Page 191
DK424 Installation Reserve Power Installation Strata DK I&M 5/995-41 DK424 Installation 1. When floor mounting the DK424, the batteries must be installed by a licensed electrician per local electric code using conduit. (See Figures 5-25, 5-21 and 5-22 DKSUE424.) 2. RBTC1A-2M cable current ratings: discharge, 12 amps max./charge, 3.9 amps max. 3. PBTC-3M and RBTC1A-15M cable current ratings: discharge, 4.9 amps max./charge 0.6 amps max. 4. Batteries should be installed in a customer-supplied commercial...
Page 192
DK424 Installation Reserve Power Installation 5-42Strata DK I&M 5/99 Right Side View Loosen bottom two cover screws to remove cover Bottom Cabinet RFMFI +–BATT LNAC120V FG RCCB (Shown with cover off) Loosen top two cover screws to remove cover RCCB1 or RCCB2 (Shown with cover on) Side View of RCCB Conduit Holes to 1/2 Inch (Tradesize) Conduit To RBDB or RBDB2 (Battery Distribution Box) Battery Wires (12-AWG minimum) 24 AMPS MaxAC Power Wire (14-AWG minimum) 11.5 AMPS Max (RCCB1) 17.5 AMPS Max...
Page 193
DK424 Installation Reserve Power Installation Strata DK I&M 5/995-43 DK424 Installation NoteAC/DC wiring and conduit “A” and “B” must be installed by a licensed electrician per local electrical code (conduit trade size is 1/2 inch). See Figure 5-25 on Page 5-41 for battery specifications and wiring guidelines.) Figure 5-27 Reserve Power/AC Wiring for Three to Six Cabinets (Floor Mount) TO RPSU1 + – + – TO RPSU2 TO RPSU3 TO RPSU4 TO RPSU5 TO RPSU6 BATT PSU + –BATT AC120VL N FG A BA B 1 6•...
Page 194
DK424 Installation Reserve Power Installation 5-44Strata DK I&M 5/99 CAB 1 RPSB1A RPSB1A EXP EXP EXP EXP EXP EXP BASE RPSU280A RPSU280ASeventh Cabinet BATT Cable supplied with RCTC1A-1.7M BATT AC IN BATT AC IN RPSU280A BATT AC IN RPSU280A BATT AC IN RPSU280A BATT AC IN RPSU280A Cabinet 1 (Base) Cabinet 2 (Expansion) Cabinet 3 (Expansion) Cabinet 4 (Expansion) Cabinet 5 (Expansion) Cabinet 6 (Expansion) Cabinet 7 (Expansion)MBJU Jumper Unit BATT AC IN RPSU280A External Battery (27.3VDC/35A max.) AC...
Page 195
DK424 Installation Printed Circuit Board (PCB) Installation Strata DK I&M 5/995-45 DK424 Installation Printed Circuit Board (PCB) Installation This section provides procedures for the installation of DK424 Base and Expansion Printed Circuit Boards (PCBs). It includes installation instructions, optional configuration information, wiring, and programming considerations for each PCB. The DK424 system Base and Expansion Cabinets are shipped empty. The power supplies and PCBs are not installed at the...
Page 196
DK424 Installation RCTUA, RCTUBA/BB, RCTUC/D, RCTUE/F Common Control Units 5-46Strata DK I&M 5/99 Hardware Options Some PCBs must be configured for hardware options prior to installation of the PCB in the cabinet. Configuration instructions for internal hardware options are provided in the individual PCB installation procedures in this chapter. Configuration instructions for external hardware options are provided in Chapter 10 – Peripheral Installation. Software Options PCBs are configured for...
Page 197
DK424 Installation RCTUA, RCTUBA/BB, RCTUC/D, RCTUE/F Common Control Units Strata DK I&M 5/995-47 DK424 Installation Figure 5-29 RCTU Slot Placement Maximum Line Capacities Configurations for a fully-expanded system can range from 40 lines/ 336 stations to a squared system of 200 outside lines/192 stations. Table 5-5 Maximum Line Capacities by Processor Type Common Control UnitNumber of CabinetsMaximum Lines Stations RCTUA one Cabinet (Base Cabinet) 16 32 RCTUBA/BBup to two Cabinets (Base Cabinet plus...
Page 198
DK424 Installation RCTUA, RCTUBA/BB, RCTUC/D, RCTUE/F Common Control Units 5-48Strata DK I&M 5/99 Additionally, each of the common control units can support a separate set of features. Refer to Chapter 4 – Configuration for more information. Each of the common control units (except RCTUBB) may be equipped with an RRCS (4, 8, or 12) to interpret Dual-Tone Multi-Frequency (DTMF) signals transmitted from Tie/DID lines, built-in AA and standard telephone ports. The common control units also provide an...
Page 199
DK424 Installation RCTUA, RCTUBA/BB, RCTUC/D, RCTUE/F Common Control Units Strata DK I&M 5/995-49 DK424 Installation Music-on-hold/Background Music Volume Control (External Options) Each of the common control units (except RCTUBB, RCTUD and RCTUF) has a trim potentiometer (VR1) to adjust the volume of the MOH/BGM source connected to the Music-on- hold (MOH)/Background Music (BGM) RCA jack interface, which is also on the common control unit. The volume control potentiometer and the MOH/BGM interface...
Page 200
DK424 Installation RCTUA, RCTUBA/BB, RCTUC/D, RCTUE/F Common Control Units 5-50Strata DK I&M 5/99 ä To install an RRCS onto RCTUA, RCTUBA/BB, RCTUC/D, or RCTUE/F ä Mate RRCS connectors J1, J2, J3, and J4 (See Figure 5-31) with the applicable RCTU PCB. Apply firm, even pressure to the RRCS to ensure proper mating of the connectors. RCTUA connectors are P2, P3, P4, P5. (See Figure 5-32.) RCTUBA connectors are P3, P4, P5, P6. (See Figure 5-33.) RCTUC connectors are P3, P4, P5, and P6; RCTUD connectors...