Page 101
DK40i Installation Printed Circuit Board (PCB) Installation Strata DK I&M 5/993-33 DK40i Installation TDDU Four-circuit DID Line Digital Telephone Interface Unit System:DK40i Base KSU (mounts on KSU TMAU) Circuits per PCB:four DID line circuits Interfaces with:DID lines Older Version(s):none The optional TDDU PCB installs onto the TMAU motherboard. (See Figure 3-22 and Ta b l e 3 - 8 for information on controls, indicators and connectors and Figure 3-27 for wiring.) NoteOnly one TCOU or TDDU can be...
Page 102
DK40i Installation Printed Circuit Board (PCB) Installation 3-34Strata DK I&M 5/99 ©Assigns Immediate or Wink start to DID lines and auto camp-on and no-dial tone return for DID lines. ©Assigns DID lines to route per DNIS and ANI options (Program 71 and 72) or DID numbers (Program *09). Program 30: Disables RRCS for dial pulse operation. Program 40: Assigns station access to lines (incoming and outgoing). Program 41: Assigns station access to lines (outgoing only). Program 42-0, 1~8: Assigns behind...
Page 103
DK40i Installation Printed Circuit Board (PCB) Installation Strata DK I&M 5/993-35 DK40i Installation CAUTION!Port numbers in the Expansion KSU shift by four ports if KSTU2 or TDDU is installed (or removed after it is installed). This determines whether or not the DDCB can be connected on the KCDU in slot 15. Table 3-8 TDDU Controls, Indicators, and Connectors Control/Indicator/ConnectorType of ComponentDescription CO line busy LEDs 1~4 (DID1~DID4)Red LEDLights to indicate DID line circuit is...
Page 104
DK40i Installation Printed Circuit Board (PCB) Installation 3-36Strata DK I&M 5/99 TSIU Serial Interface Board System:DK40i Base KSU (plugs into KSU main PCB) Circuits per PCB:two TTY/RS-232 interface ports Interfaces with:SMDR connection for call accounting device customer-provided external modem for local/remote maintenance from a PC with DK Admin Older Version(s):none The TSIU PCB enables the DK40i system to connect to various hardware devices. It does not have an internal modem and does not...
Page 105
DK40i Installation Printed Circuit Board (PCB) Installation Strata DK I&M 5/993-37 DK40i Installation Program 76-2X-Z: Assigns each installed TSIU port to operate at a specified transmission rate. Where X identifies the TSIU Port number (1, 2). Z identifies the TSIU/port transmission rate in bits-per-second (bps): ©Z=1; 9600 ©Z=2; 4800 ©Z=3; 2400 ©Z=4; 1200 NoteThe sum of TSIU port 1 and port 2 bps rate cannot exceed 9600 bps. TSIU1A 1634 SIO#1 SIO#2SIO#1 SIO#2 Figure 3-23 Serial Interface Board (TSIU)...
Page 106
DK40i Installation Universal Slot PCBs 3-38Strata DK I&M 5/99 Universal Slot PCBs The following PCBs can be used in the universal slots of either the Strata DK40i Expansion KSU or the Strata DK424 cabinets (see Table 3-9). Table 3-9 Universal Slot PCB Descriptions PCBTitleDescriptionPage KCDUCO Line/Digital Interface UnitProvides two loop start CO line circuits and four digital telephone circuits.7-4 PDKUDigital Telephone Interface Unit Provides eight digital telephone circuits that can support...
Page 107
DK40i Installation Loop Limits Strata DK I&M 5/993-39 DK40i Installation Loop Limits This section provides the maximum loop lengths for connection of telephones, lines, peripheral equipment, and power supplies. The following information applies to only the Strata DK40i system (see Table 3-10). Diagrams that are applicable to all systems, including the DK40i, can be found in Chapter 8 – DK40i/DK424 Universal PCB Wiring. Table 3-10 Digital Telephone/DIU/DDSS Console/ADM/Loop Limits ModeDK40i KSU or...
Page 108
DK40i Installation DK40i Secondary Protection 3-40Strata DK I&M 5/99 DK40i Secondary Protection The following diagram (see Figure 3-24) shows where secondary protectors must be installed for outside wiring. Figure 3-24 DK40i Secondary Protector Diagram Important!To protect against transient voltages and currents, solid state secondary protectors must be installed if there is outside wiring, and on all DID and E&M Tie lines. These protectors, which contain fast semiconductors in addition to fuses,...
Page 109
DK40i Installation MDF Wiring Diagrams Strata DK I&M 5/993-41 DK40i Installation MDF Wiring Diagrams Wiring diagrams for the DK40i (listed below) are shown in Figures 3-25~3-27. ©MDF Wiring to KSU & Amphenol Station and Relay Connectors (KSTU2) ©MDF Wiring to CO Lines and Digital Telephones (KCDU) ©MDF Wiring to CO Lines (TCOU and TDDU) See Chapter 8 – DK40i/DK424 Universal Wiring Diagrams for more information. NoteSee Table 3-10 on Page 3-39 for loop limits. Figure 3-25 MDF Wiring to KSU & Amphenol...
Page 110
DK40i Installation MDF Wiring Diagrams 3-42Strata DK I&M 5/99 Figure 3-26 MDF Wiring to CO Lines and Digital Telephones (KCDU) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 47 48 49 501 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 47 48 49 50W-BL BL-W W-O O-W W-GN GN-W W-BR BR-W W-S S-W R-BL BL-R R-O O-R R-GN GN-R R-BR BR-R R-S V-BR BR-V V-S S-V26 1 27 2 28 3 29 4 30 5 31 6 32 7 33 8 34 9 35 49 24 50 25 BRIDGING CLIPS TO KCDU W/FEMALE CONNECTOR 25-PAIR CABLE W/MALE AMP CONNECTOR 66M150 SPLIT BLOCK...