Page 61
DK40i Configuration Worksheet 1 – System PCB Assignment Guide Strata DK I&M 5/992-13 DK40i Configuration Example Configuration Tables Table 2-17 Hardware Configuration Example Table 2-18 Strata DK40i Base Cabinet Station Port Configuration Example Table 2-19 Strata DK40i Base Cabinet Line Configuration Example Table 2-20 Strata DK40i Base and Expansion CO Line Configuration Example Base CabinetExpansion Cabinet Slot Number001112131415161718 PCB Type K5RCU2 8 DKTs TBSUKSTU2 4 SLTNone PDKU2RBSU/ RBSSRCOU...
Page 62
DK40i Configuration Configuration Considerations 2-14Strata DK I&M 5/99 Configuration Considerations The following considerations should be taken into account when filling out the tables in “Worksheet 1 – System PCB Assignment Guide”. Base Cabinet 1. Only one line PCB (TCOU, TDDU, or TBSU) can be installed in the Base cabinet. 2. If TBSU is installed, each circuit can be configured independently as a station side or line side S/T BRI circuit. 3. Each TBSU ISDN BRI circuit uses two station ports and...
Page 63
DK40i Configuration Configuration Considerations Strata DK I&M 5/992-15 DK40i Configuration 7. Each Tie or DID line PCB installed provides four Tie or DID lines and does not use four station ports as in the DK40 (PEMU, REMU, RDDU, and RDDU). 8. RWIU can be installed in any of the expansion cabinet slots (15, 16, 17, and 18) to support up to 8 StrataLink handsets. If there are 9 to 16 handsets, the RWIU must be installed in slot 15 and slot 16 must be vacant. This system cannot support 24 or 32...
Page 64
DK40i Configuration Worksheet 2 – System Power Factor Check 2-16Strata DK I&M 5/99 Worksheet 2 – System Power Factor Check The DK power supply was engineered for maximum cost efficiency to provide power for the most configurations. Because of this design, some power limitations exist when using old electronic- type telephones, telephone option hardware, or newer PCBs, such as RWIU, TBSU, RBSU/RBSS. Telephone/Device PFs The power supply of each KSU supplies a limited amount of power. For each KSU,...
Page 65
DK40i Configuration Worksheet 2 – System Power Factor Check Strata DK I&M 5/992-17 DK40i Configuration Worksheet Examples Table 2-23 DK40i Telephone/Device 24 Volt Power Factor Worksheet Example (Base/Expansion KSU) Table 2-24 DK40i PCB and Power Factors Worksheet Example In the following example, the total DK40i PFs, 10.2 PF for the +5VDC PF category and 26.5 TPSU16 maximum +5VDC PF = 14; Maximum -24VDC PF = 39. Telephone DevicesQuantityX24VDC PF=24VDC Total 2000-series Digital Telephone (any series)...
Page 66
DK40i Configuration Worksheet 2 – System Power Factor Check 2-18Strata DK I&M 5/99 PCB and Power Factor Worksheets See examples on previous pages. Table 2-25 DK40i Telephone/Device Power Factor (Base/Expansion KSU) Table 2-26 Power Factor Worksheet Telephone DevicesQuantity InstalledX-24VDC PF=-24VDC PF Total 2000-series Digital Telephone (any series)X1.0 = Cordless Digital Telephone (DKT2004-CT)X1.0 = 2000-series Electronic TelephoneX2.0 = 3000-series Electronic TelephoneX2.5 = 6000-series...
Page 67
DK40i Configuration DK16/DK16e/DK40/DK40i Component Compatibility Strata DK I&M 5/992-19 DK40i Configuration DK16/DK16e/DK40/DK40i Component Compatibility The Strata DK16 Base KSU cannot be upgraded to a DK16e, DK40 or DK40i and the DK16 Expansion Cabinet is not compatible with the DK16e, DK40 or DK40i. The Strata DK40i is not a modification of the DK40, but rather a completely new system. The DK40i uses the DK40 expansion cabinet. The DK16e can be upgraded to DK40 by changing a ROM chip, but not to a...
Page 68
DK40i Configuration DK16/DK16e/DK40/DK40i Component Compatibility 2-20Strata DK I&M 5/99 Table 2-28 Strata DK16e/DK40i Components Strata DK16e/DK40/DK40i ComponentsCompatible PartDescriptionDK16DK16eDK40DK40i TCOU1A4-Loop CO Line Interface Unit X X X TDDU1A4-DID CO Line Interface Unit X X X TCIU2ACaller ID Interface Unit X X X TSIU1A2-I/O Serial Interface Unit X X X KSTU2A4-Standard Telephone Interface Unit XXXX K4RCU3A, K5RCU1A or K5RCU2A 1 1. For 9~12 DID and/or Tie lines, use K5RCU1A or...
Page 69
Strata DK I&M 5/993-1 DK40i Installation DK40i Installation3 This chapter explains how to install the Strata DK40i system. It includes information on site requirements, wiring diagrams, and step-by-step instructions on how to install the unit(s), the ground wiring, AC power cabling, reserve power (battery backup) cabling, and PCB cabling. Inspection 1. When the system is received, examine all packages carefully and note any visible damage. If any damage is found, do not open the packages. Contact the...
Page 70
DK40i Installation Site Requirements 3-2Strata DK I&M 5/99 Input Power The system requires an input power source of 115VAC ± 10VAC, 50/60 Hz, 15 amps. The AC outlet is recommended to be dedicated and unswitched, with a solid third-wire ground. (See “AC Power and Grounding Requirements” on Page 3-4.) This eliminates interference from branch circuit motor noise or the like, and to prevent accidental power-off. To avoid accidental power turn-off, Toshiba recommends that you do not use an ON/ OFF wall...