Page 71
Fading Scenes71 01V96i—Reference Manual Scene Memories Fading Scenes You can specify the time it takes the Input and Output Chan- nel faders (or level controls) to move to their new positions when a Scene is recalled. This is called Fade Time, and it can be set for each channel in the range of 00.0 through 30.0 sec- onds (in 0.1 second steps). You can set the Fade Time for each Scene individually or for all Scenes globally. Fading Input Channels To set the Fade Time for Input Channels 1–32 and ST IN...
Page 72
72Scene Memories 01V96i—Reference Manual Recalling Scenes Safely When a Scene is recalled, all mix parameters are set accord- ingly. However, in some situations, you can retain the cur- rent settings of certain parameters on certain channels by using the Recall Safe function. You can set the Recall Safe function parameters for each Scene individually or for all Scenes globally. To set the Recall Safe function, press the DISPLAY ACCESS [SCENE] button repeatedly until the Scene | Rcl Safe page...
Page 73
Copying and Pasting a Scene (Global Paste)73 01V96i—Reference Manual Scene Memories Copying and Pasting a Scene (Global Paste) Any channel or parameter settings for the current scene can be copied and pasted into one or more scenes. This function is useful when you want to apply edited parameter settings in the current scene to other scenes. 1.Press the DISPLAY ACCESS [SCENE] button repeatedly until the Paste SRC page appears. 2.Use the cursor buttons, [SEL] buttons, or Parameter wheel to select...
Page 74
74Libraries 01V96i—Reference Manual Libraries This chapter describes the 01V96i’s various libraries. About the Libraries The 01V96i features seven libraries that enable you to store Channel, Input Patch, Output Patch, Effects, and other data. You can also quickly recall this data from the libraries to restore previous parameter values. The 01V96i offers the following libraries: • Channel Library •Input Patch Library • Output Patch Library •Effects Library •Gate Library •Compressor Library •EQ Library...
Page 75
Using Libraries75 01V96i—Reference Manual Libraries Using Libraries Channel Library Channel library enables you to store and recall Input Channel and Output Channel parameter settings. The library contains two preset memories and 127 user (readable & writable) memories. You can recall only the settings for the currently-selected channels from the Channel library. For example, you cannot recall Input Channel 1–32 settings to ST IN Channels 1–4, Bus Outs 1–8, Aux Outs 1–8, or Stereo Out, with the...
Page 76
76Libraries 01V96i—Reference Manual Output Patch Library The Output Patch library enables you to store and recall all Output Patch settings. The library contains one preset mem- ory and 32 user (readable & writable) memories. To access the Output Patch library, press the DISPLAY ACCESS [PATCH] button repeatedly until the Patch | Out LIB page appears. For details on storing and recalling memories, see “General Library Operation” on page 74. The Output Patch preset memory #0 contains the following...
Page 77
Using Libraries77 01V96i—Reference Manual LibrariesFor details on storing and recalling programs, see “General Library Operation” on page 74. The following tables list the preset effects programs in the Effects library: •Reverbs •Delays • Modulation-based Effects •Guitar Effects •Dynamic Effects No. Preset Name Type Description 1Reverb HallREVERB HALL Concert hall reverberation simulation with gate 2Reverb RoomREVERB ROOM Room reverberation simulation with gate 3Reverb StageREVERB STAGE Reverb designed...
Page 78
78Libraries 01V96i—Reference Manual • Combination Effects •Others • Add-On Effects No. Preset Name Type Description 29Rev+ChorusREV+CHORUS Reverb and chorus in parallel 30Rev->ChorusREV->CHORUS Reverb and chorus in series 31Rev+FlangeREV+FLANGE Reverb and flanger in parallel 32Rev->FlangeREV->FLANGE Reverb and flanger in series 33Rev+Sympho.REV+SYMPHO. Reverb and symphonic in parallel 34Rev->Sympho.REV->SYMPHO. Reverb and symphonic in series 35Rev->PanREV->PAN Reverb and auto-pan in series...
Page 79
Using Libraries79 01V96i—Reference Manual LibrariesGate Library The Gate library enables you to store and recall Input Channel gate settings. The library contains four preset memories and 124 user (readable & writable) memories. Follow the steps below to use the Gate library. 1.Press the DISPLAY ACCESS [DYNAMICS] but- ton, then press the [F2] button. The Dynamics | Gate Lib page appears. 1CURRENT TYPE This parameter displays the currently-selected channel gate type (Gate or Ducking). 2CURRENT CURVE...
Page 80
80Libraries 01V96i—Reference Manual The following table lists the preset memories in the Compressor library: No. Preset Name Type Description 1CompCOMPCompressor for reducing the overall volume level. Use it on the stereo output during mixdown, or with paired Input or Output Channels. 2ExpandEXPAND Expander template. 3Compander (H)COMPAND-H Hard-kneed compressor template. 4Compander (S)COMPAND-S Soft-kneed compressor template. 5A. Dr. BDCOMP Compressor for use with acoustic bass drum. 6A. Dr....