Page 141
INSTALLATION-PCB SECTION 200-096-206 FEBRUARY1991 J2 CRCU (-4 or -8) \! ! J3 P9 P8 ROM (4 each) Located under CRCU J4 FlGURE6-3-DTMF RECEIVER UNlT(CRCU)lNSTALLATlON with PCTU connectors P2, P3, P8, and P9 (refer to Figure 6-3). 3) Apply firm, even pressure to CRCU to ensure proper mating of connectors. 3.20 PCTU Installation Procedures 3.21 Install the PCTU in accordance with the fol- lowing steps: CAUTION! Do not remove plastic insulating shield from back of PCTU PCB. If shield...
Page 142
INSTALLATION-PCB SECTION 200-096-206 FEBRUARY 1991 outward. If the connectors are properly mated, a slight resistance will be felt. NOTES: 1. Do not adjust trimmer capacitor C4. The capacitor is factory-calibrated. 2. When transporting the PCTU, keep the P7 battery strap in the ON position if it is de- sired to save the configuration data stored in PCTU RAM (the battery will protect RAM for approximately six years); other- wise, to conserve the lithium battery, move P7 to the OFF position....
Page 143
INSTALLATION-PCB SECTION 200-096-206 FEBRUARY1991 W5, cut for y BGM option W9, cut for - HDCB option 50-PIN AMPHENOL CONNECTOR (FEMALE) /- BACKPLANE CONNECTOR FlGURE6-4-PEKUCONTROLSANDlNTERFACECONNECTORS NOTE: Refer to Telephone Installation, Sections200- 096-207 and 200-096-208, for installation of external options. 4.12 Off-hook Call Announce (EOCU) Instal- lation. Install the Off-hook Call Announce Unit (EOCU) in accordance with the following steps: 1) Remove the PCB from its...
Page 144
INSTALLATION-PCB SECTION 200-096-206 FEBRUARY 1991 TABLE 6-B PEKU CONTROLS AND INTERFACE CONNECTORS CONTROL/INDICATOR/ CONNECTOR (Figure 6-4) TYPE OF COMPONENT DESCRIPTION Off-hook Call Announce PlO 1 O-pin connector Interface connector for optional Off-hook Call Announce subassembly connector (used in conjunction with P20, P40, P50, and P60). Off-hook Call Announce P20 1 O-pin connector Off-hook Call Announce P40 1 O-pin connector Off-hook Call Announce P50 1 O-pin connector Interface...
Page 145
the W9 Door Phone jumper wire on the PEKU PCB. 3) Refer to Telephone Installation, Section 200- 096-207, for installation procedures for the HDCB, control box and associated door phones (MDFBs). 4) Each HDCB requires dedicated use of circuit 5 of a particular PEKU PCB. 4.15 Background Music Configuration. Config- ure the PEKU to support a background music source in accordance with the following steps: 1) Remove the PCB from its protective packag- ing. 2) Cut the W5 (BGM) jumper wire on the...
Page 146
INSTALLATION-PCB SECTION 200-096-206 FEBRUARY1991 SSTU SUBUNIT 50-PIN AMPHENOL CONNECTOR (FEMALE) Wl Ring Voltage t H = 19OV F-P I h I 1: II , L=13OVP-P I I /C^.. me-r, I 111 1, ul r3 I u v.4) and PSTU2 only) 0, BACKPLANE CONNECTOR HtiUKt ti-ti-t’S I U (l/Z) ANU SUWNI I (SS I U) must be installed on the Common Control Unit (PCTU) (refer to Paragraph 3). 5.02 PSTU controls are shown in Figure 6-6 and described in Table 6-C. P or 19OV P-P. The Wl jumper plug is used to set the voltage...
Page 147
l Wl set to L (13OV P-P). l Two ringers maximum per port (H or L). 5.20 PSTU Installation Procedures 5.21 Install the PSTU in accordance with the fol- lowing steps: 1) Remove the PCB from its protective packag- ing. The protective shield on the back of the PSTU is designed to protect the installer from potentially hazardous ring voltage. Do not remove this shield. 2) Ensure that the PSTU subunit (SSTU) is se- curely attached to the PSTU (refer to Figure 6- 6). NOTE: Wl, the ring generator...
Page 148
INSTALLATION-PM SECTION 200-096-206 FEBRUARY1991 50-PIN AMPHENOL CONNECTOR (FEMALE) / CUT W7 ONLY IF BGM IS CONNECTED TO PORT 07, CIRCUIT 8, SLOT 01. OPTIONAL EOCU, EQUIP FOR OCA FEATURE v ,‘i iw iw &G&-i ,~~~ I ___-_---_--_____--____________ $, CUT W9 FOR DOOR PHONE OPTION (HDCB ON CIRCUIT 5) Illk I ;j BACKPLANE I j P80 CONNECTOR : ; I ; ___ 0 0 UP g P90 PESU 3ING VOLTAGE OPTION (PORTS 1 & 2): ESTS: STANDARD TELEPHONE - = LOW LEVEL (13OV P-P) INTERFACE, ALWAYS EQUIPPED...
Page 149
INSTALLATION-PCB SECTION 200-096-206 FEBRUARY1991 TABLE6-D PESUCONTROLSANDINTERFACECONNECTORS I I . CONTROL/INDICATOR/ CONNECTOR (Figure 6-7) TYPE OF COMPONENT DESCRIPTION Off-hook Call Announce PlO 1 O-pin connector Interface connector for optional Off-hook Call Announce subassembly connector (used in conjunction with P20, P40. P50. and P60). Off-hook Call Announce P20 Off-hook Call Announce P40 Off-hook Call Announce P50 Off-hook Call Announce P60 1 O-pin connector 1 O-pin...
Page 150
INSTALLATION-PCB SECTION 200-096-206 FEBRUARY 1991 2) 3) 4) 5) Mate the EOCU connectors JIO, 520, J40, J50, and J60 with the PESU connectors PI 0, P20, P40, P50, and P60 (refer to Figure 6-7). Apply firm, even pressure to the EOCU to ensure proper mating of connectors. Use 3-pair cable for connecting the PESU and the OCA electronic telephone (refer to Wiring Diagrams, Section 200-096-209, for wiring/ interconnecting details). Refer to Telephone Installation, Section 200- 096-207, for...