Page 71

DK40i Installation
Site Requirements
Strata DK I&M 5/993-3
DK40i Installation
The location must not be:
©Subject to extreme heat or cold
©Subject to corrosive fumes, dust, or other airborne contaminants
©Subject to excessive vibration
©Next to television, radio, office automation, or high frequency equipment
If reserve power is to be installed for the Strata DK40i, the batteries will require a well-ventilated 
location close (within nine feet) to the DKSUB40 (the optional Toshiba-supplied battery cable...

Page 72

DK40i Installation
AC Power and Grounding Requirements
3-4Strata DK I&M    5/99
AC Power and Grounding Requirements
The DK40i requires a solid earth ground for proper operation. 
The AC power cord contains a conductor 
for the “third-wire ground” provided by 
the commercial power outlet. The third-
wire ground should be the only ground 
necessary for the DK40i; this ground 
must originate at the buildings main 
power distribution panel and have a solid 
connection to earth ground. (See Figure 
3-3.)...

Page 73

DK40i Installation
KSU Mounting Considerations
Strata DK I&M 5/993-5
DK40i Installation
6.Set the meter to the “OHMS/Rx1” scale. Place one probe on the ground terminal, and the other 
probe on the terminal that produced a reading of zero volts. The reading should be less than 1 
ohm.
CAUTION!If the reading is more than one ohm, then the outlet is not adequately grounded. 
If the above tests show the outlet AC voltage is not in range or is not properly 
grounded, the condition should be corrected (per...

Page 74

DK40i Installation
KSU Mounting Considerations
3-6Strata DK I&M    5/99
6. The TCOU or TDDU cards have a green and yellow wire with a two-prong spade on the end. 
Slip the spade under the second screw from the right on the power supply (see Figure 3-7).
7. If applicable, install KSTU2 Standard Telephone Interface Unit. The KSTS2  comes pre-
installed onto the KSTU2. Then install both boards into the DK40i Base KSU (see Figures 
3-17~3-19, beginning on Page 3-26).
8. If applicable, install the K5RCU or...

Page 75

DK40i Installation
KSU Mounting Considerations
Strata DK I&M 5/993-7
DK40i Installation
TPSU16 Circuit Breaker Reset Procedure
Case 1
If the AC and DC LEDs on the TPSU16 power supply in the Strata DK40i Base KSU do not light, 
even though the AC power plug is inserted into the wall outlet and the TPSU16 DC power switch 
is turned on, the AC overvoltage circuit breaker may have opened. 
ä
To reset the AC overvoltage circuit breaker
1. Remove the AC power plug from the wall outlet, turn the DC power switch...

Page 76

DK40i Installation
KSU Mounting Considerations
3-8Strata DK I&M    5/99
Mounting the Base KSU
ä
To mount the Base KSU
1. Place the Base KSU on the desired location on the mounting surface and mark the location of 
the four screw holes (there is one on each corner). See Figure 3-6.
Make sure the location of the Base KSU meets the minimum clearance requirements specified 
in Figure 3-1 on Page 3-2.
NoteThe Base KSU AC power cord is 4 feet 5 inches long.
2. Drill holes on these marks. 
If mounting the KSU...

Page 77

DK40i Installation
KSU Mounting Considerations
Strata DK I&M 5/993-9
DK40i Installation
Mounting the Expansion KSU
Important!For purposes of identification, the labels appear on the boxes and Expansion KSUs 
(see Table 3-2).
Table 3-2 Expansion Unit Labels
ä
To mount the Expansion KSU (see Figures 3-4, 3-6, 3-8~3-11)
1. Make sure the side cover is removed from the Base KSU. Turn Base KSU DC power switch 
OFF.
2. Set the Expansion KSU on the Base KSUs hinge mounts, making sure that the Expansion 
KSU sets...

Page 78

DK40i Installation
KSU Mounting Considerations
3-10Strata DK I&M    5/99
 
Method 1Method 2
StudPlaster Board
StudPlaster
Board
Hard Board
(1/2 Inch Plywood)
Expansion
KSU
Base KSUBase KSU
Expansion
KSU
1614
Figure 3-4 KSU Wall Mounting
Base Cover
Side Cover
AC DC
POWER
Cover
Screws (6)
= 
4237
Six cover screws 
to be removed 
before mounting 
KSU
Model: DKSUBI40A
Strata DK40i
Label on edge of
Base KSU
Figure 3-5 Base KSU Exterior 

Page 79

DK40i Installation
KSU Mounting Considerations
Strata DK I&M 5/993-11
DK40i Installation
Figure 3-6 DK40i Base KSU Interior
FG2
POWER SUPPLY ASSEMBLYMODELINPUT: AC127V 2.2A 60 HZOUTPUT: -27.3V 2.8A. -27.3V 0.2A
V. 1A 1996-05 00001TOSHIBA CORPORATION
TPSU16A
MADE INWARNINGHazardous voltage inside!If servicing required
remove A. C. plug.
12
+-BATTPN2 12AC DC
DC  POWER
TMAU2AOFF
ON
4238
Connect Expansion
Unit TB1 TO FG2
Expansion KSU
Cable ReceptacleImportant Notice
Battery Jumper
-24 Volt Circuit...

Page 80

DK40i Installation
KSU Mounting Considerations
3-12Strata DK I&M    5/99
+
-
TCOU1A V1
TC1U2A
Optional with TCOU
(provides Caller ID)
Install a TCOU, TBSU 
or  TDDU here FG Screw
TDDU1A V1
3796
TBSU1AFS
LOS
TS
BSY FS
LOS
TS
BSY
Figure 3-7 CO Line Board Installation into DK40i Base KSU 