Page 161

INSTALLATION-PCB 
SECTION 200-096-206 
FEBRUARY 1991 
TABLE 6-l 
PEPU CONTROLS AND INTERFACE CONNECTORS . 
CONTROL/INDICATOR/ 
CONNECTOR 
(Figure 6-13) 
. - 
M/B Make/Break 
Jumper Plug PI0 
TYPE OF COMPONENT DESCRIPTION 
Three-terminal jumper plug External Page/Door Lock Control Relay 
MAKE or BREAK jumper plug. 
I 
M/B Make/Break 
Jumper Plug PI 1 Three-terminal jumper plug Night/Hold Relay MAKE or BREAK jumper 
plug. 
Two-position slide switch Selects built-in 3-watt amplifier or 
600-ohm output for...

Page 162

INSTALLATION-PCB 
SECTION 200-096-206 
FEBRUARY 1991 
12 PCB INSTALLATION OVERVIEW 
(RELEASE 3) 
12.01 
PCBslot installation considerationsdiscussed 
in Paragraph 2 are the same with 
Release 3, except 
for one change: with 
Release 3, the PDKU PCB or 
the PEKU PCB should be installed in slot I-previ- 
ously only the PEKU was recommended. It does not 
matter whether it’s the PEKU or the PDKU installed 
in slot 1. However, it is recommended that they be the 
first PCBs installed from left to right. 
13...

Page 163

console requires dedicated use of circuit 8 of a 
particular PDKU PCB. 
13.14 PDIU-DS Configuration. Refer to Periph- 
erals Installation, Chapter 8, for installation proce- 
dures for the PDIU-DS. A PDIU-DS can be con- 
nected to circuits 1 N 7 on a PDKU; the circuit must 
be dedicated to the PDIU-DS. 
13.15 PDIU-DI Configuration. Refer to Telephone 
Installation, Chapter 7, and Peripherals Installation, 
Chapter 8, for installation procedures for the PDIU- 
DI. PDIU-Dls can be equipped with any digital...

Page 164

INSTALLATION-PCB 
SECTION 200-096-206 
FEBRUARY 1991 
P7, shown in / 
OFF 
position 
LITHIUM / 
BATTERY 
BACKPLANE HEARTBEAT LED P2 
P3 
00 VERSION 
FIGURE 6-15-PCTU3 CONTROLS, INDICATORS, AND INTERFACE CONNECTOR 
PSTUs as PCTUl and PCTU2. It also supports the 
same hardware options and has the same pro- 
gramming parameters. 19 PEMU (RELEASE 3) 
17 PESU (RELEASE 3) 
17.00 For PESU installation instructions, see 
Paragraph 6. PCTU3 supports the same number 
of PESUs as PCTUI and PCTU2. It also supports...

Page 165

TOSHIBASYSTEMPRACTICES 
DIGITALKEYTELEPHONESYSTEMS INSTALLATION-TELEPHONE 
SECTION 200-096-207 
FEBRUARY1991 
Stra ta7mx 
RELEASE 1,2, and 3 
INSTALLATION 
CHAPTER SEVEN 
TELEPHONE INSTALLATION  

Page 166

INSTALLATION-TELEPHONE 
SECTION 200-096-207 
FEBRUARY1991 
TABLEOFCONTENTS 
SUBJECT 
. PAGE 
GENERAL ................................................................................................................. 7-l 
ELECTRONIC TELEPHONE UPGRADE OPTIONS ................................................ 7-l 
Electronic Telephone Upgrade Installation.. 
.......................................................... 7-l 
Carbon Handset Option.....

Page 167

INSTALLATION-TELEPHONE 
SECTION 200-096-207 
FEBRUARY 1991 
1 GENERAL 
1.00 
This chapter provides the general instruc- 
tions to connect electronic telephones, digital 
telephones, standard telephones (including door 
phones and door locks), and DSSDDSS consoles 
to DK systems. 
1.01 The chapter also includes procedures to 
upgrade electronic and digital telephones for Loud 
Ringing Bell/Headset Interface and Off-hook Call 
Announce capability, and to wall-mount electronic 
and digital telephones. 
2...

Page 168

INSTALLATION-TELEPHONE 
SECTION 200-096-207 
FEBRUARY1991 
COMPONENT SIDE OF HHEU FEED THROUGH 
TO HESB 
FOR HESC-65 CABLE 
HESC-65A CABLE 
HHEU P601 
FlGURE7-2-HHEUINSTALLATION FIGURE 7-4-HESC-65 CABLING 
HKT6520KSD 
CONNECTOR 5) Position the HHEU PCB on the standoffs 
inside the base (Figure 7-2), and secure with 
the two screws provided. 
6) Connect the HHEU PCB to the electronic 
telephone PCB as shown in Figure 7-3. 
7) Cut HHEU strap shown in Figure 7-3. 
NOTE: 
HHEU strap must be replaced if the...

Page 169

INSTALLATION-TELEPHONE 
SECTION 200-096-207 
FEBRUARY 1991 
PCB is aligned with the silk-screened image 
on the HVSI PCB. 
2) Align the 
P5 connector on the HVSI PCB with 
its receptacle on the HVSU PCB (Figure 7-5). 
Apply firm, even pressure to the PCBs to 
ensure that the connectors mate properly 
(they click). 
3) Position the HVSU/HVSI assembly on the 
standoffs inside the base, and secure with the 
two screws provided. 
4) Connect the HVSU/HVSI PCBs to the elec- 
tronic telephone PCB as shown in...

Page 170

INSTALLATION-TELEPHONE 
SECTION 200-096-207 
FEBRUARY1991 
telephones, standard telephones, DSS consoles, 
and door phones/locks to STRATA DK systems. 
The following paragraphs provide general require- 
ments for telephone installation. 
3.01 Refer to the Programming Procedures, Sec- 
tion 200-096-300, for programming requirements 
and procedures. 
3.10 Electronic Telephone Connections 
3.11 
Electronic telephones are connected to the 
PEKU or PESU PCB (via the MDF) with standard 
twisted-pair jacketed...