    							7
    ViewSonicSNMP  Manager Software7
    7
    Chapter 3
     Basic Operation3 
    						
    							
    Chapter 3 Basic Operation
    Launching and quitting PJ Network Manager
    To launch PJ Network Manager, take one of the following.
    - Select "PJ Network Manager" from the menu "Start" - "All programs".
    - Double click a management file*
    1.
    Tool barMenu
    Status list Status barPolling times indication
    Event indication
    Items Description
    Menu..................................... Executes a command with menu selection
    Tool bar............................... Executes a command assigned to a button.
    Target................................... Network equipment for monitoring.
    Status bar........................... Indicates the status of PJ Network Manager and explaining the command selected 
    with cursor.
    Status list............................ Indicates the status of targets monitoring.
    When some errors are detected, the target name, icon and error items are indicated 
    with red.
    Status column................ Column of status list.
    Polling times indication......... Indicates the times of polling during the monitoring.
    Event indication............ Indicates the event (ALERT, TRAP, SYSERR) when the event happened.
    Name of status window
    Status column
    *1 The file in which the Monitor target information and event log information are stored. Refer to item 
    "Storing the management file" (p.28) for further details.
    * With double clicking the target name, the web browser is launching and 
    displays login window of the target.(p.31)
    Target 
    						
    							
    Quitting PJ Network Manager
    To quit the PJ Network Manager, click the close box on top right of the status window, or 
    select "Exit" from the "File" menu [Note]
    * The PJ Network Manager cannot open multiple status windows at the same time.
    Menu tree
    Menu Sub menu Operation
    File NewCreates a new management file.
    OpenOpens an existing management file.
    SaveSaves the active management file.
    Save AsSaves the active management file with a new file name.
    ExitQuits the application.
    Target Target monitoringStarts or stops target monitoring.
    Target additionAdds a new target. Target information window will appear.
    Target editingEdits selected target information.
    Target deletionDeletes the selected target.
    Group settingGroups the selected targets.
    Warning value settingSets up the warning value of the selected target.
    Telnet settingSets up the password of telnet.
    Commands batch processingSets commands batch processing for multiple selected targets.
    Timer settingSets up the timer for the selected target.
    SystemTarget batch registrationImports target information defined with the external file. 
    System default setting   Sets up the default setting (monitoring information, e-mail informa-
    tion).
    Column selectionSelects display items on the status list.
    Font settingSets up display font type and size on the status list.
    Display UpdateUpdates the information on the status list display.
    Target displayDisplays selected target information.
    Alert displayDisplays all of alert information on the status list.
    Event log displayDisplays all the event logs.
    Command history displayDisplays all of command history.
    Tool barSwitches tool bar on or off.
    Help Version informationDisplays version of software.
    What's Target
    Target indicates the network equipment which provides an SNMP agent function .
    Quitting PJ Network Manager 
    						
    							
    Chapter 3 Basic Operation
    Name of the button on the tool bar
    The following commands are assigned to the buttons on the tool bar.
    Button Operation
    New.................................................. Creates a new management file.
    Open............................................... Opens an existing management file. 
    Save................................................. Saves the active management file.
    Target monitoring................. Starts or stops target monitoring.
    Target display........................... Displays selected target information.
    Alert display............................... Displays all of alert information on the status list.
    Event log display.................... Displays all the event logs.
    Command history display.. Displays all of the command history.
    To switch the tool bar display on or off, select "Tool bar" from "Display" menu.
    NewSaveTarget displayEvent log display
    Target monitoring 
    Start/StopOpenAlert display
    Icon display for the target
    Displays icon according to the target condition.
    IconConditionFlat display type Projector type
    Normal
    Abnormal condition (One of the abnormalities, Alert, Trap or System 
    error is happening on the target.)
    Connection error ( Target has been disconnected from the network)
    Acquisition error  ( Target has been disconnected from the network, or 
    does not provide SNMP function.)
    Unknown  ( Target monitoring is not operating)
    Command history display 
    						
    							11
    Addition of the target
    1Select Target Addition from Target menu. The target 
    information registering window appears.
    2Enter target setup information and click Update button. 
    The information set on the target equipment are dis-
    played on the system information items.
    When the target equipment is not operating, or it is not the 
    monitoring equipment, the error dialog "Cannot obtain  infor-
    mation" will appear.
    3ClickOK to close the window. Repeat the above steps to register for other equipment 
    which is to be managed. 
    Editing the target
    1Select a target name to edit on the status list with right click.
    2Select Target editing on the popup menu. The target information window will appear 
    and edit the contents, then click OK button.
    The system information cannot be edited.
    Target editing can be executed by selecting Target editing from Target menu.
    Deletion of the target
    1 Select a target name to delete on the status list with right click.
    2Select Target deletion on the popup menu. The confirmation dialog will appear and 
    clickYe s button to execute deleting.
    Target deletion can be executed by selecting Target deletion from Target menu.
    It cannot perform the target addition, editing and deletion during the target monitoring.
    Up to 200 targets can be registered.
    Up to 255 characters can be used for target name and community.
    Items Description
    Name......................... Enter a management name of the target 
    equipment.
    IP address............... Enter IP address of the target equipment.
    Community........... Enter a community name in the network. 
    Default name is "public".
    System information..... Displays information set on the network 
    equipment
    Addition of the target 
    						
