DK40i Installation
Printed Circuit Board (PCB) Installation
Strata DK I&M 5/993-33
DK40i Installation
TDDU
Four-circuit DID Line Digital Telephone Interface Unit
System:DK40i Base KSU (mounts on KSU TMAU)
Circuits per PCB:four DID line circuits
Interfaces with:DID lines
Older Version(s):none
The optional TDDU PCB installs onto the TMAU motherboard. (See Figure 3-22 and Ta b l e  3 - 8 
for information on controls, indicators and connectors and Figure 3-27 for wiring.)
NoteOnly one TCOU or TDDU can be...

Page 102

DK40i Installation
Printed Circuit Board (PCB) Installation
3-34Strata DK I&M    5/99
©Assigns Immediate or Wink start to DID lines and auto camp-on and no-dial tone return 
for DID lines.
©Assigns DID lines to route per DNIS and ANI options (Program 71 and 72) or DID 
numbers (Program *09).
Program 30: Disables RRCS for dial pulse operation.
Program 40: Assigns station access to lines (incoming and outgoing).
Program 41: Assigns station access to lines (outgoing only).
Program 42-0, 1~8: Assigns behind...

Page 103

DK40i Installation
Printed Circuit Board (PCB) Installation
Strata DK I&M 5/993-35
DK40i Installation
CAUTION!Port numbers in the Expansion KSU shift by four ports if KSTU2 or TDDU is 
installed (or removed after it is installed). This determines whether or not the 
DDCB can be connected on the KCDU in slot 15.
Table 3-8 TDDU Controls, Indicators, and Connectors
Control/Indicator/ConnectorType of ComponentDescription
CO line busy LEDs 1~4 
(DID1~DID4)Red LEDLights to indicate DID line circuit is...

Page 104

DK40i Installation
Printed Circuit Board (PCB) Installation
3-36Strata DK I&M    5/99
TSIU
Serial Interface Board
System:DK40i Base KSU (plugs into KSU main PCB)
Circuits per PCB:two TTY/RS-232 interface ports 
Interfaces with:SMDR connection for call accounting device
customer-provided external modem for local/remote maintenance from a PC with
DK Admin
Older Version(s):none
The TSIU PCB enables the DK40i system to connect to various hardware devices. It does not have 
an internal modem and does not...

Page 105

DK40i Installation
Printed Circuit Board (PCB) Installation
Strata DK I&M 5/993-37
DK40i Installation
Program 76-2X-Z: Assigns each installed TSIU port to operate at a specified transmission rate. 
Where X identifies the TSIU Port number (1, 2). Z identifies the TSIU/port transmission rate in 
bits-per-second (bps):
©Z=1; 9600
©Z=2; 4800
©Z=3; 2400
©Z=4; 1200
NoteThe sum of TSIU port 1 and port 2 bps rate cannot exceed 9600 bps.
TSIU1A
1634
SIO#1 SIO#2SIO#1 SIO#2
Figure 3-23 Serial Interface Board (TSIU)...

Page 106

DK40i Installation
Universal Slot PCBs
3-38Strata DK I&M    5/99
Universal Slot PCBs
The following PCBs can be used in the universal slots of either the Strata DK40i Expansion KSU 
or the Strata DK424 cabinets (see Table 3-9).
Table 3-9 Universal Slot PCB Descriptions
PCBTitleDescriptionPage
KCDUCO Line/Digital 
Interface UnitProvides two loop start CO line circuits and four digital 
telephone circuits.7-4
PDKUDigital Telephone 
Interface Unit Provides eight digital telephone circuits that can support...

Page 107

DK40i Installation
Loop Limits
Strata DK I&M 5/993-39
DK40i Installation
Loop Limits
This section provides the maximum loop lengths for connection of telephones, lines, peripheral 
equipment, and power supplies. The following information applies to only the Strata DK40i 
system (see Table 3-10). Diagrams that are applicable to all systems, including the DK40i, can be 
found in Chapter 8 – DK40i/DK424 Universal PCB Wiring.
Table 3-10 Digital Telephone/DIU/DDSS Console/ADM/Loop Limits
ModeDK40i KSU or...

Page 108

DK40i Installation
DK40i Secondary Protection
3-40Strata DK I&M    5/99
DK40i Secondary Protection
The following diagram (see Figure 3-24) shows where secondary protectors must be installed for 
outside wiring.
Figure 3-24 DK40i Secondary Protector Diagram
Important!To protect against transient voltages and currents, solid state secondary protectors 
must be installed if there is outside wiring, and on all DID and E&M Tie lines. 
These protectors, which contain fast semiconductors in addition to fuses,...

Page 109

DK40i Installation
MDF Wiring Diagrams
Strata DK I&M 5/993-41
DK40i Installation
MDF Wiring Diagrams
Wiring diagrams for the DK40i (listed below) are shown in Figures 3-25~3-27.
©MDF Wiring to KSU & Amphenol Station and Relay Connectors (KSTU2)
©MDF Wiring to CO Lines and Digital Telephones (KCDU)
©MDF Wiring to CO Lines (TCOU and TDDU)
See Chapter 8 – DK40i/DK424 Universal Wiring Diagrams for more information.
NoteSee Table 3-10 on Page 3-39 for loop limits.
Figure 3-25 MDF Wiring to KSU & Amphenol...

Page 110

DK40i Installation
MDF Wiring Diagrams
3-42Strata DK I&M    5/99
Figure 3-26 MDF Wiring to CO Lines and Digital Telephones (KCDU)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
47
48
49
501
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
47
48
49
50W-BL
BL-W
W-O
O-W
W-GN
GN-W
W-BR
BR-W
W-S
S-W
R-BL
BL-R
R-O
O-R
R-GN
GN-R
R-BR
BR-R
R-S
V-BR
BR-V
V-S
S-V26
1
27
2
28
3
29
4
30
5
31
6
32
7
33
8
34
9
35
49
24
50
25
BRIDGING
CLIPS TO KCDU
W/FEMALE CONNECTOR
25-PAIR CABLE W/MALE AMP CONNECTOR
66M150 SPLIT BLOCK...
Start reading Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual

Related Manuals for Toshiba Strata Dk14, Dk40i, Dk424 Installation And Maintenance Manual

All Toshiba manuals