Page 91

INSTALLATION-SITE REQUIREMENTS 
SECTION 200-096-203 
FEBRUARY1991 
TABLE34 
SUMMARY 
OFELECTRICAL/ENVIRONMENTALCHARACTERlSTlCS . 
GENERAL 
Primary Power 
Input AC 
AC Frequency 
DK24 power supply 
DK56 power supply 
DK96 power supply 
85VAC - 135VAC 
50/60 Hz 
65 watts 
140 watts 
230 watts 
I 
Environmental Specifications 
Operating Temperature 
Operating Humidity 
Storage Temperature 
32 - 104°F (0 * 40°C) 
20 * 80% relative humidity (without condensation) 
-4 - 158°F (-20 * 70°C) 
Power Supply 
DC...

Page 92

6 SITE CONSIDERATIONS (continued) 
6.00 The following precautions should be adhered 
to when installing telephone wiring: GROUND 1; THIRD WIRE GRO;ND 
 TO AC POWER CORD 
WARNING! 
1. Never install the telephone wiring dur- 
ing a lightning storm. 
2. Never install the telephone jacks in wet 
locations unless the jack is specifically 
designed for wet locations. 
3. Never touch uninsulated telephone 
wires or terminals unless the telephone 
line has been disconnected at the net- 
work interface. 
4. Use...

Page 93

INSTALLATION-SITE REQUIREMENTS 
SECTION 200-096-203 
FEBRUARY1991 
? 
I’ 
This page intentionally left blank 
3-6  

Page 94

TOSHIBASYSTEM PRACTICES 
DIGITALKEYTELEPHONESYSTEMS INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY1991 
Stra taExx 
RELEASE 1,2, and 3 
INSTALLATION 
CHAPTER FOUR 
SYSTEM CONFIGURATION  

Page 95

INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY1991 
PARAGRAPH TABLEOFCONTENTS 
SUBJECT . 
PAGE 
1 
1.10 
2 
I 2.10 
2.20 
2.30 
2.40 
2.50 
1 2.60 
2.70 
2.80 
I 2.90 
3 
4 
4.00 
4.10 
4.20 
I 4.30 
4.40 
TABLE 
4-A 
4-B 
4-c 
4-D 
4-E 
4-F 
FIGURE 
4-1 
4-2 INTRODUCTION ..................................................................................................... 
System Considerations.. ...................................................................................... 
OPTION...

Page 96

INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY 1991 
I 
1 INTRODUCTION 
1.01 STRATA DK systems are flexible in their 
ability to meet varied system needs. A modular 
building block approach allows the addition of vari- 
ous parts to meet system needs and applications. 
A universal slot concept is used in the KSU, which 
means that a PCB slot in the KSU can accept any 
one of a number of different PCBs. This is con- 
trasted with a dedicated slot approach (used in 
previous STRATA systems),...

Page 97

INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY1991 
DK24 (PCTUS) 
I CO Lines 
16 16 16 16 
12 24 12 24 
8 24 8 32 
4 24 4 323 
0 24 0 323 
Stations 
Table 4-A 
OK24/56/96 MAXIMUM CONFIGURATIONS 
DK 24 (PCTU 1,2. or 31 DK56 (PCTU 1.2. or : I I 
CO Lines Stations 
. 
CO Lines 
, , 
Stations 
20 24 
16 32 
12 40 
8 48 
4 
56 
0 64 
DK96 (PC- 
CO Line5 
36 
32 
28 
24 
20 
16 
12 
8 
1, 2, or: 
Stations 
NOTES: 
1. The station capacities apply to any combination of standard telephones, IOOO-series...

Page 98

0 
Two PCOU PCBs 
Two PEKU PCBs 
One PSTU PCB 
Each of these PCBs requires one universal 
slot, so a total of five slots is required. There- 
fore, a DK24 can be used. 
Example 2-A bank branch office needs nine CO 
I lines, seven electronic telephones, five digital 
telephones, and 11 standard rotary type tele- 
phones. 
l The PCB configuration (in addition to Release 
3 common equipment) is as follows: 
Three PCOU PCBs 
One PEKU PCB 
I One PDKU PCB 
Two PSTU PCBs 
l The configuration requires seven...

Page 99

INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY1991 
telephones). Each DDSS console does not require 
a specialized interface PCB; instead, each DDSS 
console takes the place of one digital telephone on 
a PDKU PCB. However, only one DDSS console 
may be interfaced to a PDKU, and it must interface 
to circuit 8. Likewise, each DSS console does not 
require a specialized interface PCB; instead, each 
DSS console takes the place of two electronic 
telephones on a PEKU PCB. However, only one 
DSS...

Page 100

INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY1991 
be needed. The three CO linescan be handled 
by one PCOU PCB. 
The two modems are configured in a system 
modem pool and if no dedicated CO lines are 
provided, then one standard telephone 
(PSTWPESU) station port is required for 
each; therefore a PESU or PSTU would be 
needed. The PCBs required for this configu- 
ration are as follows: 
Two PDKUs 
One PCOU 
One PESU or PSTU 
A total of four universal stations needed. 
A DK24 would suffice...
Start reading Toshiba Strata Dk24, Dk56, Dk96 Instruction Manual

Related Manuals for Toshiba Strata Dk24, Dk56, Dk96 Instruction Manual

All Toshiba manuals