Page 691

Strata AirLink Systems
RWIU System Installation
Strata DK I&M 5/9916-39
Strata AirLink Systems
 
Important!For Strata DK40i, if there are 8 handsets, the RWIU can be installed in any of the 
expansion cabinet slots (15, 16, and 18). If there are 16 handsets, the RWIU must be 
installed in slot 15 and Slot 16 must be vacant. This system cannot support 24 or 32 
handsets because of a port limitation.
Step 4: Install the RWIU/WWIS into the Strata DK
1. Insert the RWIU (WWIS and components facing right) into...

Page 692

Strata AirLink Systems
RWIU System Installation
16-40Strata DK I&M 5/99
3. Connect one end of each cable into the RJ-45 
jacks on the RWIU/WWIS (Point B in Figure 
16-26) and the other end (reversed) into the EMI 
box (Point A in Figure 16-26). The RJ-45 transmit 
and receive pins are shown in Figure 16-25.
4. Connect each end of the other set of cables into 
the RJ-45 jacks of the EMI box (Point C - To Base 
Stations in Figure 16-26) and run the opposite end 
out to the Base Stations.
 
Figure 16-26 EMI...

Page 693

Strata AirLink Systems
RWIU System Installation
Strata DK I&M 5/9916-41
Strata AirLink Systems
Step 7: Connect the Power Supply
The maximum available PBX power for each RWIU PCB is one amp (+5VDC).
1. Use the external power supply (see Figure 16-27) to 
increase the amps for each Base Station.
The power supply has a -40VDC power connector 
for direct connection to the RWIU.
2. Connect to 110VAC power, but do not power on.
Step 8: Use the Proper Power Factor (PF)
äCheck the +5VDC PF using Table 16-15 as a...

Page 694

Strata AirLink Systems
RWIU System Installation
16-42Strata DK I&M 5/99
RBSU2 0.0 1.0 Does not use +5VDC.
RBUS 0.0 0.3 Does not use +5VDC.
RBUU 0.0 1.0 Does not use +5VDC.
RCIS 0.3 0.1
RCIU, RCIU2 0.7 0.2
RCMS 0.6 0.3
RCOS, RCOS2 1.7 2.0
RCOU (4 CO) 2.5 2.0
RCOU + RCOS (8 CO) 3.6 4.0
RCOU, RCOU2 1.9 2.0
RCTUA 2.0 1.0
RCTUB 4.0 1.0
RCTUBA/BB 4.0 1.9
RCTUC/D 4.5 1.9
RCTUE/F 10.0 1.9
RDDU 2.6 7.0
RDSU/RDSS (-24VDC) 1.1 0.3 With 4 DKTs and 4 SLTs.
RDSU + R48S (-48VDC) 1.1 0.5
RDTU 1.8 1.0
REMU2/PEMU 1.0 7.5...

Page 695

Strata AirLink Systems
RWIU System Installation
Strata DK I&M 5/9916-43
Strata AirLink Systems
 
Step 9: Program the Strata DK
Important!Do not use a DKT that has an intercom button for Speed Dial programming.
1. Determine how many handsets, PDKU ports, and available slots are required before 
programming the Strata DK. Up to 32 handsets per RWIU are allowed.
2. Use the following programs:
©Program 03 for Code 61 (slot assignments).
©Program 32 for Auto Preference.
©Program 39 for flexible button...

Page 696

Strata AirLink Systems
RWIU System Installation
16-44Strata DK I&M 5/99
Step 10: Connect the PC
äRun the RS-232-C cable to the back 
of the PC (COM port 1) and insert 
the 6-pin connector into the RWIU 
jack (see Figure 16-28).
Busy Override/Busy Station Transfer/Busy 
Station RingingHeadset Interface
Call Forward: Headset Receiver Volume Control
lAll Calls Hearing Aid Compatible
lBusy Liquid Crystal Display (LCD)
lNo Answer Message Waiting Indication
lBusy/No Answer Multiple Message Waiting
lFixed...

Page 697

Strata AirLink Systems
RWIU System Installation
Strata DK I&M 5/9916-45
Strata AirLink Systems
Step 11: Initialize the RWIU
1. Open the RWIU Manager software.
2. Turn on the Strata DK. The RWIU checks Base Station status and connections.
3. Check the LEDs on the Base Stations. If all the LEDs are OFF, the initialization is complete.
4. Check the handsets for dial tone. If there is dial tone, the initialization is complete.
Step 12: Install the RWIU Manager
1. Check the PC hardware/
software against the...

Page 698

Strata AirLink Systems
RWIU System Installation
16-46Strata DK I&M 5/99
Step 13: Start the RWIU Manager
Step 14: Set General Settings
1. Make sure that the PC is 
connected to the RWIU.
2. From the RWIU program 
group, double-click on the 
Manager icon.
After a few seconds, the Desktop Toolbar displays.
1. From the Desktop Toolbar, 
click the Config icon.
2. Click General Settings and 
assign COM port 1.
3. Click OK.
4. Click System ID.
5. Enter the System ID.
6. Click OK. General Settings window...

Page 699

Strata AirLink Systems
RWIU System Installation
Strata DK I&M 5/9916-47
Strata AirLink Systems
Step 15: Enter the Handset IDs
Step 16: Enable UTAM
7. Click Time and Date.
8. Enter the Date and time.
9. Click OK.
1. From the Desktop Toolbar, 
click the Config icon.
2. Click User Database.
3. Download the settings from 
the RWIU.Default IDs display.
Handset IDs do not have 
to be in numerical order 
and can be changed at any 
time.
4. Click OK. The Desktop Toolbar displays.
5. Upload the settings to the...

Page 700

Strata AirLink Systems
RWIU System Installation
16-48Strata DK I&M 5/99
Step 17: Store the IDs in the Handset
2. Click Get UTAM Code from 
RW IU .
3. Enter the password 
LABUTAM.
4. Click OK twice. The Desktop Toolbar displays.
5. Click Get UTAM code from 
RW IU .The new 20-digit UTAM activation code displays. Call the 
UTAM Activation desk at (949) 598-4980 between the 
hours of 8:00 a.m. and 5:00 p.m. (Pacific Standard Time), 
Monday through Friday with this number.
6. Click OK. The Desktop Toolbar...