STARPLUS Digital Systems Technical Training . 
I. Class Schedule 
1. We start at 8:00 am and end at approximately 5:00 pm. 
2. One 15 minute break in the morning, one in the afternoon. 
3. One hour for lunch. 
II. Objective 
To introduce the student to the hardware components, system installation, and 
programming maintenance of the Starplus Digital 1428 and 2856 Key Telephone Systems. 
III.Introduce the Manual 
1. Quick Reference Table of Content 
2. List of Figures 
3. List of Tables 
4. Issue Control...

Page 522

19. Section 640 - Uniform Call Distribution (UCD) 
20. Section 750 - ICLID Programming 
21. Section 645 - Voice Mail Programming 
22. Section 650 - Exception Tables Programming 
23. Section 665 - Least Cost Routing (LCR) Programming 
24. Section 660 - Initialize Database Parameters 
25. Section 665 - Printing System Database Parameters 
26. Section 700 - System Checkout 
27. Section 800 - Maintenance and Troubleshooting 
28. Customer Database Programming Worksheets 
29. Digital Systems Part Numbers 
30....

Page 523

a. The local telephone company must notify the user of system affecting changes in 
service. 
H. Maintenance Limitations. 
a. Warranty will be voided if field repairs are attempted. 
I. Notice of Compliance. 
a. Class A Computing Device which complies with FCC part 15. 
b. Caution Statement 
1) Equipment generates RF energy. 
2) Any interference corrections are the users responsibility. 
J. Hearing Aid Compatibility. 
a. All Keysets designed to operate on the system are hearing aid compatible. 
K. OPX...

Page 524

b. Programming changes may be made from PORT 01 using a Keyset or from a I/O 
Port using a PC. 
c. Progr amming Changes may be made from On-board 300 Baud Modem. 
VI.Common Equipment for the 1428. 
1. Basic KSU with Power Supply. 
A. Wall Mountable “Flat Pack” Cabinet. 
B. Contains Key Service Board. 
a. 68000 Microprocessor. 
b. Controls all PCM/TDM circuitry. 
c. All control, switching, and interface circuitry are contained on KSB. 
C. Capable of supporting 4 CO/PBX/Centrex Lines and 8 Digital Key...

Page 525

M. CPU and Memory. 
a. Responsible for all system tones, system timing, stations status control, real time 
clock, watch dog timer and recovery, PCB status and presence/absence of modules 
for automatic software configuration setup, backup of customer database via a 
“super cap”. 
b. EPROM Memory contains system programming code. 
c. RAM Memory contains Customer Database. 
N. LEDs and Indicators: 
a. Four Green LEDs. 
1) DSl and DS5 - Presence of +12V dc to four stations each. 
2) DS2 and DS3 - Presence...

Page 526

a. Requires 117V *lOoh input voltage. 
b. Provides a filtered and regulated +12V dc and - 12V dc to the Expansion Key 
Service Board. 
c. Protected by a 1.5 Amp Slow-blo fuse. 
d. Complies with UL 1459 Second Edition. 
G. LEDs and Indicators: 
a. Four Green LEDs. 
1) DSl and DSS - Presence of +12V dc to four stations each. 
2) DS2 and DS3 - Presence of +5V dc and -5V dc. 
H. CO/Station Interfaces 
a. Four CO Interfaces 
1) RJ-11 Modular Jacks 
2) Current Sensing Circuitry for distant end disconnect (Loop...

Page 527

F. Loop Interrupt is passed to SLT ports when enabled and received from telco ( 700 
ms ). 
G. Requires Ring generator for operation. 
H. Provides Interface Circuitry for an additional DTMF Receiver module. 
5. 4x8 Expander Module. 
A. 4 CO Lines by 8 Digital Key Terminals 
B. Installs m in the Expansion KSU. 
C. Provides Interface Circuitry for an additional DTMF Receiver module. 
a. Four Green LEDs. 
1) DSl and DS2 - Presence of +12V dc to four stations each. 
2) DS3 and DS4 - Presence of +SV dc and...

Page 528

4. Central Processor Board ( CPB ) 
A. 68000 Microprocessor. 
a. Controls all PCM/TDM circuitry. 
b. All control, switching, and interface circuitry are contained on CPB. 
B. Reset Halt Switch. 
C. Contains & DTMF Receivers ( optionally provided ). 
D. Provides One RS-232C I/O Port ( RJ-45 ) 
E. Provides One Input Channel for Background Music and Music On Hold with volume 
adjustment. 
F. Provides an On-Board 300 Baud Modem. 
G. Contains additional interface connections for: 
a. Optional 1200 Baud Modem...

Page 529

F. Two RJ-14’s provide CO interface. 
a. Two CO’s per Jack. 
b. Ferrite Core Required for FCC part 15 Compliance. 
6. 4x8 SLT Interface Board 
A. 4 CO Lines by Eight 2500 Type telephones. 
B. m External Page path ( current ). 
C. Provides Interface Circuitry for an additional DTMF Receiver module. 
D. LEDs and Indicators. 
a. Five Red LEDs. 
1) Top four Indicate CO in Use. 
2) Bottom LED Indicates Relay Status. 
b. Two Green LEDs Indicate presence of +5V dc and - 5V dc. 
E. 2%Pair Amphenol Cable Provided...

Page 530

IX.Digital Terminal Description 
1. 34-Button Terminal 
A. Three Different Models 
a. 34-Button Executive Terminal has a 48 Character LCD display 
b. 34-Button Enhanced Terminal has NO display. 
c. 34-button Executive/PC Terminal has a 48 Character LCD Display and a RS-232 
Output for ICLID information interface to a Personal Computer. 
B. Digital Terminals Require Two-pair to operate. 
C. The LCD Display is Divided into Three Fields. 
a. Field One - Current Status (top line, 24 characters). 