Page 531
1) Speaker volume adjusts all voice signals sent to the speaker (i.e.. Speakerphone Conversations, Background Music, Page announcements) 2) Ring Volume adjusts all tone signals sent to the speaker. i) Muted ringing will be proportionately quieter than normal ringing based on the volume setting. G. H-T-P Switch - Three position slide switch which controls the method of receiving intercom calls. a. Hand&e (I-I) Position - Upon hearing a tone burst and voice announcement over the speaker the User...
Page 532
3) On/Off button (fixed)) 4) Mute button (fixed) 5) Speed button (fixed) 6) Flash (fixed) 7) Transfer button (fixed) 8) Hold button (fixed) C. Speakerphone Description a. Hand&x intercom two-way conversation. b. Terminate call with the On/Off button. c. Automatic Pre-selection allows the speakerphone to be enabled by pressing a button (i.e.. DSS, CO Line, Page . . . . . etc..) D. Volume controls. E. H-T-P Switch - Three position slide switch which controls the method of receiving intercom...
Page 533
: The following features are not allowed to be programmed onto DSSIDLS Console flexible buttons: ACD Agent or Supervisor Login, Do Not Disturb, Call Forward, Camp-on, Available/Unavailable, Personal Park, Voice Mail, and Headset Mode. The features may still be programmed onto the keyset fl Consoles may be associated with a station. No Duplicate Maps 1 and 2 permitted, more than one Map 3 may be associated with a station. 6. SLT Adapter / Off-Premise Extension Module A. Uses a Digital Terminal Port...
Page 534
9, PFTU - Power Fail Transfer Unit A. Provides the relay transfer circuits for up to 12 CO Lines in the event of a Power Failure. B. Controlled by a Relay Sensor Module Programmed for Power Fail Transfer. C. A customer provided 12 Volt DC Power Supply is required to operate the unit. Page 14
Page 535
System Check-Out I. Installation Check-Out List 1. Power REQUIREMENTS. A. The System requires a Dedicated Branch Circuit. a. A good definition of the circuit is the use of a constant, separately fused, dedicated only to providing power to the KSUs power supplies, 117 volt plus or minus 5%, 15 Ampere, Single Phase, 3-wire (parallel blade with ground) power outlet located within 5 feet of the KSU. KEEP THE POWER DEDICATED TO THE SYSTEM. 2. Preliminary Procedures A. Test System Ground a. Ground...
Page 536
E. After the LEDs return to their pattern, enter the programming mode either from Station 100 or via the RS232 communications port on the CPU and INITIALIZE the DATABASE (Flash 80, button 8, Hold). F. The System is now ready for programming. Page 16
Page 537
Customer Database Programming I. Introduction 1. Flexible Programming allows the system to be tailored to the customers needs. 2. No interruptions in call processing while programming the database. A. Exception is flexible port assignment. Requires a reset so system can assign time slots. 3. Methods of Programming. A. From Station 100 (port 01) using a Executive Display Terminal. a. Enter the programming mode by dialing **3226. b. The On/Off Key on the terminal is lit. c. The System is ready to...
Page 538
ii) While in programming entering a question mark (?) will return the Remote Administration Key Definitions. 4. Data Base Programming Structure and Indications A. Once the database is entered programming of attributes is facilitated using Data Field (FLASH or Program Codes) codes. a. Data Fields are used as a method of Dividing the Database into Sections of Related Attributes, much like drawers within a file cabinet. Related items are grouped together and then an individual item is changed by...
Page 539
B. Do a Flash 80, Press Flexible Button Eight (8), and Press Hold. System will initialize and reset. C. Customer Data Worksheets a. Prepare the worksheets prior to attempting programming. b. Save the sheets and update each time programming changes are made. c. Useful when programming because it contains most of the information necessary to program the entire system (Program Code, Button Map, Function, Format of Entry, Default Value). Very little supplemental information necessary to move around...
Page 540
E. Download Instructions a. b. C. d. e. E 8. h. i. i Connect an RS232-C Serial Cable from the compurter to an I/O port on the - System. Load the Procomm Plus software on the computer. Update the parameters in Procomm Plus to the settings given above. Press the EN7ER key on the computer. A prompt will display, requesting the system password be entered. Type the word VODA Ki’ and press IW7IX On the keyboard press CGA444 86 W. On the keyboard press ALT and then FI key simultaneously. This...