    							12
    Chapter 3 Basic Operation
    Setting up the warning value
    PJ Network Manager provides a function to 
    display the alert when the use time of the set-
    ting item reaches a specified setting time. The 
    available setting items (use time) are depend-
    ing on the target equipment.
    1Select a target on the status list with right click.
    When setting multiple targets together, select 
    targets with pressing "Shift" or "Control" key.
    2Select Warning value setting on the popup 
    menu. The setting window will appear as the 
    right figure.
    3CheckWarning time check box. The setting 
    items are activated. Select a setting item and click 
    Edit button. Another setting window appears.
    4Enter the threshold value of selected item and 
    then click OK button. The setting window will dis-
    appear.
    5Set up warning value for remaining items if avail-
    able and then click OK button. The setting win-
    dow will disappear.
    To disable the warning value, clear Warning time check box.
    When selecting multiple targets, the value set to the lowest target on the status list is displayed as 
    the current setting time. Up to 99,999 hours can be set for the use time. The warning value is stored 
    in the management file.
    Starting target monitoring
    1 Click button on the tool bar to start monitoring the target.
    2PJ Network Manager starts polling the target in a sequential from the top of the status 
    list and displays the results on the status list.
    (Example of the set up window) 
    						
    							
    What's Trap
    Trap is the event predefined by the SNMP agent. If the predefined event ( "When PJ lamp is 
    off ", "When internal PJ power circuit is failed" etc. ) happens, target sends trap information 
    to the SNMP manager.
    When happens the alert on the target
    When happens the alert on the target
    If the abnormality or connection error happens on the target, PJ Network Manager indi-
    cates target name, icon and status column item with red color to let you know the abnor-
    mality.
    When PJ Network Manager cannot acquire the MIB information of the target equipment, it indicates 
    as Connection Error.
    The interval of target monitoring is according to the setting of Monitoring interval on System 
    default setting from System menu. 
    (p.17)
    For the way to give notice of the alert information, refer to Event reception process on System 
    default setting from System menu. (p.17)
    When happens the trap event on the target
    During the target monitoring, if the predefined event (trap) happens on the target equip-
    ment, the target sends the trap information to PJ Network Manager. This trap information is 
    displayed on the status list.
    The trap information is set up in the SNMP setting items of the target equipment. Projector 
    has items such as "When PJ lamp is off ", "When the life span of lamp is reached", "When 
    internal PJ power circuit is failed" etc. For further trap information, refer to "SNMP setting" in 
    the separated network owner's manual.
    For the way to give notice of the trap information, refer to Event reception process on System 
    default setting from System menu. (p.17) 
    						
    							
    Chapter 3 Basic Operation
    Displaying all the status information of the target
    Select a target and click button on the tool bar. The following status window appears 
    and displays all the available status information of the target.
    The target name and item which have an 
    abnormality or connection error happen-
    ing are indicated with red.
    When PJ Network Manager cannot 
    acquire the value of column information,  
    "---"  is displayed.
    Stopping monitoring the target
    To stop monitoring the target, click  button again on the tool bar.
    The projectors setting different network passwords cannot be set to the same group. It is nec-
    essary for the projectors in the same group to set to the same password.
    The above procedure can perform by selecting Target display from Display menu.
    Setting the target group
    The target group can be set up by the procedure below. When you set a command in the 
    same group, you set it.
    1Select targets which you want to set from the status list. Select Group setting from 
    Target menu, the dialog box will appear as the below figure.
    2Select a group, and then click OK button.
    "---" will not set the group. 
    						
    							15
    Setting up the password of Telnet
    The password of telnet can be set up by the procedure below. It is necessary to make a 
    password, same as the network password.
    1Select a target which you want to set up the password of telnet from the status list. You 
    can select multiple targets.
    2Select Telnet setting from Target menu, Telnet setting dialog box will appear as the 
    below figure. Set a password and click OK button. When multiple targets are selected, all 
    the selected targets are set as the same password.
    Setting up the password of Telnet
    The initial setting is "0000".
    Setting commands batch processing for multiple targets
    The commands batch processing for multiple targets can be set up by the procedure 
    below.
    1Select a target belonging to the batch processing group which you want to set, and 
    select Commands batch processing from Target menu. Commands batch processing
    dialog box will appear as the below figure.
    2Select a command which you want to set, click Edit button. Parameter editing dia-
    log box will appear. Select a parameter, and then click OK button. The check box of 
    Commands batch processing dialog box will be checked.
    3ClickOK button. The commands are carried out to all the targets of the same group.
    The commands also work for the target which is not set to a group. 
    						
    							
    Chapter 3 Basic Operation
    Commands batch processing : Available CommandItems Description
    Power ON/OFF.........................Sets up the Power ON or Power OFF.
    Input,Source
    ..............................Sets up the Input and Source. Selects Input and Source.
    Screen.......................................Sets up the screen size. Resizes the picture screen.
    Background
    ...............................Sets up the background. Selects the background screen for when no input signal is 
    detected.
    Display
    ........................................Sets up the Display. Decides whether to display On-Screen Displays or not.
    Shutter(No show)....................Sets up the Shutter (No show). Sets black out the image.
    Lamp control.............................Sets up the Lamp control. Changes brightness of the screen.
    Fan control.................................Sets up the Fan control. Chooses the running speed of cooling fans.
    Setting timer for targets
    The timer information for targets can be set up by the procedure below.
    1Choose a target which you want to set the timer.
    2Select Timer setting from Target menu. Timer selection dialog box will appear as the 
    below figure. Check in a check box of an event to carry out.
    3When you want to add events,clickAdd button. Input timer informations in Timer set-
    ting dialog box, and click OK button.
    4Click OK button of Timer selection dialog box, timers are set to the selected target. 
    When selecting multiple targets, timers are set to all the selected targets.
    TimerItems Description
    Execution date.........................Sets up the Timer execution date.  (everyday or a day)
    Execution time
    ..........................Sets up the Timer execution time. (hh:mm:ss)
    Action.......................................Sets up the events. 
    						