Home > Toshiba > Communications System > Toshiba Strata Dk24, Dk56, Dk96 Instruction Manual

Toshiba Strata Dk24, Dk56, Dk96 Instruction Manual

Here you can view all the pages of manual Toshiba Strata Dk24, Dk56, Dk96 Instruction Manual. The Toshiba manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 81

INSTALLATION-SYSTEM DESCRIPTION 
SECTION 200-096-202 
FEBRUARY1991 
TABLE2-F 
DK96MODELCONTROLSANDlNDlCATORS 
CONTROL/INDICATOR 
Figure 2-13 Item No.) TYPE OF COMPONENT DESCRIPTION 
3N/OFF Switch (1) Two-position rocker switch Power switch for application of AC 
input power from wall socket to KSU 
power supply 
AC IN Connector (2) 3-pin keyed male connector Interface connector for application of 
AC power from wall outlet 
Interface connector for LG/FG ground 
LG/FG Connector (3) 2-pin keyed male...

Page 82

INSTALLATION-SYSTEM DESCRIPTION 
SECTION 200-096-202 
FEBRUARY1991 
TABLE2-F 
DK96MODELCONTROLSANDlNDlCATORS(continued) . 
CONTROL/lNOlCATOR 
(Figure 2-13 Item No.) TYPE OF COMPONENT DESCRIPTION 
Lights to indicate presence of +5VDC 
+5V2 Indicator 
(15) Green LED output from power supply (for KSU’s 
lower PCB shelf backplane) 
-5V Indicator (16) Green LED Lights to indicate presence of -5VDC 
output from power supply 
+5V1 Circuit 
Breaker 
-45V2 Circuit 
Breaker Push-to-reset circuit breaker Circuit...

Page 83

INSTALLATION-SYSTEM DESCRIPTION 
SECTION 200-096-202 
FEBRUARY1991 
HHEU (Loud Ringing Bell/Headset Upgrade): 
Each electronic telephone may also be upgraded 
to provide a loud ringing bell interface and a 
modular headset jack by installing a loud ringing 
bell/headset upgrade assembly (Figure 2-l 6). 
The assembly consists of a small PCB (HHEU) 
which installs on the main PCB, inside the tele- 
phone, with a plug-in connector (HESC-65). 
l An external speaker/amplifier is directly con- 
nected to the...

Page 84

FIGURE 2-17-DOOR PHONE/LOCK CONTROL 
UNIT (HDCB) 
or PEPU) and/orjack B of each HDCBf for up 
to five door lock controls. 
8.34 External Speaker. 
The external speaker 
option is a 3-watt, 6 inch speaker with a built-in 3- 
watt amplifier. A +12VDC power supply (HACU- 
120) is provided with each external speaker, which 
connects to the speaker’s back panel. An 8’ cord is 
provided to plug in the power supply to a 117VAC, 
60 Hz outlet. The HESB has three applications: 
paging speaker, talk-back speaker,...

Page 85

INSTALLATION-SYSTEM DESCRIPTION 
SECTION 200-096-202 
FEBRUARY 1991 
10.01 PCTU3 (Common Control Unit): 
The lat- 
est version of the common control unit is PCTU3, 
which contains 
Release 3 software. The PCTU3 
can be installed in DK96, DK56, and DK24. Like 
earlier PCTU versions, the PCTU3 contains the 
system’s main microprocessor and microproces- 
sor bus, battery-protected memory circuits, time 
switch logic, conference logic, and system tones. 
The PCTU3 also has a music-on-hold/background 
music...

Page 86


				            

Page 87

PARAGRAPH 
1 
2 
3 
3.00 
3.10 
4 
5 
5.10 
I 
6 
7 
7.10 
TABLE 
3-A 
3-B 
3-c 
FIGURE 
3-l 
3-2 
INSTALLATION-SITEREQUIREMENTS 
SECTION 200-096-203 
FEBRUARY1991 
TABLEOFCONTENTS 
. 
SUBJECT 
PAGE 
GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
3-l 
INPUT POWER REQUIREMENTS . . . . . . . 
. . . . . . . . . . . . . . . . ....

Page 88

1 GENERAL 
1.00 
This chapter defines the installation site re- 
quirements necessary to ensure a proper operat- 
ing environment for STRATA DK systems. Also 
included are input power requirements, site con- 
siderations, cable lengths/network requirements, 
and grounding requirements. 
2 INPUT POWER REQUIREMENTS 
2.00 The systems require an input power source 
of 117VAC nominal (85VAC N 135VAC), 50/60 Hz, 
15 amps. The AC outlet must be dedicated to 
system use, fused, and grounded (refer to Para-...

Page 89

INSTALLATION-SITE REQUIREMENTS 
SECTION 200-096-203 
FEBRUARY 1991 
4 CABLE LENGTHS/NETWORK 
REQUIREMENTS 
4.00 Table 3-A lists system loop requirements. 
Table 3-B lists system network requirements. The 
KSU must be located to allow compliance with the 
specified requirements. 
5 GROUNDING REQUIREMENTS 
5.00 The system requires a solid earth ground for 
proper operation. Failure to provide such a ground 
may lead to confusing trouble symptoms and, in 
extreme cases, system failure. The ground con-...

Page 90

INSTALLATION-SITE REQUIREMENTS 
SECTION 200-096-203 
FEBRUARY1991 
TABLE3-A 
LOOPREQUIREMENTS 
Device Description 
PEKU 
(ckts 1 w 8) Electronic 
P&J’ telephone, 
door phone/ 
(ckts 5 N 8) control boxes 
PEKU 
(ckts 7 & 8) DSS consoles 
Max Loop Resistance 
Max Distance from 
(Including Device) KSU to Device 
40 ohms 1000 ft. (303 m) 
20 ohms 
500 ft. (152 m) 
Number of 
Wire Pairs 1 
All need 2-pair. 
EKTs which 
receive OCA 
calls need 
3-pair.’ 
PSTU 
(ckts 1 * 8) 
P&J 2 
(ckts 1 & 2) 
PDKU 
(ckts 1 N...
Start reading Toshiba Strata Dk24, Dk56, Dk96 Instruction Manual

Related Manuals for Toshiba Strata Dk24, Dk56, Dk96 Instruction Manual

All Toshiba manuals