INSTALLATION-PCB 
SECTION 200-096-206 
FEBRUARY1991 
J2 
CRCU (-4 or -8) 
\! ! J3 
 P9 
P8 
ROM (4 each) 
Located under CRCU J4 
FlGURE6-3-DTMF RECEIVER UNlT(CRCU)lNSTALLATlON 
with PCTU connectors P2, P3, P8, and P9 
(refer to Figure 6-3). 
3) Apply firm, even pressure to CRCU to ensure 
proper mating of connectors. 
3.20 PCTU Installation Procedures 
3.21 
Install the PCTU in accordance with the fol- 
lowing steps: 
CAUTION! 
Do 
not remove plastic insulating shield 
from back of PCTU PCB. If shield...

Page 142

INSTALLATION-PCB 
SECTION 200-096-206 
FEBRUARY 1991 
outward. If the connectors are properly mated, 
a slight resistance will be felt. 
NOTES: 
1. Do not adjust trimmer capacitor C4. The 
capacitor is factory-calibrated. 
2. When transporting the PCTU, keep the P7 
battery strap in the ON position if it is de- 
sired to save the configuration data stored 
in PCTU RAM (the battery will protect 
RAM for approximately six years); other- 
wise, to conserve the lithium battery, move 
P7 to the OFF position....

Page 143

INSTALLATION-PCB 
SECTION 200-096-206 
FEBRUARY1991 
W5, cut for y 
BGM 
option 
W9, cut for - 
HDCB option 
50-PIN AMPHENOL CONNECTOR (FEMALE) 
/- 
BACKPLANE CONNECTOR 
FlGURE6-4-PEKUCONTROLSANDlNTERFACECONNECTORS 
NOTE: 
Refer to Telephone Installation, Sections200- 
096-207 and 200-096-208, for installation of 
external options. 
4.12 Off-hook Call Announce (EOCU) Instal- 
lation. 
Install the Off-hook Call Announce Unit 
(EOCU) in accordance with the following steps: 
1) Remove the PCB from its...

Page 144

INSTALLATION-PCB 
SECTION 200-096-206 
FEBRUARY 1991 
TABLE 6-B 
PEKU CONTROLS AND INTERFACE CONNECTORS 
CONTROL/INDICATOR/ 
CONNECTOR (Figure 6-4) TYPE OF COMPONENT DESCRIPTION 
Off-hook Call 
Announce PlO 1 O-pin connector Interface connector for optional Off-hook 
Call Announce subassembly 
connector (used in conjunction with P20, 
P40, P50, and P60). 
Off-hook Call 
Announce P20 1 O-pin connector 
Off-hook Call 
Announce P40 1 O-pin connector 
Off-hook Call 
Announce P50 1 O-pin connector Interface...

Page 145

the W9 Door Phone jumper wire on the PEKU 
PCB. 
3) Refer to Telephone Installation, Section 200- 
096-207, for installation procedures for the 
HDCB, control box and associated door 
phones (MDFBs). 
4) Each HDCB requires dedicated use of circuit 
5 of a particular PEKU PCB. 
4.15 Background Music Configuration. Config- 
ure the PEKU to support a background music 
source in accordance with the following steps: 
1) Remove the PCB from its protective packag- 
ing. 
2) Cut the 
W5 (BGM) jumper wire on the...

Page 146

INSTALLATION-PCB 
SECTION 200-096-206 
FEBRUARY1991 
SSTU 
SUBUNIT 50-PIN AMPHENOL CONNECTOR (FEMALE) Wl Ring Voltage 
t  H = 19OV F-P 
I h I 
1: II , L=13OVP-P 
I I /C^.. me-r, I 111 1, 

ul r3 I u  v.4) 
and PSTU2 only) 
0, 
BACKPLANE CONNECTOR 
HtiUKt ti-ti-t’S I U (l/Z) ANU SUWNI I (SS I U) 
must be installed on the Common Control Unit 
(PCTU) (refer to Paragraph 3). 
5.02 PSTU controls are shown in Figure 6-6 and 
described in Table 6-C. P or 19OV P-P. The Wl jumper plug is used to set 
the voltage...

Page 147

l Wl set to L (13OV P-P). 
l Two ringers maximum per port (H or L). 
5.20 PSTU Installation Procedures 
5.21 
Install the PSTU in accordance with the fol- 
lowing steps: 
1) Remove the PCB from its protective packag- 
ing. The protective shield on the back of the 
PSTU is designed to protect the installer from 
potentially hazardous ring voltage. Do not 
remove this shield. 
2) Ensure that the PSTU subunit (SSTU) is se- 
curely attached to the PSTU (refer to Figure 6- 
6). 
NOTE: 
Wl, the ring generator...

Page 148

INSTALLATION-PM 
SECTION 200-096-206 
FEBRUARY1991 
50-PIN 
AMPHENOL 
CONNECTOR 
(FEMALE) / CUT W7 ONLY IF BGM IS CONNECTED TO 
PORT 07, CIRCUIT 8, SLOT 01. 
OPTIONAL 
EOCU, EQUIP 
FOR OCA 
FEATURE 
v ,‘i 
iw 
iw &G&-i 
,~~~ I ___-_---_--_____--____________ $, 
CUT W9 FOR 
DOOR PHONE 
OPTION (HDCB 
ON CIRCUIT 5) 
Illk I ;j BACKPLANE 
I j P80 
CONNECTOR 
: ; 
I ; 
___ 
0 
0 
UP 
g 
P90 
PESU 
3ING VOLTAGE OPTION (PORTS 1 & 2): ESTS: STANDARD TELEPHONE 
- = LOW LEVEL (13OV P-P) INTERFACE, ALWAYS EQUIPPED...

Page 149

INSTALLATION-PCB 
SECTION 200-096-206 
FEBRUARY1991 
TABLE6-D 
PESUCONTROLSANDINTERFACECONNECTORS 
I I . 
CONTROL/INDICATOR/ 
CONNECTOR (Figure 6-7) TYPE OF COMPONENT DESCRIPTION 
Off-hook Call 
Announce PlO 1 O-pin connector Interface connector for optional Off-hook 
Call Announce subassembly 
connector (used in conjunction with P20, 
P40. P50. and P60). 
Off-hook Call 
Announce P20 
Off-hook Call 
Announce P40 
Off-hook Call 
Announce P50 
Off-hook Call 
Announce P60 1 O-pin connector 
1 O-pin...

Page 150

INSTALLATION-PCB 
SECTION 200-096-206 
FEBRUARY 1991 
2) 
3) 
4) 
5) Mate the EOCU connectors 
JIO, 520, J40, J50, 
and J60 with the PESU connectors PI 0, P20, 
P40, P50, 
and P60 (refer to Figure 6-7). 
Apply firm, even pressure to the EOCU to 
ensure proper mating of connectors. 
Use 3-pair cable for connecting the PESU and 
the OCA electronic telephone (refer to Wiring 
Diagrams, Section 200-096-209, for wiring/ 
interconnecting details). 
Refer to Telephone Installation, Section 200- 
096-207, for...