Page 81
INSTALLATION-SYSTEM DESCRIPTION SECTION 200-096-202 FEBRUARY1991 TABLE2-F DK96MODELCONTROLSANDlNDlCATORS CONTROL/INDICATOR Figure 2-13 Item No.) TYPE OF COMPONENT DESCRIPTION 3N/OFF Switch (1) Two-position rocker switch Power switch for application of AC input power from wall socket to KSU power supply AC IN Connector (2) 3-pin keyed male connector Interface connector for application of AC power from wall outlet Interface connector for LG/FG ground LG/FG Connector (3) 2-pin keyed male...
Page 82
INSTALLATION-SYSTEM DESCRIPTION SECTION 200-096-202 FEBRUARY1991 TABLE2-F DK96MODELCONTROLSANDlNDlCATORS(continued) . CONTROL/lNOlCATOR (Figure 2-13 Item No.) TYPE OF COMPONENT DESCRIPTION Lights to indicate presence of +5VDC +5V2 Indicator (15) Green LED output from power supply (for KSU’s lower PCB shelf backplane) -5V Indicator (16) Green LED Lights to indicate presence of -5VDC output from power supply +5V1 Circuit Breaker -45V2 Circuit Breaker Push-to-reset circuit breaker Circuit...
Page 83
INSTALLATION-SYSTEM DESCRIPTION SECTION 200-096-202 FEBRUARY1991 HHEU (Loud Ringing Bell/Headset Upgrade): Each electronic telephone may also be upgraded to provide a loud ringing bell interface and a modular headset jack by installing a loud ringing bell/headset upgrade assembly (Figure 2-l 6). The assembly consists of a small PCB (HHEU) which installs on the main PCB, inside the tele- phone, with a plug-in connector (HESC-65). l An external speaker/amplifier is directly con- nected to the...
Page 84
FIGURE 2-17-DOOR PHONE/LOCK CONTROL UNIT (HDCB) or PEPU) and/orjack B of each HDCBf for up to five door lock controls. 8.34 External Speaker. The external speaker option is a 3-watt, 6 inch speaker with a built-in 3- watt amplifier. A +12VDC power supply (HACU- 120) is provided with each external speaker, which connects to the speaker’s back panel. An 8’ cord is provided to plug in the power supply to a 117VAC, 60 Hz outlet. The HESB has three applications: paging speaker, talk-back speaker,...
Page 85
INSTALLATION-SYSTEM DESCRIPTION SECTION 200-096-202 FEBRUARY 1991 10.01 PCTU3 (Common Control Unit): The lat- est version of the common control unit is PCTU3, which contains Release 3 software. The PCTU3 can be installed in DK96, DK56, and DK24. Like earlier PCTU versions, the PCTU3 contains the system’s main microprocessor and microproces- sor bus, battery-protected memory circuits, time switch logic, conference logic, and system tones. The PCTU3 also has a music-on-hold/background music...
Page 87
PARAGRAPH 1 2 3 3.00 3.10 4 5 5.10 I 6 7 7.10 TABLE 3-A 3-B 3-c FIGURE 3-l 3-2 INSTALLATION-SITEREQUIREMENTS SECTION 200-096-203 FEBRUARY1991 TABLEOFCONTENTS . SUBJECT PAGE GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-l INPUT POWER REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . ....
Page 88
1 GENERAL 1.00 This chapter defines the installation site re- quirements necessary to ensure a proper operat- ing environment for STRATA DK systems. Also included are input power requirements, site con- siderations, cable lengths/network requirements, and grounding requirements. 2 INPUT POWER REQUIREMENTS 2.00 The systems require an input power source of 117VAC nominal (85VAC N 135VAC), 50/60 Hz, 15 amps. The AC outlet must be dedicated to system use, fused, and grounded (refer to Para-...
Page 89
INSTALLATION-SITE REQUIREMENTS SECTION 200-096-203 FEBRUARY 1991 4 CABLE LENGTHS/NETWORK REQUIREMENTS 4.00 Table 3-A lists system loop requirements. Table 3-B lists system network requirements. The KSU must be located to allow compliance with the specified requirements. 5 GROUNDING REQUIREMENTS 5.00 The system requires a solid earth ground for proper operation. Failure to provide such a ground may lead to confusing trouble symptoms and, in extreme cases, system failure. The ground con-...
Page 90
INSTALLATION-SITE REQUIREMENTS SECTION 200-096-203 FEBRUARY1991 TABLE3-A LOOPREQUIREMENTS Device Description PEKU (ckts 1 w 8) Electronic P&J’ telephone, door phone/ (ckts 5 N 8) control boxes PEKU (ckts 7 & 8) DSS consoles Max Loop Resistance Max Distance from (Including Device) KSU to Device 40 ohms 1000 ft. (303 m) 20 ohms 500 ft. (152 m) Number of Wire Pairs 1 All need 2-pair. EKTs which receive OCA calls need 3-pair.’ PSTU (ckts 1 * 8) P&J 2 (ckts 1 & 2) PDKU (ckts 1 N...