page 88
88 =n the example above there is only one “Hob”, user can create more jobs in a route. Once the “Hob” is selected press confirm on Freedom³ keyboard to start the job. Depending from the sequence of every single operation (see paragraph, how create a route) Freedom³ will start the job from first operation and the operator must follow the sequence specified in the job. When all operation complete last “screw” of last operation Freedom³ will display the message “Hob completed”. During the...
Page 89
[email protected] 89 When the Hob is finished, push on “ESC” keyboard button, to go back to main menu or select another job. =t’s also possible repeat the same job, Freedom³will store all data-results in the memory. For every test Freedom³ save data-results and curves (Torque/Time,Torque/angle). See paragraph “Freedom³ PRW “:ow to send data-results to SQnet””
Page 90