INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY1991 
tronic telephones with OCA must also be upgraded 
with an EOCU subassembly. However, PDKU PCBs 
supporting digital telephones with OCA require no 
such upgrade. Telephones calling to an OCA- 
equipped digital or electronic telephone do not 
require an upgrade. 
l To receive OCA calls, a digital telephone must be 
upgraded with asubassembly called DVSU. Each 
digital telephone can be so equipped. 
l To receive OCA calls, an electronic...

Page 102

Four PCOU PCBs 
One PEMU PCB 
Six PEKU PCBs 
One PSTU PCB 
One PIOU PCB 
One EOCU subassembly 
One CRCU subassembly 
l A total of 13 universal slots (one for each of 
the PCBs with the prefix “P”) will be used in 
this DK96 system. It is working with 18 tele- 
phone lines and 48 station devices so it is 
quite a large system. Another five electronic 
telephones could be added without requiring 
use of another universal slot. 
2.70 Miscellaneous 
2.71 
Other hardware items may be needed in a 
particular...

Page 103

INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY 1991 
CONFIGURATION GUIDE, WORKSHEET 1 
Customer: Location: 
Complete Worksheet 1 before proceeding with other worksheets. 
Al. DSS consoles required (refer to HDSS in Table 4-E): 1 (Al) HDSS 
I 
A2. Door phones/locks required (refer to HDCB in Table 4-E): 
1 (A2) HDCBs 1 
A3. Electronic telephones required (refer to PEKU and PESU in Table 4-C): 
NOTE: 
If upgrading an existing STRATA DKsystem using ZOOO-/3000-/6000-/6005-series electronic...

Page 104

INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY 1991 
WORKSHEET 1 (continued) 
B2. Number of auxiliary devices/ports, i.e., voice mail ports, auto attendant ports, fax machines, 
modems (refer to PSTU and PESU in Table 4-C). 
I( ) B2 Auxiliary devices: 
I 
C. Number of CO lines required (refer to PCOU in Table 4-C): 
D. Number of E&M TIE lines required (refer to PEMU in Table 4-C): 
E. Does the customer require options that interface with a PIOU, PIOUS, or PEPU PCB? Yes 
No--- (refer to Table...

Page 105

INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY 1991 
CONFIGURATION GUIDE, WORKSHEET 2 
(PEKLVPDKU PCB requirements) 
Customer Location 
B. PEKU PCBs (eight station ports) 
1. Determine the total PEKU ports required using Chart 1. 
CHART I-PEKU PORT REQUIREMENTS 
Equipment Type: Equipment 
Quantity x (Ports/ 
per) = Ports Used 
DSS consoles: 
(Al) x 2 = 
(see Worksheet 1, Al) 
HDCB controllers: 
VW x 1 = 
(see Worksheet 1, A2) 
Electronic telephones: 
(A3) x 1 = 
(see Worksheet 1, A3) 
BGM/MOH...

Page 106

INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY 1991 
CONFIGURATION GUIDE, WORKSHEET 2 
(continued) 
(PEKWPDKU PCB requirements) 
Customer Location 
AA. PDKU PCBs (eight station ports) 
1. Determine the total PDKU ports required using Chart IA. 
CHART IA-PDKU PORT REQUIREMENTS 
Equipment Type: Equipment 
Quantity x (Ports/ 
per) = Ports Used 
DDSS consoles: (AAI) x 1 = 
(see Worksheet 1, AAI) 
PDIU-DSs: (AA2) x 1 = 
(see Worksheet 1, AA2) 
Digital telephones (with 
VW x 1 = 
or without...

Page 107

INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY 1991 
CONFlGURJiTlON GUIDE, WORKSHEET 3 
(PSTWPESU PCB requirements) 
B. PSTU PCBs (eight station ports) 
1. Determine the total PSTU ports required using Chart 3. 
CHART 3-PSTU PORT REQUIREMENTS 
Equipment Type: Equipment 
Quantity X Ports = Ports Used 
Standard telephones: 
WI x 1 = 
(see Worksheet 1, Bl) 
Other devices: 
WI x 1 = 
(see Worksheet 1, B2) 
Total PSTU Ports = 
2. Determine the actual PSTU PCB requirements using Chart 4. 
CHART...

Page 108

INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY 1991 
CONFIGURATION GUIDE, WORKSHEET 4 
C. PCOU PCBs (four CO lines) 
1. Enter the number of CO lines required from Paragraph C of Worksheet 1. 
CO lines 
2. Determine the number of PCOU PCBs using Chart 5. 
CHART 5-ACTUAL PCOU PCB REQUIREMENTS 
co 
Lines 01-04 05-08 09-12 13-16 17-20 21-24 25-28 29-32 33-36 
(C) above 
PCOU 
PCBs 1 2 3 4 5 6 7 8 9 
Actual PCOU PCBs = 
-.Ac-u ( 
D. PEMU PCBs (four TIE lines) 
1. Enter the number of TIE lines from...

Page 109

INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY 1991 
I 
I 
I 
I 
I 
I 
I 
I 
I 
I 
CONFIGURATION GUIDE, WORKSHEET 5 
F. System and Slot Check . 
1. Add total PCB/slot requirements (from Worksheets 2 N 4): AT + AAT+ BTl + BT2 + CT + DT + ET 
= 
total.  PCB/slot 
IMPORTANT NOTE! 
One or two additional slots should always be considered for future growth. 
2. If total is six or less, use DK24 and PCTUSl with the following considerations: 
a. Total PEKU/PSTU/PESU PCBs combined: three or less (no...

Page 110

INSTALLATION-CONFIGURATION 
SECTION 200-096-204 
FEBRUARY 1991 
CONFIGURATION GUIDE, WORKSHEET 6 
(miscellaneous option requirements) 
. 
G. CRCU PCBs (refer to Table 4-F): 
1. A CRCU (-4 or -8) must be installed on the PCTUSl or PCTU2 or PCTU3 PCB if the customer 
has TIE lines, DISA CO lines, or is using standard telephones or voice mail type devices 
connected to PSTU or PESU standard telephone ports. 
2. For normal traffic, a CRCU-4 (providing four DTMF receiver circuits) will be sufficient. However,...