Home > ViewSonic > Projector > ViewSonic Pjl6233 Projector User Manual

ViewSonic Pjl6233 Projector User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual ViewSonic Pjl6233 Projector User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 617 ViewSonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							27
    Display warning dialog
    Following dialog window appears on the screen if event occurs.
    Viewing the command history
    1Click button on the tool bar. Command history window appears and the command 
    history is listed on the window as shown below.
    2To export the command history as text file (CSV file), click Export button.
    3To delete the command history, select the item of Executed date/time which you want 
    to delete, and then click Delete button. On the confirmation dialog box, click Ye s button 
    to execute deletion.
    The listed items are fixed.
    Column width can be changed by dragging the right edge of the column. The column order can be 
    changed with drag and drop the column. Column cannot be deleted.
    Up to 1000 of events can be stored. If it exceeds 1000 events, the oldest event is deleted and the 
    latest event is added. 
    Command history
    Items Description
    Executed date/time.... Executed date and time of the command
    Target name......... Name of the network equipment
    IP address............... IP address of the network equipment
    Command.............. Type of the Command
    Detailed data....... Contents of the Command
    Result........................ Results of the Command
    About event treatment 
    						
    							
    Chapter 3 Basic Operation
    Information saved to the registry 
    Following application setting information is saved to the registry of your computer. So the 
    setting condition is memorized even after quitting the application.
    Items Description
    Status window information................. Display position and size of the status list window
    Status list information............ Display status column, column width and column order
    Event log list information..... Column width and order of the event log list
    Font set up...................................... Font setting value ( Type face, size and style)
    Storing the management file
    When you monitor the network equipment with the PJ Network Manager, you can save 
    the registered target information, system setting and event log information into the man-
    agement file with a free file name. It is useful if you manage multiple equipment in the net-
    work.
    Click
    button on the tool bar and save it with free file name. The extension is ".pnm".
    The management file contains following information.
    Items Description
    Header................................................. Management file section, file version
    System default setting............. Default value of the system setting
    - Monitoring interval
    - Event reception process
    - Temperature unit
    - E-mail information
    Target information..................... Information of the registered target
    -
    Target information (target name, IP address, Community, Introduction date)- target MIB information
    - Warning value set up
    Event log information............... Event log information (ALERT, TRAP, SYSERR)
    The maximum volume of a management file is required about 1MB. (Number of registrable targets 
    is 200, number of events is 1000) 
    						
    							
    Registering the target information from the defined file at once
    The PJ Network Manager provides a function to import the target information from the 
    defined file at once. Prepare the defined file (CSV data format) in which the target informa-
    tion is written along the format shown below.
    1Select Target batch registration from System menu. The target batch registration win-
    dow appears.
    2Click Reference button and select a defined file to import the target information. The 
    imported target information will be listed on the target batch registration window.
    * If there is an error in the imported defined file, the error information will be indicated on the 
    Result column. Retry importing after correcting the defined file.
    3ClickOK button to execute the registration.
    Registering the target information from the defined file at once
    Target batch registration is not available during Target monitoring. 
    						
    							
    Chapter 3 Basic Operation
    Format of the defined file
    The defined file is a CSV data file created by the spreadsheet application and is defined as 
    follows;
    Column Description (example)
    Target name.......... Name of target equipment (Proj_01, Proj_03, PDP_01, etc.)
    IP address............... IP address (192.168.0.1, etc.)
    Community........... Name of SNMP community. Default value of our network products is "public"
    Example of the defined file
    The table below shows the example of the defined file provided with the target informa-
    tion. Save this file as the CSV file.
    Proj_01 192.168.0.1 public
    Proj_02 192.168.0.2 public
    Proj_03 192.168.0.3 public
    Proj_04 192.168.0.6 public
    Proj_05 192.168.0.7 public
    PDP_01 192.168.0.8 public
    FPD_10 192.168.0.9 public
    IP address Target nameCommunity 
    						
    							
    Login to the target equipment
    After double clicking the target name on the status list, the computer launches web 
    browser and displays the login window of the target equipment.
    You can control and set up the projector remotely by using the web browser. For the fur-
    ther information of instruction, see the separated network owner's manual.
    Login by dou-
    ble clicking
    An example of the
    login page. Login to the target equipment 
    						