Page 141
DK424 Configuration Worksheet 3 – System PCB Assignment Guide Strata DK I&M 5/994-29 DK424 Configuration Worksheet 3 – System PCB Assignment Guide Fill in Worksheet 3 by recording PCBs in the following order (see Worksheet 1 for PCB type and quantities): 1. Write in the Cabinet Type. 2. Enter the RCTU PCBs as required: ©RCTUBA, RCTUC, or RCTUE in slot R11 ©RCTUA, RCTUBB, RCTUD, or RCTUF in slot RCTU 3. Enter PDKU, PEKU, or RSIU in slot 11. ...and/or if an RSIU is installed in slot 11, install a PDKU...
Page 142
DK424 Configuration Worksheet 3 – System PCB Assignment Guide 4-30Strata DK I&M 5/99 1. Type = DK280, DK424, or NR (not required). Double-check after completing all worksheets, particularly Worksheet 5 - System Power Factor Check. 2. Cabinets 2~7: Last two slots are available on the DK424 using RCTUE/F processors, with MBJU removed.Cabinet 1 (Type: 1 ) R11 RCTU S11 S12 S13 S14 S15 S16 PCB Type Port Nos. Line Nos. Option/Note Cabinet 2 (Type: 1 ) S21 S22 S23 S24 S25 S26 S272S282...
Page 143
DK424 Configuration Worksheet 4 – Option Configuration Guide Strata DK I&M 5/994-31 DK424 Configuration Worksheet 4 – Option Configuration Guide OptionNumber RequiredComments RRCS PCB RRCS-4 RRCS-8 RRCS-12An RRCS (-4, -8 or 12 DTMF receiver circuits) must be installed on the RCTUA, RCTUB, RCTUBA/BB, RCTUC/D, or RCTUE/F if the customer has: DTMF DID, Tie, ANI, DNIS, DISA lines (remote change of call forward destination), DNIS External Call Routing, using DTMF standard telephones, or voice...
Page 144
DK424 Configuration Worksheet 4 – Option Configuration Guide 4-32Strata DK I&M 5/99 DPFT Unit The DPFT provides a means to connect eight selected CO lines to standard telephones in the event of a power failure (each DPFT requires an RSTU or PSTU PCB). There is no limit to the number of DPFTs installed, provided that the system power factor is not exceeded. MDFB The MDFB door phone option plugs into the DDCB or HDCB control box to provide a door phone. Three MDFBs can be connected to each DDCB or...
Page 145
DK424 Configuration Worksheet 4 – Option Configuration Guide Strata DK I&M 5/994-33 DK424 Configuration Stratagy or VP Voice MailRefer to Toshiba Stratagy or VP documentation for detailed information about the VM machines and to C2 of Worksheet 2 in this chapter for DK424 VM port requirements. PC Attendant Consoles (with RATI and RATHC) DKAdmin/ Backup SMIS for ACDThese features require customer-supplied personal computers. See feature user guides for individual personal computer...
Page 146
DK424 Configuration Worksheet 5 – System Power Factor Check 4-34Strata DK I&M 5/99 Worksheet 5 – System Power Factor Check The Strata DK power supply was engineered for maximum cost efficiency to provide power for the most configurations. Because of this design, some power limitations exist when using old electronic-type telephones and/or telephone option hardware. For example, only 24 3000-series telephones can be installed in a cabinet. Each telephone and PCB has a negative Power Factor (PF) and...
Page 147
DK424 Configuration Worksheet 5 – System Power Factor Check Strata DK I&M 5/994-35 DK424 Configuration NotePower factor calculation samples are shown in Tables 4-24 and 4-25. Table 4-24 Strata DK424 Base Cabinet Table 4-25 Strata DK424 Expansion Cabinet RCTUB 4.0 1.0 RCTUBA/BB 4.0 1.9 RCTUC/D 4.5 1.9 RCTUE/F 10.0 1.9 RDDU 2.6 7.0 RDSU (-24VDC) 1.1 0.3 With 4 DKTs and 4 SLTs. RDSU + R48S (-48VDC) 1.1 0.5 RDTU 1.8 1.0 REMU2/PEMU 1.0 7.5 RGLU1A/2A 2.1 2.5 RMCU1A 0.7 0.3 RMDS1A 0.35 0.16 2400 bps...
Page 148
DK424 Configuration Worksheet 5 – System Power Factor Check 4-36Strata DK I&M 5/99 Telephone/Device Power Factors The power supply of each cabinet supplies a limited amount of power. For each cabinet, calculate the total Telephone/Device PF and add it to the appropriate cabinet in “Cabinet Power Factor, PCB/Telephone Device” on Page 4-38. Telephone/Device Base Cabinet (1)Expansion Cabinet (2)Expansion Cabinet (3)Expansion Cabinet (4) Qty. PF Total Qty. PF Total Qty. PF Total Qty. PF Total Digital...
Page 149
DK424 Configuration Worksheet 5 – System Power Factor Check Strata DK I&M 5/994-37 DK424 Configuration Telephone/Device Expansion Cabinet (5)Expansion Cabinet (6)Expansion Cabinet (7) Qty. PF Total Qty. PF Total Qty. PF Total Digital Telephone (DKT, any series) 1~120 Telephones x 1.0 = x 1.0 = x 1.0 = 121~240 Telephones x 0.6 = x 0.6 = x 0.6 = 2000-series Electronic Telephone (EKT)x 2.0 = x 2.0 = x 2.0 = 3000-series EKT x 2.5 = x 2.5 = x 2.5 = 6000-series EKT x 2.0 = x 2.0 = x 2.0 = 6005-series...
Page 150
DK424 Configuration Worksheet 5 – System Power Factor Check 4-38Strata DK I&M 5/99 Cabinet Power Factor, PCB/Telephone Device Calculate the total PF of each cabinet (must be less than 65). See Worksheet 2, Table 4-9 for PCB quantity and type, and Table 4-23 for PF numbers. The Total Cabinet PF must not exceed the limits shown in Max. PF Allowed, at the bottom of this chart. NoteCabinets 2~7: Last two slots are available on the DK424 (RCTUE/F). Cabinets 1234567 PCB TypePF PCB TypePF PCB TypePF PCB...