Page 101
INSTALLATION-CONFIGURATION SECTION 200-096-204 FEBRUARY1991 tronic telephones with OCA must also be upgraded with an EOCU subassembly. However, PDKU PCBs supporting digital telephones with OCA require no such upgrade. Telephones calling to an OCA- equipped digital or electronic telephone do not require an upgrade. l To receive OCA calls, a digital telephone must be upgraded with asubassembly called DVSU. Each digital telephone can be so equipped. l To receive OCA calls, an electronic...
Page 102
Four PCOU PCBs One PEMU PCB Six PEKU PCBs One PSTU PCB One PIOU PCB One EOCU subassembly One CRCU subassembly l A total of 13 universal slots (one for each of the PCBs with the prefix “P”) will be used in this DK96 system. It is working with 18 tele- phone lines and 48 station devices so it is quite a large system. Another five electronic telephones could be added without requiring use of another universal slot. 2.70 Miscellaneous 2.71 Other hardware items may be needed in a particular...
Page 103
INSTALLATION-CONFIGURATION SECTION 200-096-204 FEBRUARY 1991 CONFIGURATION GUIDE, WORKSHEET 1 Customer: Location: Complete Worksheet 1 before proceeding with other worksheets. Al. DSS consoles required (refer to HDSS in Table 4-E): 1 (Al) HDSS I A2. Door phones/locks required (refer to HDCB in Table 4-E): 1 (A2) HDCBs 1 A3. Electronic telephones required (refer to PEKU and PESU in Table 4-C): NOTE: If upgrading an existing STRATA DKsystem using ZOOO-/3000-/6000-/6005-series electronic...
Page 104
INSTALLATION-CONFIGURATION SECTION 200-096-204 FEBRUARY 1991 WORKSHEET 1 (continued) B2. Number of auxiliary devices/ports, i.e., voice mail ports, auto attendant ports, fax machines, modems (refer to PSTU and PESU in Table 4-C). I( ) B2 Auxiliary devices: I C. Number of CO lines required (refer to PCOU in Table 4-C): D. Number of E&M TIE lines required (refer to PEMU in Table 4-C): E. Does the customer require options that interface with a PIOU, PIOUS, or PEPU PCB? Yes No--- (refer to Table...
Page 105
INSTALLATION-CONFIGURATION SECTION 200-096-204 FEBRUARY 1991 CONFIGURATION GUIDE, WORKSHEET 2 (PEKLVPDKU PCB requirements) Customer Location B. PEKU PCBs (eight station ports) 1. Determine the total PEKU ports required using Chart 1. CHART I-PEKU PORT REQUIREMENTS Equipment Type: Equipment Quantity x (Ports/ per) = Ports Used DSS consoles: (Al) x 2 = (see Worksheet 1, Al) HDCB controllers: VW x 1 = (see Worksheet 1, A2) Electronic telephones: (A3) x 1 = (see Worksheet 1, A3) BGM/MOH...
Page 106
INSTALLATION-CONFIGURATION SECTION 200-096-204 FEBRUARY 1991 CONFIGURATION GUIDE, WORKSHEET 2 (continued) (PEKWPDKU PCB requirements) Customer Location AA. PDKU PCBs (eight station ports) 1. Determine the total PDKU ports required using Chart IA. CHART IA-PDKU PORT REQUIREMENTS Equipment Type: Equipment Quantity x (Ports/ per) = Ports Used DDSS consoles: (AAI) x 1 = (see Worksheet 1, AAI) PDIU-DSs: (AA2) x 1 = (see Worksheet 1, AA2) Digital telephones (with VW x 1 = or without...
Page 107
INSTALLATION-CONFIGURATION SECTION 200-096-204 FEBRUARY 1991 CONFlGURJiTlON GUIDE, WORKSHEET 3 (PSTWPESU PCB requirements) B. PSTU PCBs (eight station ports) 1. Determine the total PSTU ports required using Chart 3. CHART 3-PSTU PORT REQUIREMENTS Equipment Type: Equipment Quantity X Ports = Ports Used Standard telephones: WI x 1 = (see Worksheet 1, Bl) Other devices: WI x 1 = (see Worksheet 1, B2) Total PSTU Ports = 2. Determine the actual PSTU PCB requirements using Chart 4. CHART...
Page 108
INSTALLATION-CONFIGURATION SECTION 200-096-204 FEBRUARY 1991 CONFIGURATION GUIDE, WORKSHEET 4 C. PCOU PCBs (four CO lines) 1. Enter the number of CO lines required from Paragraph C of Worksheet 1. CO lines 2. Determine the number of PCOU PCBs using Chart 5. CHART 5-ACTUAL PCOU PCB REQUIREMENTS co Lines 01-04 05-08 09-12 13-16 17-20 21-24 25-28 29-32 33-36 (C) above PCOU PCBs 1 2 3 4 5 6 7 8 9 Actual PCOU PCBs = -.Ac-u ( D. PEMU PCBs (four TIE lines) 1. Enter the number of TIE lines from...
Page 109
INSTALLATION-CONFIGURATION SECTION 200-096-204 FEBRUARY 1991 I I I I I I I I I I CONFIGURATION GUIDE, WORKSHEET 5 F. System and Slot Check . 1. Add total PCB/slot requirements (from Worksheets 2 N 4): AT + AAT+ BTl + BT2 + CT + DT + ET = total. PCB/slot IMPORTANT NOTE! One or two additional slots should always be considered for future growth. 2. If total is six or less, use DK24 and PCTUSl with the following considerations: a. Total PEKU/PSTU/PESU PCBs combined: three or less (no...
Page 110
INSTALLATION-CONFIGURATION SECTION 200-096-204 FEBRUARY 1991 CONFIGURATION GUIDE, WORKSHEET 6 (miscellaneous option requirements) . G. CRCU PCBs (refer to Table 4-F): 1. A CRCU (-4 or -8) must be installed on the PCTUSl or PCTU2 or PCTU3 PCB if the customer has TIE lines, DISA CO lines, or is using standard telephones or voice mail type devices connected to PSTU or PESU standard telephone ports. 2. For normal traffic, a CRCU-4 (providing four DTMF receiver circuits) will be sufficient. However,...