Page 191
INSTALLATION-PERIPHERALS SECTION 200-096-208 FEBRUARY 1991 11) Plug the provided power cord into the power supply and to a 117 VAC, 60Hz power source. 5.26 Talkback Amplified Speaker Test. Test the Talkback Amplified Speaker installation in accor- dance with the following steps: 1) Make an external page. l Page will be heard over the HESB. 2) Verify that someone speaking into the door phone can be heard at the paging station (with this application, pressing the door phone but- ton is not...
Page 192
contact’s PIOU relays Kl - K4 and the “C” terminal of zone 1 - zone 4 speakers. 4) Connect the BGM music amplifier output to terminal 23 (PG COMMON) of the PIOU, and to zone 1 - zone 4 speakers. 6.15 Zone Page with BGM (multiple amplifiers). This configuration also provides multiple-zone paging capability, as in Paragraph 6.13. However, separate amplifiers are used for each zone. Install this option in accordance with the following steps (refer to Figure 8-l 6): 1) 2) 3) 4) 5) Connect the...
Page 193
INSTALLATION-PERIPHERALS SECTION 200-096-208 FEBRUARY1991 l MODM: Prints on calls to the IMDU remote maintenance modem (station 19). l DISA: Prints on DISA calls to CO lines when calling through the system CO-to-CO. NOTE: MSS willprintonlyon DISA orDlSCcalls thatare answered 10 seconds after the DK dial tone is sent to the calling party. If the call is answered before 10 seconds, the call will register as a normal incoming call and the MSS/transfer portion of the call will not print out....
Page 194
7.03 System Program Data Printout. If a printer is connected to the SMDR port, customer program information stored in the PCTU or PCTUSI RAM may be printed out for reference by using Program 97 (see Paragraph 7.14). 7.10 SMDR Hardware Requirements 7.11 A DK system must be equipped with a PIOU or PIOUS PC6 to support the SMDR printer/call accounting device option. Connection of the printer or call accounting device to the PIOU or PIOUS PCB is accomplished with a 3-pair modular cord (7 feet...
Page 195
INSTALLATION-PERIPHERALS SECTION 200-096-208 FEBRUARY1991 nance modem to the PIOU or PIOUS PCB is accomplished with a standard 3-pair modular cord and a PPTC adaptor connected to the PIOU or PIOUS TTY jack (refer to Figure 8-21). NOTE: If the IMDUmodem is used, the PPTC adapter or modular cord is not required. 8.20 Local Maintenance Terminal Installation 8.21 Install the ASCII terminal in accordance with the following steps (refer to Figure 8-21): 1) Connect the 3-pair modular cable (or 24...
Page 196
NOTE: The P13 (PIOU) or W4 (PIOUS) CCITT con- figurations are not normally used in the USA. 6) Programming and system testing, via the exter- nal maintenance modem, is described in the Remote Maintenance Procedures, Section 200- 096-400. Access to the external maintenance modem is accomplished as follows: If the modem is connected to adedicated CO line, call the CO line number to estab- lish modem communication. If the modem is connected to a PSTU or PESU port, call a DK CO line that can be...
Page 197
INSTALLATION-PERIPHERALS SECTION 200-096-208 FEBRUARY1991 messaging systems. Depending on the voice mail system used, some of the features available with INTOUCH (refer to Paragraph 9.10) may be avail- able with the customer-supplied system. 9.22 Voice Mail (PSTU or PESU Port) Program- ming Considerations 9.23 Voice mail (all types) PSTU or PESU port programming is accomplished using Programs 31 and IO-2 (refer to Programming Procedures, Sec- tion 200-096-300, for details). Voice mail (VM)...
Page 198
to a hunting sequence, starting with the Iow- est port hunting to the next highest port, etc. The last hunt should be to an attendant. l Program 35: LEDs 01 and 02 must be ON for stations to receive the message indica- tion (MW LED flashing) from a VM device. l Program 36: Set fixed call forward to VM/ AA port per customer requirements. l Program 37: Set the timer for the VM/AA ports to 22 seconds minimum to allow call forward no answer to work on VM transferred calls. l Program 39: Set the...
Page 199
INSTALLATION-PERIPHERALS SECTION 200-096-208 FEBRUARY1991 PPSU 24/56/96 + BATT : - TWO-PRONG MALE CONNECTOR (PRE-ASSEMBLED) PBTC-3M BATTERYCABLE WITH RING TERMINALS AND PPSU CONNECTOR (LENGTH 9 FEET) IN-LINE FUSE HOLDER IOA (FUSE PROVIDED) WHITE POWER SUPPLY 16AWG - + - + ACTUAL SIZE 12VDC BATTERY RING TERMINALS 3/8 IN. BLACK JUMPER WITH RING TERMINALS (PROVIDED) FlGURE8-I-RESERVE POWER/BATTERYWlRlNG 8-18
Page 200
INSTALLATION-PERIPHERALS SECTION 200-096-208 FEBRUARY1991 I TO PSTU3-Ti ; > J2-27 ’ J2-2 TO PSTU3-RI I> I I I I I I I I TO PCOU-Tl 14 Ji-27 I ’ Ji-2 TO PCOU-RI ) 4 I I I J2-26 < ‘TO TEL-T1 J2-1 ’ < 1 TO TEL-RI I I I I TELEPHONE I I I CURRENT DETECTOR 1 I I -z c+.Y - I I I l J.c a Ji-26 - + IT0 CO-T1 I I l p = Jl-1 ’ * (TO CO-RI I I I i DG PSTU CONTROL ! -24V (INPUT) ; 4 Ji-50 I I I I I I I I I I (INPUT) ; RELAY Ji-25 NOTES: 1....