Home > Toshiba > Communications System > Toshiba Strata Dk24, Dk56, Dk96 Instruction Manual

Toshiba Strata Dk24, Dk56, Dk96 Instruction Manual

Here you can view all the pages of manual Toshiba Strata Dk24, Dk56, Dk96 Instruction Manual. The Toshiba manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 191

INSTALLATION-PERIPHERALS 
SECTION 200-096-208 
FEBRUARY 1991 
11) Plug the provided power cord into the power 
supply and to a 117 VAC, 60Hz power source. 
5.26 Talkback Amplified Speaker Test. Test the 
Talkback Amplified Speaker installation in accor- 
dance with the following steps: 
1) Make an external page. 
l Page will be heard over the HESB. 
2) Verify that someone speaking into the door 
phone can be heard at the paging station (with 
this application, pressing the door phone but- 
ton is not...

Page 192

contact’s PIOU relays Kl - K4 and the “C” 
terminal of zone 1 - zone 4 speakers. 
4) Connect the BGM music amplifier output to 
terminal 23 (PG COMMON) of the PIOU, and 
to zone 1 - zone 4 speakers. 
6.15 Zone Page with BGM (multiple amplifiers). 
This configuration also provides multiple-zone 
paging capability, as in Paragraph 6.13. However, 
separate amplifiers are used for each zone. Install 
this option in accordance with the following steps 
(refer to Figure 8-l 6): 
1) 
2) 
3) 
4) 
5) 
Connect the...

Page 193

INSTALLATION-PERIPHERALS 
SECTION 200-096-208 
FEBRUARY1991 
l MODM: Prints on calls to the IMDU remote 
maintenance modem (station 19). 
l DISA: Prints on DISA calls to CO lines when 
calling through the system CO-to-CO. 
NOTE: 
MSS willprintonlyon DISA orDlSCcalls thatare 
answered 10 seconds after the DK dial tone is 
sent to the calling party. If the call is answered 
before 10 seconds, the call will register as a 
normal incoming call and the MSS/transfer 
portion of the call will not print out....

Page 194

7.03 System Program Data Printout. If a printer 
is connected to the SMDR port, customer program 
information stored in the PCTU or PCTUSI RAM 
may be printed out for reference by using 
Program 
97 (see Paragraph 7.14). 
7.10 SMDR Hardware Requirements 
7.11 
A DK system must be equipped with a PIOU 
or PIOUS PC6 to support the SMDR printer/call 
accounting device option. Connection of the printer 
or call accounting device to the PIOU or PIOUS 
PCB is accomplished with a 3-pair modular cord (7 
feet...

Page 195

INSTALLATION-PERIPHERALS 
SECTION 200-096-208 
FEBRUARY1991 
nance modem to the PIOU or PIOUS PCB is 
accomplished with a standard 3-pair modular cord 
and a PPTC adaptor connected to the PIOU or 
PIOUS TTY jack (refer to Figure 8-21). 
NOTE: 
If the IMDUmodem is used, the PPTC adapter 
or modular cord is not required. 
8.20 Local Maintenance Terminal Installation 
8.21 Install the ASCII terminal in accordance with 
the following steps (refer to Figure 8-21): 
1) Connect the 3-pair modular cable (or 24...

Page 196

NOTE: 
The P13 (PIOU) or W4 (PIOUS) CCITT con- 
figurations are not normally used in the USA. 
6) Programming and system testing, via the exter- 
nal maintenance modem, is described in the 
Remote Maintenance Procedures, Section 200- 
096-400. Access to the external maintenance 
modem is accomplished as follows: 
If the modem is connected to adedicated 
CO line, call the CO line number to estab- 
lish modem communication. 
If the modem is connected to a PSTU or 
PESU port, call a DK CO line that can be...

Page 197

INSTALLATION-PERIPHERALS 
SECTION 200-096-208 
FEBRUARY1991 
messaging systems. Depending on the voice mail 
system used, some of the features available with 
INTOUCH (refer to Paragraph 
9.10) may be avail- 
able with the customer-supplied system. 
9.22 Voice Mail (PSTU or PESU Port) Program- 
ming Considerations 
9.23 Voice mail (all types) PSTU or PESU port 
programming is accomplished using 
Programs 31 
and IO-2 (refer to Programming Procedures, Sec- 
tion 200-096-300, for details). Voice mail (VM)...

Page 198

to a hunting sequence, starting with the Iow- 
est port hunting to the next highest port, etc. 
The last hunt should be to an attendant. 
l Program 35: LEDs 01 and 02 must be ON 
for stations to receive the message indica- 
tion (MW LED flashing) from a VM device. 
l Program 36: Set fixed call forward to VM/ 
AA port per customer requirements. 
l Program 37: Set the timer for the VM/AA 
ports to 22 seconds minimum to allow call 
forward no answer to work on VM transferred 
calls. 
l Program 39: Set the...

Page 199

INSTALLATION-PERIPHERALS 
SECTION 200-096-208 
FEBRUARY1991 
PPSU 
24/56/96 
+ 
BATT : 
- TWO-PRONG 
MALE CONNECTOR 
(PRE-ASSEMBLED) 
PBTC-3M 
BATTERYCABLE 
WITH RING TERMINALS 
AND PPSU CONNECTOR 
(LENGTH 9 FEET) 
IN-LINE 
FUSE HOLDER 
IOA 
(FUSE PROVIDED) 
WHITE 
POWER SUPPLY 
16AWG 
- 
+ - 
+ 
ACTUAL 
SIZE 
 12VDC 
BATTERY 
RING TERMINALS 3/8 IN. BLACK JUMPER 
WITH RING TERMINALS 
(PROVIDED) 
FlGURE8-I-RESERVE POWER/BATTERYWlRlNG 
8-18  

Page 200

INSTALLATION-PERIPHERALS 
SECTION 200-096-208 
FEBRUARY1991 
I 
TO PSTU3-Ti ; > J2-27 
’ J2-2 
TO PSTU3-RI I> 
I 
I 
I 
I 
I 
I 
I 
I 
TO PCOU-Tl 14 Ji-27 
I 
’ Ji-2 
TO PCOU-RI ) 4 
I 
I I 
J2-26 
< ‘TO TEL-T1 
J2-1 ’ 
< 1 TO TEL-RI 
I 
I 
I 
I 
TELEPHONE I 
I 
I 
CURRENT DETECTOR 1 I 
I -z c+.Y - 
I 
I 
I 
l J.c a Ji-26 
- + IT0 CO-T1 
I 
I 
l p = Jl-1 ’ 
* (TO CO-RI 
I 
I 
I 
i 
DG 
PSTU 
CONTROL 
! -24V (INPUT) ; 
4 Ji-50 
I 
I 
I 
I 
I 
I 
I 
I 
I 
I 
(INPUT) ; RELAY 
Ji-25 
NOTES: 
1....